Records from 2006 to 2023. Most recent: operational control imposed, 26 July 2023.
Documentation record
Registered dimensions (L × B × D)44.3 ft × 12.8 ft × 5.4 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROAMER BOAT COMPANY · HOLLAND MI, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOLLAND, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
26 July 2023
Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7752920
6 February 2020
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6903909
10 September 2018
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6537664
21 August 2018
Uninspected Other
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6519850
3 October 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6027976
11 August 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5987208
3 September 2013
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4704422
15 November 2012
Risk-based Targeted Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4485277
14 December 2011
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4208149
5 April 2006
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2617403
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 July 2023
No resolution recorded
Vsl op w/out COI. Vsl issued COTPO & LOW. Must have CG inspection to remove COTPO.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018
Resolved
Both required lifebuoys were deteriorated, not properly marked and missing required equipment, replace both lifebuoys, provide line on one and float lights for both, to be mounted where accessible by crew on both side of vessel.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 September 2018
Resolved
Vessel does not have an inflatable liferaft (ILR) with Solas B pack as required for operation on Great Lakes. Provide properly mounted ILR prior to operation outside the Limited Geographical area of Lake Charlevoix.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2018
Resolved
Life Jackets do not have PFD lights or whistles as required. Provide approved whistles and lights for each life jacket, to be completed prior to operation.
Condition: Improper Installation
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 10 September 2018
Resolved
All work vests are not fitted with PFD lights as required. Ensure an approved PFD light is fastened to each work vest, prior to operation and before 10OCT2018.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 September 2018
Resolved
Work skiff used as survival craft is unsuitable; structural supports are fractured and hull is not marked with vessel name, hailing port and number of persons capacity, to be corrected prior to operation and before 10OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 10 September 2018
Resolved
EPIRB is not maintained as required and is mounted improperly in location likely to impede float free operation. Provide current NOAA registration, apply valid registration decal on EPIRB; Replace expired Hydrostatic Release Unit and re-mount EPIRB above the wheelhouse in a manner that it will float free if the vessel sinks, to be completed prior to operating more than 3 miles from shore and before 10OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 September 2018
Resolved
Required distress signals were expired and were not in a properly marked watertight container. Provide approved distress signals appropriate for operating route prior to operating and before 10OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 September 2018
Resolved
Required immersion suits were not marked or equipped as required. Mark each survival suit with the vessel name and ensure each is fitted with an approved whistle and PFD light, to be corrected prior to operating outside the Lake Charlevoix Limited Geographical Area and before 10OCT2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 September 2018
Resolved
Vessel has no fire pump, piping or hose as required. Install fire pump, piping, hydrant and hose in accordance with a proposal acceptable to the OCMI, prior to operating outside the Lake Charlevoix Limited Geographical Area and before 01MAY2019.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2018
Resolved
Vessel has no fire axe as required. Provide and mount a fire axe at a location readily accessible from the vessel exterior, to be completed prior to operating and before 10OCT2018.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 September 2018
Resolved
Vessel's installed fire detection and alarm system must be USCG approved or listed by a Nationally Recognized Testing Laboratory. The design and installation must be inspected and certified by an acceptable registered professional engineer or a NICET Level IV technician. This must be completed prior to operating outside the Lake Charlevoix Limited Geographical Area and before 01MAY2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2018
Resolved
Required Towing Vessel Record (TVR) and the entries required by section 140.915 were not available. Provide an acceptable TVR and initiate the required recordkeeping before 10OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 September 2018
Resolved
Owner/Operator has not established a Drug and Alcohol Testing Program as required. Establish and provide proof of a fully implemented Drug and Alcohol Testing Program prior to operating and before 10OCT2018.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 September 2018
Resolved
Vessel name and hailing port not marked on stern as required. Mark vessel name and hailing port on stern in as specified in 46 CFR 67.123, before 10OCT2018.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 6 February 2020
Resolution: Vessel determined not to be subject to Sub. M compliance.