← All vessels
PRIVATEER
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named PRIVATEER
PRIVATEER is a 1976 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2006, most recently in November 2025, along with 78 deficiencies and 2 operational controls.
Records from 2006 to 2025. Most recent: inspection, 18 November 2025.
- Built
- 1976
- Last inspected
- 18 November 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 78 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1160782
WDD5591
708442
Flag
UNITED STATES
367160640
Maury page id
psix-708442
Inspections, by type
…with no type recorded2
Years with a record
16 calendar years (2006–2025)
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)41.0 ft × 13.0 ft × 5.0 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLANDER YACHT CORPORATION · IRVINE, CA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ7777MMSI 367160640 · active · compulsorily equipped · granted 5 February 2026, expires 5 February 2036
WDD5591MMSI 367160640 · cancelled · voluntarily equipped · granted 3 December 2016, cancelled 16 January 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 32
18 November 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8260490
26 November 2024
Deficiency Check · Hull Examination · Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8040160
21 November 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8034459
26 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7870159
15 November 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7595461
14 November 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7593978
14 December 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367206
24 August 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7295689
16 November 2020
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7096496
3 July 2020
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6999683
10 December 2019
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6871466
5 December 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6867976
19 December 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6598007
3 December 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6589315
13 November 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6308045
6 December 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6053339
15 November 2016
Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6041033
3 December 2015
Administrative Inspection · Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5761549
6 January 2012
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4220196
8 December 2010
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3907186
15 July 2009
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3535353
4 May 2009
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3467230
1 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437163
12 December 2008
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373719
12 October 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3343630
10 December 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3112632
16 January 2007
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2998354
9 January 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2852815
8 January 2007
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2852478
4 January 2007
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2850115
3 January 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2850125
19 July 2006
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2718126
Deficiency record · 78
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025
Resolved
Connections must be made to battery terminals with permanent type connectors.
Engine room battery bank was found to have a loose terminal connection.
46 CFR 183.350(d)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 November 2025
Resolved
Each...survival craft...on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway.
Life float was found to have numerous holes around the exterior body.
46 CFR 185.700(a)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 November 2025
Resolved
Each buoyant apparatus must have Type II retroreflective material.
Life float had insufficient retroreflective material.
46 CFR 160.010-4(p)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
At each...inspection for certification of a vesseL...be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings...and their attachment to the hull structure.
The port aft-most stanchion was found to be up-rooted from the hull.
46 CFR 177.900(b)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2025
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant.
The water light battery in the life float was found to be expired.
46 CFR 180.70(d)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2025
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant.
The water light battery in the life ring was found to be expired.
46 CFR 180.175(f)(4)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Radio station authorization did not have the appropriate radio service for vessel type.
46 CFR 184.502
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI observed aft compartment drawer support right above the steering pulley to be loose.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 November 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed water leak in the overhead of the engine room compartment directly above the engine where the binnacle is mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. MI observed the fire extinguisher at the operating station was a 5BC. Replace 5BC extinguisher with a 10BC to meet the requirements stated on COI.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 November 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall...have the vessel read for inspections of the hull structure and its appurtenances, including: on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel's mizzen boom topping lift tang was observed shearing into the shackle, procure new parts and repair to MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 November 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve… MI found the retro tape on the life float to be wasted. Replace retro to the satisfaction of the MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Discovered one life jacket damaged from electrical burns. Vessel to replace damaged life jacket.
46 CFR 180.71(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel to install or replace guards on electrical equipment, to the satisfaction of the Coast Guard Marine Inspector, in the following locations: terminal board in STBD storage compartment, electrical box in PORT storage compartment, below deck in main cabin.
46 CFR 183.200(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 November 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Vessel to repair or replace faulty main bilge pump to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 182.520(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel to repair or replace faulty shaft packing gland to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 182.200(a)
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 December 2021
Resolved
On a nonmetallic vessel, the enclosures and frames of electric equipment must be bonded together to a common ground by a normally non-current carrying conductor. Grounding wire on battery terminal needs to be replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2021
Resolved
Connections must be made to battery terminals with permanent type connectors. Wing nuts were present on the battery terminal connections.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 December 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit was expired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 August 2021
Resolved
Rail courses or the equivalent must be installed between a top rail and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except: on the passenger deck of a vessel on an excursion trip the following must be installed: bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches) Vessel's course height is equivalent to 12 inches
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2020
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Lanyard is significantly longer than 6 feet.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2020
Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. The items contained in first-aid kit shall be listed in Table 160.041-4(b). Eye dressing packets are expired and must be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring life buoy grab line is severely deteriorated.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Float-free link is missing the identification tag.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life float lines and painter are deteriorated and not stowed to be able to run freely.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Water light line is severely deteriorated.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 December 2019
Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. Loose fire proof lagging on engine exhaust piping was discovered.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 December 2019
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Loose insulation in the starboard overhead of engine room space was discovered.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 December 2019
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. FCC Safety Radiotelephony Certificate was missing.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 10 December 2019
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Posted emergency instructions do not match the actions taken by the master and crew in the event of a man overboard incident.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wires were discovered in the vicinity of the ship's radar.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 10 December 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 December 2019
Resolved
A hatch in a cabin top must be weathertight. Hatch leading to the aft accommodation space is not weathertight due to a large crack in wooden frame.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019
Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel. Starboard aft battery box lid is not secure.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 December 2019
Resolved
The master shall ensure that one or more placards meeting the requirements of 33 CFR 151 are displayed in prominent locations. Garbage placard was missing.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 December 2018
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are suitable condition and fit for service intended. Water was entering the vessel from the rudder post when conducting steering tests underway. Steering system shall be removed and packing replaced.
46 CFR 176.814
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 December 2018
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high. Exterior side of hatch missing marking. Properly label Emergency Escape Hatch.
46 CFR 185.606
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 December 2018
Resolved
Remote fuel shut off stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve & direction of operation. Label was worn as it is under a section of carpet in a high traffic area.
46 CFR 185.608
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2018
Resolved
Cable or wiring servicing vital systems or emergency loads must be routed as far as practicable from high risk fire areas, such as galleys, laundries and machinery spaces. Wires from the vessels radar and VHF system were exposed and unsecure in the engine room. Properly secure wires.
46 CFR 183.340 (3) (e)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 December 2018
Resolved
Ring life buoys must be stowed in a way that it can be rapidly cast loose. Buoy was secured using Velcro. Install proper mounting hardware.
46 CFR 180.70 (b) (3)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 December 2018
Resolved
Cartons shall be of the standard commercial unit, properly labeled to designate the name, size of contents and method of use, and shall contain all information required by federal and state laws. Aspirin in the vessels first aid kit was expired. Replace aspirin.
46 CFR 160.041 (a)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 December 2018
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Sections of the port and starboard quarter of the vessel had gouges in the fiberglass. Repair area surrounding gouges on both port and starboard quarter.
46 CFR 177.100
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2017
Resolved
Repair starboard Aft stanchion crack at base weld. 46 CFR 177.900
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2017
Resolved
Tighten port aft stanchion base. 46 CFR 177.900
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 13 November 2017
Resolved
Provide adequate bond between fuel fill and fuel tank. 46 CFR 182.445(g)
Documentation › Certificates/Documents › FCC SSL
Issued 13 November 2017
Resolved
Provide evidence of valid FCC Radio Station Authorization. 46 CFR 80.13
Navigation › Piloting/Steering › Marine Charts
Issued 13 November 2017
Resolved
Replace or update navigation chart. 46 CFR 184.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 November 2017
Resolved
Replace or restock First Aid Kit. 46 CFR 184.710
Engineering › Steering Gear System › Bracket/Clamp
Issued 13 November 2017
Resolved
Replace rudder post clamp. 46 CFR 182.600
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 November 2017
Resolved
Replace all retro reflective tape on the life float. 46 CFR 180.200
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 November 2017
Resolved
Properly secure engine room vent covers. 46 CFR 177.600
Fire Fighting › Fire Bucket › Stenciling
Issued 13 November 2017
Resolved
Relabel Fire buckets. 46 CFR 181.610
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 November 2017
Resolved
Replace lifejacket donning instructions. 46 CFR 185.516
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 November 2017
Resolved
Replace flashlight at the operating station. 46 CFR 183.430
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 13 November 2017
Resolved
Submit a draft Preventative Maintenance Plan as per NVIC 2-16. 46 CFR 176.802
Engineering › Bilge Water Management System › Pump
Issued 3 December 2015
Resolved
Sub electric pump installed in engine room not UL listed, replace with a pump approve under UL1113.
Documentation › Markings/Placards › Warning Signs
Issued 10 January 2012
Resolved
Re-label emergency escape hatch.
Engineering › Pressure Vessel › Relief Valve
Issued 10 January 2012
Resolved
Install 100 PSI relief valve on water heater in E/R.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2012
Resolved
Post COI under glass in accomodation space.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 January 2012
Resolved
Provide the required amount of aspirin in first-aid kit.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 January 2012
Resolved
Provide life jacket donning placard for second type of life jacket onboard.
Documentation › Logs/Records › Drug Test Records
Issued 15 July 2009
Resolved
Company could not provide a copy of the latest MIS form as required by 46 CFR 16.50.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 12 December 2008
Resolved
Install flame shield to Racor fuel filter IAW 46 CFR 182.455 (b)(6).
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Company policy missing as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Security of records not maintained in accordance with 49 CFR 40.333.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Statistically based method not currently being used to determine when random testing takes place. (Employees currently get tested every May.)
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230. (Employees currently tested every May.)
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Arrangements not made for reasonable cause testing as required by 46 CFR part 16.250 and 33 CFR part 95.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company’s drug and alcohol policy in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 16 January 2007
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500. Note: Company has the option of submitting the MIS form for 3 yrs and then maintaining the three years of submissions as proof of compliance in accordance with 46 CFR 16.500 as long as the company employees 10 or fewer employees in a given year.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.