Records from 2006 to 2026. Most recent: inspection, 18 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 27
18 March 2026
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8328167
5 November 2025
COC-CVE Annual · PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8264632
19 June 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8162581
15 May 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8153232
14 May 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8134965
14 May 2025
PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8182304
12 May 2025
PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8133268
22 April 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8117347
22 April 2025
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8117365
17 April 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113477
15 November 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8034436
5 September 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7997197
22 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7963786
20 July 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7962451
28 May 2024
COC-CVE Quarterly
Type not classified · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7921734
21 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7916234
14 November 2023
COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7824419
8 April 2019
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6657936
27 March 2019
ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6650165
27 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6587350
19 November 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6583208
10 October 2018
MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · COC-CVE Annual · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6557306
2 April 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6381790
4 October 2017
MARPOL Annex VI Survey · ISPS II Exam · MARPOL Annex V Examination · COC-CVE Annual · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6280199
22 December 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6061487
21 November 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045283
8 November 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6037442
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 May 2025
Resolved
Every crew member with an assigned emergency duties shall be familiar with these duties before voyage begins. Stairway Guides in aft passenger stairway zone 7 all decks except 11, 12 lacked the knowledge required for emergency.
74SOLAS 20 III/19.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 May 2025
Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed hanging laundry, shoes and dirty laundry bags in an unayyended housekeeping cart on deck 3, blocking escape paths.
74SOLAS 20 II-2/13.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2025
Resolution: Resolved
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 May 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.. PSCO observed a missing spanner wrench at fire station 04-6-45.
74SOLAS 20 II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2025
Resolved
Cabin doors in "B" class divisions shall be of a self-closing type. Hold-back hooks are not permitted. PSCO observed three cabins on deck three that were propped open and unattended.
74SOLAS II-2/9.4.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2025
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom.PSCO observed several plastic garbage cans on deck 3 and 4, specifically in the main laundry space and in the vicinity of the gangway area.
74 SOLAS 20 II-2/4.4.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 May 2025
Resolved
74SOLAS 20 II-2/9.1.3 10C 07103
The purpose of this regulation is to contain fire in the space of origin. For this purpose, the following functional requirements must be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Pipe penetration for fuel oil tank level sensor in emergency generator room was provided with spacers but not with fire/smoke prevention compound installed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 May 2025
Resolved 12 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, except those for emergency escape trunks, shall be capable of remote release from the continuously manned central control station, either simultaneously or in groups, and shall be capable of release also individually from a position at both sides of the door. PSCOs observed galley roller shutter fire door at Top Side Grill, deck 12, the center one of three, that failed move or attempt to close after activation of local release.
74 SOLAS 20 II-2/9.4.1.1.5.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2024
Resolved 15 November 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 November 2024
Resolved
A general emergency alarm system complying with the requirements of paragraph 7.2.1 of the Code shall be provided and shall be used for summoning passengers and crew to muster stations and to initiate the actions included in the muster list. The system shall be supplemented by either a public address system complying with the requirements of paragraph 7.2.2 of the Code or other suitable means of communication. Entertainment sound systems shall automatically be turned off when the general emergency alarm system is activated. PSCOs observed that sound systems within the arcade area (several arcade machines) continued to make noise while the public address system was activated.
74 SOLAS 20 III/6.4.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2024
Resolved 15 November 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or
persons on board. While inbound to Port Canaveral the ship reported a hydraulic leak from steering motor pump #4 on the port side Azipod, leading to the reduction of the vessel's speed and the motor being isolated from the system for repairs.
74 SOLAS 20 I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 31 July 2024
Resolution: DNV class report was received by the office with statement that the #4 pump was replaced and all repairs were satisfactorily completed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 November 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use...PSCO observed a soft patch temporary repair on #1 FP topping off pump piping. 74 SOLAS 20 II-2/14.2.1.2
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2023
Resolved 17 November 2023
Resolution: Section of pipe has been renewed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 November 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures, remote-released sliding or power-operated doors shall be equipped with an audible alarm that sounds at least 5s but no more than 10s after the door is released form the central control station and before the door begins to move and continues sounding until the door is completely closed. PSCO observed WTD 1-5-03 and WTD 1-5-04 did not audibily alarm when closed remotely. 74 SOLAS 20 II-2/9.4.1.1.5.10
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2023
Resolved 17 November 2023
Resolution: Repairs carried out to the satisfaction of the USCG.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 November 2023
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consst of a door-latching mechanism incoperating a device that releases the latch upon application of a for in the direction of escape flow. Excessive amount of twist locks in category 8 spaces to include lounges, gym, child care area, restaurants, and throughout upper decks. Areas that have been updated during the vessel's latest refurbishment have had the locks removed, but the majority of the category 8 spaces on the ship still have the twist locks. Additionally, the height of the lock above the ground is inconstant, being far higher in the child care area than the other spaces. 74 SOLAS 20 II-2/13.3.2.6.2
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2023
Resolved 17 November 2023
Resolution: Twist locks are to be removed from the listed spaces by 30NOV2023.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 November 2023
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. If electric illumination is used, it shall be supplied by the emergency source of power and it shall be so arranged that the failure of any single light or cut in a lighting strip will not result in the marking being ineffective. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Emergency exit signage from spa reception area facing the wrong direction. Additionally, low location lighting on the other side of the door indicates exit from adjacent place that is not in emergency escape plan. 74 SOLAS 20 II-2/13.3.2.5.1
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2023
Resolved 17 November 2023
Resolution: Emergency exit signage corrected by crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure.74 SOLAS 20 II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2023
Resolved 15 November 2023
Resolution: Cleared while team on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2019
Resolved
Waste receptacles shall be constructed of non-combustible materials. Numerous combustible waste receptacles found throughout the ship. Deck 7 aft port side, casino office, main laundry and crew galley. 74 SOLAS (14 Cons) II-2/4.2
Action required: 10 - Deficiency Rectified
Due 1 April 2019
Resolved 1 April 2019
Resolution: All combustible waste receptacles were removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 April 2019
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Safety officer and on scene fireman could not demonstrate release procedures for local application fire systems. 74 SOLAS (14 Cons) III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 8 April 2019
Resolution: Vessel provided documentation of training for crew members.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2019
Resolved
Furniture in stairway enclosures shall be limited to seating. Combustible materials found stowed throughout the ship in designated category 2 spaces. 74 SOLAS (14 Cons) II-2/5.3.3
Action required: 10 - Deficiency Rectified
Due 1 April 2019
Resolved 1 April 2019
Resolution: Combustible materials were removed to proper stowage locations.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 8 November 2016
Resolved
0960-Means of Escape- Means of escape shall be marked by lighting or photoluinescent strip indicators. Low location lighting extinguished in several areas to include foward passenger stairway at deck #7, La Cucina, Deck #11 Zone #5 starboard side. 74 SOLAS (2014 Cons) CH II-2/Reg.13.3.2.5.1; 16a
Action required: 705 - Other - as specified
Due 25 December 2016
Resolved 22 December 2016
Resolution: see class report attached
Fire Fighting › Structural - B Class Divisions › Doors
Issued 8 November 2016
Resolved
0750-Fire Prevention- Doors and door frames in "b" class divisions and means of securing them shall provid a metho of closure which shall have resistiance to fire equivalent to that of the divisions. B-15 class door on deck #12 that proviedes acces to galley from Teen Center will not close. 74 SOLAS (2014 Cons) CH. II-2/Reg. 9.4.1.2.1; 16a
Action required: 705 - Other - as specified
Due 25 December 2016
Resolved 22 December 2016
Resolution: See class report attached.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 November 2016
Resolved
0715-Detection-Detectors fitted in cabins, when activated, shall also emitt an audible alarm. Cabin smoke detectors do no emit an auidble alarm. Procedures are in place to emeporarily meet the intnet of the regulation. 74 SOLAS (2014 Cons) CH. II-2/Reg.7.5.2; 16a
Action required: 705 - Other - as specified
Due 25 December 2016
Resolved 22 December 2016
Resolution: Def was issued in error see class explaination attached.