MAURY USCG vessel records Sign in
← All vessels

VAGABOND

VAGABOND is a freight ship. The Coast Guard has recorded 38 inspections since 2000, most recently in October 2008, along with 91 deficiencies — 3 with no resolution recorded — and 8 operational controls.

Records from 2000 to 2008. Most recent: inspection, 30 October 2008.

Built
Not recorded
Last inspected
30 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7367380 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO-3800
Flag
PANAMA
—
Maury page id
psix-7084

Inspections, by type

…with no type recorded17
Years with a record 8 calendar years (2000–2008)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
725 - Convention (Subpart B), Gross Ton
217 - Regulatory (Subpart C or D), Net Ton
299 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

30 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3354297
28 June 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2694568
6 June 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2683087
5 May 2006 Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2640366
1 March 2006 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2593796
14 December 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2551363
28 September 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2489365
16 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2494135
13 September 2005 Annual Inspection · ISPS III Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2489357
11 August 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2459128
1 July 2005 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2409357
25 June 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2401978
18 March 2005 PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2312411
18 March 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2313532
4 March 2005 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2303274
4 March 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2303707
21 January 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2278657
7 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2189287
7 August 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2158854
6 August 2004 PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2157290
23 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2142458
30 January 2004 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1961924
23 July 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1853270
18 July 2003 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1849961
16 May 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1795051
18 February 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1745704
5 February 2003 MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1739732
20 August 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1663812
17 July 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1646541
28 January 2002 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1481607
10 August 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 292985
29 May 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 290559
24 May 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 290429
22 May 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 639864
19 May 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 290262
23 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 289404
10 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288971
12 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278945

Deficiency record · 91

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 June 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Due 9 July 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04340 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 June 2006 Resolved
33U.S.C.1321(j)(5)(D)(ii)-The NTVRP does not identify a qualified individual, provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC and the oil spill removal organization. 33U.S.C.1321(j)(5)(D)(iv)-The NTVRP does not address all applicable drill/exercise frequencies
Due 9 July 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04340 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 4 May 2006 Resolved
Vessel must provide original of ISM Document of Compliance. Vessel does have a copy of thier current DOC onboard. Until original is provided keep copy of current document onboard.
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 5 May 2006
Communications › Radio Communications › EPIRB
Issued 4 May 2006 Resolved
Replace existing EPIRB with new appliance with current battery.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2006
Resolved 5 May 2006
Engineering › Steering Gear System › Pump
Issued 4 May 2006 Resolved
Repair emergency steering system. Unit must function properly as designed with rudder response occurring within time limit specified by manufacturer.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2006
Resolved 5 May 2006
Documentation › Certificates/Documents › International Load Line Certificate
Issued 13 September 2005 Resolved
Update CCSSC record of equipment information 2.1.1 stability, 2.1.2 Loadline, 2.2.1 main engine and EPIRB details.
Action required: 705 - Other - as specified
Due 27 September 2005
Resolved 28 September 2005
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 13 September 2005 Resolved
Renew engine room generators tachometer.
Action required: 705 - Other - as specified
Due 27 September 2005
Resolved 28 September 2005
Engineering › Steering Gear System › Pump
Issued 13 September 2005 Resolved
Prove proper operation of the steering gear unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2005
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 13 September 2005 Resolved
Prove proper operation of the firesuit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2005
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 13 September 2005 Resolved
Provide a DOC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2005
Navigation › Piloting/Steering › Marine Charts
Issued 13 September 2005 Resolved
Update charts and light list. To the satisfaction of a Coast Guard inspector.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 September 2005
Resolution: Received fax of class report from agent.
Construction/Loadline › Structures › Superstructure
Issued 1 July 2005 Resolved
Replace broken window in wheelhouse near aft door to the satisfaction of a Coast Guard Inspector or Flag.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 12 August 2005
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 18 March 2005 Resolved
Vessel has changed operators and not updated their COFR to reflect the change
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2005
Resolution: def corrected
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 18 March 2005 Resolved
Provide evidence from Panama that vessel is elgible to be operated under the provisions of the Code of Safety fo Caribbean Cargo Ships. The ITC and Registry list the gross tonnage as 725. The CCSC certificate states the vessel is 299.71 GT. Provide evidence that vessel is measured with correct regulatory and International standards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2005
Resolution: Recieved documentation that states "the Government of Panama recognizes the reconcilliated or national tonnage which is 299.71 because of this reason, the IOPP does not apply to the mentioned vessel..."
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 March 2005 Resolved
Provide evidence of satifactory regulatory dry dock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 March 2005 Resolved
Provide updated CCSSC and Supplement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 4 March 2005 Resolved
Updarte charts
Action required: 15 - Rectify deficiencies by next port
Resolved 7 March 2005
Lifesaving › Launching Appliances › Release Mechanism
Issued 4 March 2005 Resolved
Renew EPIRB hydrostatic release
Action required: 15 - Rectify deficiencies by next port
Resolved 4 March 2005
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 4 March 2005 Resolved
Renew anchor
Action required: 15 - Rectify deficiencies by next port
Resolved 7 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 August 2004 No resolution recorded
Complete services of Fixed Fire Fighting Services.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Rcvd class report
Navigation › Piloting/Steering › Marine Charts
Issued 6 August 2004 No resolution recorded
Provide updated charts.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Rcvd class report
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 6 August 2004 No resolution recorded
Update compas deviation IAW CCSSC 6.4.2.
Action required: 15 - Rectify deficiencies by next port
Resolution: Rcvd Class report.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 August 2004 Resolved
Make repairs to breaker box in second officers cabin.
Action required: 705 - Other - as specified
Due 20 August 2004
Resolved 7 August 2004
Resolution: Rcvd class report.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 August 2004 Resolved
Remove oxygten/acetylene from accomodation area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2004
Resolution: Rcvd class report.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 6 August 2004 Resolved
Clean or repair tooven prior to its use.
Action required: 705 - Other - as specified
Resolved 7 August 2004
Resolution: Rcvd class report.
Engineering › Steering Gear System › Linkage
Issued 6 August 2004 Resolved
Make repairs and prove operations of steering machinery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2004
Resolution: Rcvd class report.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 6 August 2004 Resolved
Make repairs to prove operation of emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2004
Resolution: Rcvd class report.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 6 August 2004 Resolved
Provide fire suit IAW 3.11.1 of CCSSC code.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 August 2004
Resolution: Rcvd class report.
Engineering › Thrusters › Motor
Issued 6 August 2004 Resolved
make repairs and prove operations of bow thruster controls/alarms IAW CCSSC chapter 2 Part D.
Action required: 705 - Other - as specified
Resolved 7 August 2004
Resolution: Rcvd class report.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 6 August 2004 Resolved
Provide lilfejackets IAW 4.7 of Annex 3 of CCSSC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2004
Resolution: Rcvd class report.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 23 July 2004 Resolved
FAILURE TO SUBMIT ANOA W/IN 24 HOURS. SUBMIT LOU, DEPART U.S. PORT AND SUBMIT PROPER ANOA.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 July 2004
Resolution: Received Letter of Undertaking from Brown & Ubarri Attorneys at Law.
Construction/Loadline › Structures › Door
Issued 23 July 2004 Resolved
REPAIR DOOR FRAME LEADING TO FOSCLE FROM WINDLASS DECK TO THE SATISFACTION OF FLAG/CLASS SURVEYOR AND SUBMIT REPORT TO USCG INSPECTOR. DOOR FRAME HAD APPROX. (2) HOLES. CROP AND RENEW AND CHECK GASKET.
Action required: 705 - Other - as specified
Due 22 August 2004
Resolved 17 August 2004
Resolution: Received Flag authorized surveyor report attesting to repairs.
Documentation
Issued 18 July 2003 Resolved
Provide original or certified copy of Certificate of Registry
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2003
Navigation
Issued 18 July 2003 Resolved
Update navigation charts
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2003
Communications
Issued 18 July 2003 Resolved
Make repairs to NAVTEX receiver iaw 5.7 of annex 3 CCSSC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2003
Fire Fighting
Issued 18 July 2003 Resolved
Provide evidence of service of bow thruster and engine room fixed extinguishing system. Until corrected, engine room to be continuously manned with crew member and means to communicate and means to extinguish a fire. Crew member to amke adequate rounds of bow thruster.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2003
Lifesaving
Issued 18 July 2003 Resolved
Renew starboard buoyant smoke, auto activation signal.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2003
Navigation
Issued 18 July 2003 Resolved
Make repairs to port and starboard gyro repeaters.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2003
Engineering
Issued 18 July 2003 Resolved
Make repairs to aft steering station thruster controls.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2003
Engineering
Issued 18 July 2003 Resolved
Make repairs to number two electrical generator and bow thruster prime mover iaw CCSSC Chapter 2, Part D.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2003
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 16 May 2003 Resolved
Contacted NPFC and determined vsl not in substantial compliance. Vsl denied entry into U.S. Waters
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 19 May 2003
Construction/Loadline › Markings
Issued 5 February 2003 Resolved
Port and Stbd Deck line not visible. Paint Deck line as stated on Load line Certificate. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Due 14 February 2003
Resolved 15 February 2003
Resolution: Deck line repainted
Electrical › Electrical Distribution System (service)
Issued 5 February 2003 Resolved
Electrical power panel in dry storage needs secured. Repair/Replace cover as per CCSSC 2.32.1.3 LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 14 February 2003
Resolved 15 February 2003
Resolution: Electrical Power panel secured, cover repaired
Electrical › Lighting (service)
Issued 5 February 2003 Resolved
Repair/Replace lighting fixture in passageway leading into the engineroom. Lighting fixture does not have any bulbs and in wasted. CCSSC 2.31.1.3 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 14 February 2003
Resolved 15 February 2003
Resolution: Replaced bulbs and installed plastic safety shield.
Electrical › Lighting (service)
Issued 5 February 2003 Resolved
Starbord light fixture in aft steering missing globe. Replace/Repair. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 14 February 2003
Resolved 15 February 2003
Resolution: Lens and cover replaced
Electrical › Electrical Distribution System (service)
Issued 5 February 2003 Resolved
Duplex receptacle in aft steering falling out of junction box. Replace/Repair. CCSSC 2.31.1.3 LEGACY COMPONENT DESC: Neutral Bus
Condition: Improper/Lack of Maintenance
Due 14 February 2003
Resolved 15 February 2003
Resolution: Receptical properly secured.
Electrical › Electrical Distribution System (service)
Issued 5 February 2003 Resolved
Replace/Repair missing dryer plug in laundry. Wires are hanging out of bulkhead. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 14 February 2003
Resolved 15 February 2003
Resolution: New Dryer plug installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 February 2003 Resolved
Secure/remove old batteries from bow thruster compartment.
Due 14 February 2003
Resolved 15 February 2003
Resolution: Batteries removed and desposed of.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 5 February 2003 Resolved
Secure CO2 fire extinguisher located in passageway leading to the engine room. LEGACY COMPONENT DESC: Mounting Bracket
Due 14 February 2003
Resolved 15 February 2003
Resolution: Installed proper securing straps on CO2 fire extinguisher.
Deck/Cargo › Ballast
Issued 5 February 2003 Resolved
Stbd #3 ballast tank has numerous pin holes located on the inboard side. Make repiras as needed. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 26 February 2003
Resolved 25 February 2003
Deck/Cargo › Ballast
Issued 5 February 2003 Resolved
#3 Port and Stbd ballast tank manhole covers leak. Repair/Replace as needed. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 26 February 2003
Resolved 27 February 2003
Engineering › Steering Gear System
Issued 5 February 2003 Resolved
Port and Stbd Rudder post supports have numerous cracks where they attach to the aft bulkhead/ballast tank, causing water to leak when tank is in use. Make proper repiars to bulkhead and supports. LEGACY COMPONENT DESC: Bracket/Clamp
Action required: 705 - Other - as specified
Due 14 February 2003
Resolved 15 February 2003
Resolution: Veed out old welds, re-welded stay braces to plates on fwd bulkhead of after peak tank.
Construction/Loadline › Hull
Issued 5 February 2003 Resolved
Flagstate to attest to the repairs made in after steering hull Stbd side. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 14 February 2003
Resolved 15 February 2003
Resolution: Examined repairs previously carried out to the vessel''s stbd quarter and found them to be in order.
Construction/Loadline › Markings
Issued 17 July 2002 Resolved
Repaint load line in white, yellow or any contrasting color. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Due 17 August 2002
Resolved 20 August 2002
Resolution: RECEIVED VIA FAX STATEMENT FROM MASTER STATING THAT THE DEFICIENCY HAS BEEN CORRECTED.
Navigation › Emergency Steering
Issued 17 July 2002 Resolved
Vessel to prove proper operation of emergency steering system as per CCSS code 2.38.3.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2002
Resolved 17 July 2002
Resolution: Vessel provided a FLAG Surveyor certification of required repairs to the steering system.
Personnel › Manning/Qualifications
Issued 28 January 2002 Resolved
Vessel found to be sailing short one deck-hand. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2002
Resolution: Additional crewmember brought onboard.
Unknown
Issued 19 May 2001 Resolved
Make repairs to ships horn.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
ENSURE DANGEROUS CARGO IS PLACARDED.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROPERLY SEAL WTB IN VICINITY OF FORWARD ENGINE ROOM WTD.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE FIRE AXE.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVE OPERATION OF OVERSPEED DEVICES.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PRIOR TO ITS USE, MAKE REPAIRS AND PROVE OPERATION OF THE STEERING STATION IN THE VICINITY OF THE PORT LIFEBOAT.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
UPDATE DEVIATION TABLE.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
UPDATE CHARTS AND PUBLICATIONS.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE WEATHER TIGHT BELL HOUSING ON PORTSIDE FOREPEAK VENT.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PRIOR TO CARRYING DANGEROUS CARGO PROVIDE CLASS OR FLAG DOCUMENT AUTHORIZING CARRAIGE OF DANGEROUS CARGO.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE TWO MEANS TO COMMUNICATE BETWEEN ENGINE ROOM AND BRIDGE.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
MAKE REPAIRS AND PROVE OPERATIONS OF LOW AIR PRESSURE ALARM.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE SERVICE REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE A MEANS OF TELLING DIRECTION OF PROP IAW CCSSC 2.6.2.37.1.8
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE PLANS IAW CCSSC 1.8
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE EVIDENCE OF FLAG APPROVAL OF VESSEL ARRANGEMENT WITH RESPECT TO CCSSC 3.24.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
RENEW STARBOARD RUDDER AS ORIGINAL. PROVIDE FLAG REPORT ATTESTING RUDDER REPAIRS ARE SATISFACTORY PRIOR TO DEPARTING ST. CROIX.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Unknown
Issued 19 May 2001 Resolved
CONDUCT FIRE AND LIFEBOAT DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTING ST. CROIX.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Documentation
Issued 19 May 2001 Resolved
Provide onboard IOPP Certificate IAW CCSSC Certificate.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Documentation
Issued 19 May 2001 Resolved
Provide on board stability letter.
Condition: Unknown
Due 19 June 2001
Resolved 31 May 2001
Unknown
Issued 19 May 2001 Resolved
PROVIDE EMERGENCY STOP DEVICE ON BRIDGE.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Documentation
Issued 12 May 2000 Resolved
DECK OFFICERS NEED HAZMAT ENDORSEMENT FOR LICENSES STCW 78 II/III
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Deck/Cargo
Issued 12 May 2000 Resolved
THRUSTER ENGINE LEAKS OIL EXCESSIVELY. CCSSC CHAP II
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Documentation
Issued 12 May 2000 Resolved
PROVIDE ORIGINAL CERTIFICATES FOR SHIP VICE FAX'ED COPIES.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 12 May 2000 Resolved
PROVIDE BATTERY FOR EPIRB (EXPIRED)
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 12 May 2000 Resolved
PROVIDE 04 LIFE JACKETS TO COMPLY WITH CCSSC CERTIFICATE.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Deck/Cargo
Issued 12 May 2000 Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33CFR 155/156
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 12 May 2000 Resolved
PROVIDE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH ANNEX.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Engineering
Issued 12 May 2000 Resolved
INSTALL 30 MESH FLAME SCREENS ON ALL FUEL VENTS. 46 CFR 30. NOTED WELDING IN VIC. OF FUEL VENTS. HIGHLY RECOMMEND ENFORCEMENT OF FLAME SCREEN POLICY.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 12 May 2000 Resolved
PROVIDE FIXED FIRE FIGHTING SYSTEM. CURRENT SYSTEM NOT SERVICED AND COMPLETLY INOPERABLE. (EMPTY BOTTLES, BURNT FLEXLOOPS, NO INSTRUCTIONS, NO ACTIVATION SYS ECT...)
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Electrical
Issued 12 May 2000 Resolved
PROVIDE BATTERY BOXES FOR BATTERIES IN ENGINE ROOM AND BOW THRUSTER. CCSSC 2
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 12 May 2000 Resolved
PROVIDE TRAINING TO ENTIRE CREW ON EMERGENCY SIGNALS (ABANDON SHIP, FIRE ECT..) CCSSC 4. AND 4.16,17
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Electrical
Issued 12 May 2000 Resolved
INSULATE AND PROPERLY SPLICE ELECTRICAL WIRES AT AFT STEERING, WELDING MACHINE IN ENGINE ROOM AND MAIN CONDUIT TO FIRE PUMP.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 12 May 2000 Resolved
FIX START/STOP BUTTON FOR FIRE PUMP. CCSSC 3.4AND 3.5
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 12 May 2000 Resolved
MAIN WATER TIGHT DOOR TO ENGINE ROOM FM MESS DECK NOT FLUSH WHEN DOGGED.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000

Ownership record