MAURY USCG vessel records
← All vessels

CSCL ASIA

CSCL ASIA is a 2004 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in October 2017, along with 3 deficiencies.

Records from 2016 to 2017. Most recent: inspection, 18 October 2017.

Built
2004
Last inspected
18 October 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 October 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9285976
705721
Flag
HONG KONG
Maury page id
psix-705721

Documentation record

Tonnage as PSIX records it90645 - Convention (Subpart B), Gross Ton
56758 - Convention (Subpart B), Net Ton
101612 - Dead Weight, Ton
134841 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

18 October 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6289575
27 June 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6188185
5 February 2017 ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6082942
23 July 2016 ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5949754
28 March 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840079

Deficiency record · 3

Lifesaving › Line-Throwing Appliances › Lines
Issued 18 October 2017 Resolved
Every line throwing appliance shall be capable of throwing a line with reasonable accuracy.Two line throwing guns had tangled an knotted lines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2017
Resolved 19 October 2017
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 18 October 2017 Resolved
A fixed fire fighting system and alarm system required in this regulation sall be of an approved type and comply with the fire systems safety code. On main fire alarm panel, system is showing a fault in zone 14, on the fourth deck of the engine room.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2017
Resolved 19 October 2017
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 18 October 2017 Resolved
In order to achieve the fire safety objectives in PARA 1, the following functional requirements are embodied in the regulations. The restricted use of combustible materials. Combustible materials were found in the paint locker.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 18 October 2017
Resolution: Deficiency rectified on the spot

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.