Records from 1985 to 2024. Most recent: inspection, 11 January 2024.
Inspection history · 15
11 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7848283
1 November 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7572567
2 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7344040
6 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7297131
4 January 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7119438
10 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7043817
24 April 2019
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6669099
14 September 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4715910
17 June 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3506693
22 February 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2011297
3 April 1996
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1077902
19 September 1995
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1182936
27 January 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 321012
29 January 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 313949
27 June 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 302887
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 January 2024
No resolution recorded
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. COI on this vessel expired on 1/11/2024. The vessel shall be made available for a Coast Guard COI inspection and the vessel is NOT permitted to operate until a valid COI is issued.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 November 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room ventilation louvers in exhaust stack has no means to close. Install means to close ventilation in case of a fire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 22 November 2022
Resolution: Installed removable covers
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 November 2022
Resolved
Each remote fuel shutoff valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Remotes for fuel shutoff valve are not properly labeled indicating how to operate. Provide directions for use as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 22 November 2022
Resolution: Instructions added
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 November 2022
Resolved
The portable fire pump must be self-priming and power-driven. Fire pump on vessel was not self priming. Install on vessel a self priming fire pump or install a foot valve to existing fire pumps suction line.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 22 November 2022
Resolution: Foot valve installed on suction side of fire pump to assist in priming pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical breaker panel in engine room has an opening in the cover. Install missing breaker or a blank to fill hole.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 22 November 2022
Resolution: Breaker installed in opening
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2021
Resolved
Lifebuoys must have the following attachments and fittings: (1) At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Both lifebouys had lifelines attached.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: Lifebuoy added without lifeline attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 October 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. Forward and aft void hatch covers are missing labeling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: Hatches labeled with sharpy
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 October 2021
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. On a new vessel, each pipe that contains vapor, gas, or liquid that has a temperature exceeding 150 °F (65.5 °C) which is within reach of personnel must be insulated where necessary or otherwise guarded to prevent injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: Lagging added to outboard side of engine exhaust.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 October 2021
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. At a minimum, this assessment must consider: (1) The velocity and direction of currents in the area being transited; (2) Water depth, river stage, and tidal state along the route and at mooring location; (3) Prevailing visibility and weather conditions and changes anticipated along the intended route; (4) Density (actual and anticipated) of marine traffic; (5) The operational status of pilothouse instrumentation and controls, to include alarms, communication systems, variation and deviation errors of the compass, and any known nonconformities or deficiencies; (6) Air draft relative to bridges and overhead obstructions taking tide and river stage into consideration; (7) Horizontal clearance, to include bridge transits; (8) Lock transits; (9) Navigation hazards such as logs, wrecks or other obstructions in the water; (10) Any broadcast notice to mariners, safety or security zones or special navigation areas; (11) Configuration of the vessel and tow, including handling characteristics, field of vision from the pilothouse, and activities taking place onboard(12) The knowledge, qualifications, and limitations of crewmembers who are assigned as members on watch and the experience and familiarity of crewmembers with the towing vessels particulars and equipment; and (13) Any special conditions not covered above that impact the safety of navigation. (b) The officer in charge of a navigational watch must keep the navigation assessment up-to-date to reflect changes in conditions and circumstances. This includes updates during the voyage or trip as necessary. At each change of the navigational watch, the oncoming officer in charge of the navigational watch must review the current navigation assessment for necessary changes. (c) The officer in charge of a navigational watch must ensure that the navigation assessment and any updates are communicated to other members of the navigational watch. (d) A navigation assessment entry must be recorded in the TVR, official log, or in accordance with the TSMS applicable to the vessel. The entry must include the date and time of the assessment, the name of the individual making the assessment, and the starting and ending points of the voyage or trip that the assessment covers. Current navigation assessment does not include all elements required.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: NAV Assessment created and implamented to meet requirements
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2021
Resolved
Storage of flammable or combustible products.
(a) Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
(b) If a storage room is provided, it may be any room or compartment that is free of ignition sources.
(c) If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either: (1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or (2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or (3) Another suitable steel container that provides an equivalent level of protection.
(d) A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Flammable and combustible products found improperly stored in machinery spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: combustable products removed from vessel
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 October 2021
Resolved
Hatches and other openings.
(a) All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding.
(b) The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
(c) The master or officer in charge of a navigational watch must ensure all hatches and openings of the hull and deck are kept tightly closed except: (1) When access is needed through the opening for transit; (2) When operating on rivers with a tow, if the master determines the safety of the vessel is not compromised; or (3) When operating on lakes, bays, and sounds, without a tow during calm weather, and only if the master determines that the safety of the vessel is not compromised.
(d) Where installed, all watertight doors in watertight bulkheads must be closed during the operation of the vessel, unless they are being used for transit between compartments; and
(e) When downstreaming, all exterior openings at the main deck level must be closed.
(f) Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition.
Aft void hatch not tightly closed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 October 2021
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 16 October 2019
Resolved
No documented fuel maintenance plan
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 16 October 2019
Resolved
No documented towing grear emergency procedures.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2019
Resolved
Both water lights lanyard not properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2019
Resolved
Semi portable fire extinguishers not properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019
Resolved
Electrical switch boards and distribution panel not properly marked with respective current and voltage ratings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2019
Resolved
Port side emeergency fuel shut off valve does not close completley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 October 2019
Resolved
No overboard fall protectionon vessel stern.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2019
Resolved
Shipboard engine oil pressure gauge not operating.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2019
Resolved
Vessel piping not properly identified and through hull fittings not properly marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2019
Resolved
Vessel not equiped with navigation lights and day shapes appropriate for conditions when not uner command restricted in ability to maneuver or aground.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2019
Resolved 4 January 2021
Resolution: Vessel is in compliance with D8(dp) Policy letter 02-20 in regards to vessels operating on Rivers routes and the application of Rule 27 and 30 Nav light and day shape carriage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 April 2019
Resolved
Galley door that exir=ts to port side has broken pane becoming safety hazard to crew.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 13 November 2019
Navigation
Issued 27 June 1985
Resolved
TWO AMBER TOWING LIGHTS INOPERATIVE AS REQUIRED BY 33USC2024(C)(III)
Condition: Unknown
Due 27 June 1985
Resolved 27 June 1985
Navigation
Issued 27 June 1985
Resolved
AMBER OR WHITE WHISTLE LIGHT NOT OPERATING IN SYNC. WITH WHISTLE AS REQUIRED BY 33USC2034(B)(III)
Condition: Unknown
Due 27 June 1985
Resolved 27 June 1985