This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11191 - Convention (Subpart B), Gross Ton 4931 - Convention (Subpart B), Net Ton 16800 - Dead Weight, Ton 22438 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
3 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
7 October 2016ISPS II Exam · Ballast Water Examination · Joint Vessel Security Verification (Massena only) · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6020009
1830 Each vsl vapor connection flange face must have a permanent study projecting outward that must be located at eh top of the flange face midway between boltholes and in line with the bolthole pattern. PSCO observed the stud on the VC line was not permanently affixed to the flange face. 46CFR39.2001(j) 40bc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2016
Resolution: Proper documentation from recognized organization has been received. Attached to MISLE activity #5872367
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 7 March 2016Resolved
1870 A water-spray system of sufficient capacity shall be provided to blanket effectively the area surrounding the loading manifold, exposed deck piping associated with product handling. PSCO observed numerous deck water spray nozzles that had no pressure or very little pressure. Prior to carrying any cargo that required the use of the deck water spray it must be operational. IBC Code 15.8.2.9 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Deficiency rectified