MAURY USCG vessel records Sign in
← All vessels

AUBREE TARA

AUBREE TARA is a 2004 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2004, most recently in July 2019, along with 16 deficiencies.

Records from 2004 to 2019. Most recent: inspection, 11 July 2019.

Built
2004
Last inspected
11 July 2019
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH3734
706591
Flag
UNITED STATES
367523460, 367610330 (licence lapsed)
Maury page id
psix-706591

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2004–2019)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 14.0 ft × 7.0 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA STATE ONE MARINE LLC · ANCHORAGE, AK, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 29 July 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH3734MMSI 367610330 · expired · compulsorily equipped · granted 15 March 2014, cancelled 18 May 2024
WDG3192MMSI 367523460 · expired · compulsorily equipped · granted 28 March 2012, cancelled 28 May 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

11 July 2019 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6746600
3 September 2015 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5234879
3 June 2014 COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4877739
19 May 2014 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4862303
17 March 2014 Plan Review "T" Boat
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4817910
23 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4320138
8 December 2011 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4204470
2 August 2011 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4117570
4 December 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3374536
12 June 2008 DAPI Audit · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3297474
4 June 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3227225
20 May 2008 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3220726
6 June 2007 Annual Inspection · Internal Structural Exam · Administrative Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2960696
13 July 2006 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2712748
8 June 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2703961
17 May 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2799465
18 May 2005 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2363289
8 September 2004 Initial Certification · Simplified Stability Test
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2190612

Deficiency record · 16

Electrical › Electric Supply System (service) › Cable
Issued 3 September 2015 Resolved
Ensure wire runs in engine space are properly mounted to overhead with metal grommets every 24".
Due 4 October 2015
Resolved 4 September 2015
Resolution: Issue corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 September 2015 Resolved
Ensure all combustible engines in engine space automatically turn off when fireboy system is activated.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2015
Resolved 3 September 2015
Resolution: Issue corrected on the spot. Issue resolved due to a poorly connected electrical connection. Corrected on the spot.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 3 June 2014 Resolved
Prove proper operation of automatic engine shut-down for pre-engineered fire fighting system solenoid for Starboard MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2014
Resolution: Corrected on the spot. Discovered leaky turbo gasket which melted electrical connection to solenoid for shut down - system worked as design after correcting issue. Steps taken to prevent happening in future w/ exhaust lagging around turbo.
Engineering › Bilge Water Management System › Valve
Issued 23 May 2012 Resolved
Install positive shutoff valves at hull penetration for each electrical submersible bilge pump discharge hose (46CFR182.520(e)(7)).
Due 23 June 2012
Resolved 29 August 2012
Resolution: New valves installed on all electric bilge pump lines
Documentation › Certificates/Documents › Stability Letter
Issued 7 December 2011 Resolved
Total passengers allowed onboard is reduced to 29 total passengers utilizing the weight ratio method to comply with the Final Rule on passenger weight standards that became effective on December 1, 2011. Owner/Operator must submit a "Certification of Stability Compliance" to the [name withheld].
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 December 2011
Resolution: Vessel sent "Certification of Stability Compliance" to the [name withheld] COC and issued new stability addendum, vessel is in compliance with new weight standards.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 July 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 2006
Resolved 14 July 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 July 2006 Resolved
While conducting DAPI audit, it was noted that two current employees were missing from the random pool. Owner, PETE HADDELL advised of deficiency. Will amend list asap thru Worksafe.
Condition: Unknown
Due 21 July 2006
Resolved 17 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Seal wire runs throught Engine Room bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 September 2004 Resolved
Install hatch keepers on all hatches.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Communications › Visual Communication › Warning Sign (gangway)
Issued 8 September 2004 Resolved
Post all placards
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 September 2004 Resolved
Install F/O remote handle protection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 September 2004 Resolved
Label F/O remotes " push to close"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 September 2004 Resolved
Provide 2004 list of all emplyees from drug consortium.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Engineering › Fuel Oil Service System › Piping
Issued 8 September 2004 Resolved
Provide glass with protection rods on F/O sight glass.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 September 2004 Resolved
Mount BIII extinguisher.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 September 2004 Resolved
Conduct MOB/Abandon ship/Fire drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 8 September 2004

Ownership record