Records from 1994 to 2022. Most recent: inspection, 9 February 2022.
Documentation record
Registered dimensions (L × B × D)65.8 ft × 20.1 ft × 7.1 ft
Registered tonnagegross 112 / net 76
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORPORATION · NEVILLE ISLAND PA, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Net Ton
112 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
9 February 2022
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7365216
28 September 2021
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7322439
15 January 2020
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6919600
10 September 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5731686
17 February 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4248089
26 July 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4097492
27 May 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2369772
27 February 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2300451
3 December 2004
MTSA Verification
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2268389
22 May 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2078686
31 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2002974
14 March 1998
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 773998
13 November 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 659100
24 October 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 94711
4 September 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 19404
20 September 1996
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 395703
8 February 1996
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 388090
30 August 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 133296
30 August 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 149837
25 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 102301
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 February 2022
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Fire detection system inoperative. Make repairs as required by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section. As objective evidence, provide TPO with service report.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2022
Resolution: Properly connected loose wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The following electrical safety hazards were identified:
* Breaker panel located in lower engine room missing blank or breaker leaving exposed area within panel.
* Electrical cover for hot water heater element missing leaving wires and connections exposed.
* Dead end wires found in galley area with electrical tape covering wire ends.
* Twist-on wire connections used for baseboard heater with no enclosure.
Repair all identified electrical issues as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 9 February 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. No rails or equivalent protection installed on the stern of the main deck of vessel. Install rails or equivalent on stern as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 9 February 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Approximately 1" of oily water mixtures found in bilges of engine room. Pump out bilges and repair leaks as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: Pumped bilges out
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2022
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Aerosol can of starting fluid found in engine room. Remove flammable products from engine room and store in flammable storage locker as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: Removed starting fluid from engine room
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Air compressor discharge hose wasted. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: Replaced hose with new
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 February 2022
Resolved
Pressure vessel relief valves must be tested in accordance with § 143.245 (Twice in 5 years). No makings or documentation available to indicate pressure relief valves were tested. Provide evidence of testing or replacement of relief valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: Applied tag indicating replacement date
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 9 February 2022
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Vessel Master missing medical certificate. Apply for replacement medical certificate as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: Provided proof of medical certificate