MAURY USCG vessel records
← All vessels

PRIVATEER

PRIVATEER is a 1976 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in November 2025, along with 56 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 18 November 2025.

Built
1976
Last inspected
18 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD5591
708442
Flag
UNITED STATES
Maury page id
psix-708442

Documentation record

Registered dimensions (L × B × D)41.0 ft × 13.0 ft × 5.0 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLANDER YACHT CORPORATION · IRVINE, CA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

18 November 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8260490
26 November 2024 Deficiency Check · Hull Examination · Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8040160
21 November 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8034459
26 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7870159
15 November 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7595461
14 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7593978
14 December 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367206
24 August 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7295689
16 November 2020 Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7096496
3 July 2020 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6999683
10 December 2019 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6871466
5 December 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6867976
19 December 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6598007
3 December 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6589315
13 November 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6308045
6 December 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6053339
15 November 2016 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6041033

Deficiency record · 56

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Engine room battery bank was found to have a loose terminal connection. 46 CFR 183.350(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operator sent MI picture of battery with tightened terminal connections.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 November 2025 Resolved
Each...survival craft...on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Life float was found to have numerous holes around the exterior body. 46 CFR 185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operation sent MI picture of the Life Float with patch kit applied to holes identified by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 November 2025 Resolved
Each buoyant apparatus must have Type II retroreflective material. Life float had insufficient retroreflective material. 46 CFR 160.010-4(p)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operator sent MI picture of the life float with fresh retroreflective tape applied where worn tape was identified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025 Resolved
At each...inspection for certification of a vesseL...be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings...and their attachment to the hull structure. The port aft-most stanchion was found to be up-rooted from the hull. 46 CFR 177.900(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operator sent MI a pictures of the new bolt and the new bolt installation for the stanchion.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2025 Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The water light battery in the life float was found to be expired. 46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operator sent MI picture of new water light battery.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. The water light battery in the life ring was found to be expired. 46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 23 December 2025
Resolution: Operator sent MI picture of new water light battery.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Radio station authorization did not have the appropriate radio service for vessel type. 46 CFR 184.502
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 5 February 2026
Resolution: Operator sent MI email with PDF copy of updated Radio Station Authorization.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI observed aft compartment drawer support right above the steering pulley to be loose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2024
Resolution: Aft support was sufficiently installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 November 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed water leak in the overhead of the engine room compartment directly above the engine where the binnacle is mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 14 January 2025
Resolution: Conducted def check and found vessel added a cover that prevents water from penetrating the binnical. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. MI observed the fire extinguisher at the operating station was a 5BC. Replace 5BC extinguisher with a 10BC to meet the requirements stated on COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2024
Resolution: Fire extinguisher was sufficiently replaced to MI satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 November 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall...have the vessel read for inspections of the hull structure and its appurtenances, including: on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel's mizzen boom topping lift tang was observed shearing into the shackle, procure new parts and repair to MI satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2024
Resolved 14 January 2025
Resolution: MI observed the shackle in good condtion, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 November 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve… MI found the retro tape on the life float to be wasted. Replace retro to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2024
Resolution: Life rafts had new SOLAS tape installed to MI satisfaction.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 November 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2025
Resolution: Owner submitted currently validated station license, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Discovered one life jacket damaged from electrical burns. Vessel to replace damaged life jacket. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2022
Resolution: Vessel replaced damaged life jacket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel to install or replace guards on electrical equipment, to the satisfaction of the Coast Guard Marine Inspector, in the following locations: terminal board in STBD storage compartment, electrical box in PORT storage compartment, below deck in main cabin. 46 CFR 183.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2022
Resolution: Vessel installed guards on electrical equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 November 2022 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Vessel to repair or replace faulty main bilge pump to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2022
Resolution: Vessel replaced faulty bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel to repair or replace faulty shaft packing gland to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2022
Resolution: Vessel repaired faulty shaft packing gland.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 December 2021 Resolved
On a nonmetallic vessel, the enclosures and frames of electric equipment must be bonded together to a common ground by a normally non-current carrying conductor. Grounding wire on battery terminal needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 4 January 2022
Resolution: Grounding wire was properly replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Wing nuts were present on the battery terminal connections.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 4 January 2022
Resolution: Wing nuts were replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 December 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 4 January 2022
Resolution: Aspirin in first aid kit was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 August 2021 Resolved
Rail courses or the equivalent must be installed between a top rail and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except: on the passenger deck of a vessel on an excursion trip the following must be installed: bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches) Vessel's course height is equivalent to 12 inches
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 26 February 2024
Resolution: Vessel installed netting between courses.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2020 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Lanyard is significantly longer than 6 feet.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2020
Resolution: Lifering lanyard was adjusted on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2020 Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. The items contained in first-aid kit shall be listed in Table 160.041-4(b). Eye dressing packets are expired and must be replaced.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2020
Resolution: Operator bought new eye patch kits from the store and replaced the expired equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring life buoy grab line is severely deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Float-free link is missing the identification tag.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life float lines and painter are deteriorated and not stowed to be able to run freely.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 December 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Water light line is severely deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 December 2019 Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. Loose fire proof lagging on engine exhaust piping was discovered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 December 2019 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Loose insulation in the starboard overhead of engine room space was discovered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 December 2019 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. FCC Safety Radiotelephony Certificate was missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 10 December 2019 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Posted emergency instructions do not match the actions taken by the master and crew in the event of a man overboard incident.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 28 January 2020
Resolution: Received photo from operator clearing the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wires were discovered in the vicinity of the ship's radar.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 3 February 2020
Resolution: Operator sent photo of cleared deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 10 December 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 5 February 2020
Resolution: Received photo of valid medical certificate for [name withheld].
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 December 2019 Resolved
A hatch in a cabin top must be weathertight. Hatch leading to the aft accommodation space is not weathertight due to a large crack in wooden frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 3 February 2020
Resolution: Operator sent photo of cleared deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019 Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel. Starboard aft battery box lid is not secure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 6 February 2020
Resolution: Received photo from operator of secured battery box lid.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 December 2019 Resolved
The master shall ensure that one or more placards meeting the requirements of 33 CFR 151 are displayed in prominent locations. Garbage placard was missing.
Action required: 10 - Deficiency Rectified
Due 10 January 2020
Resolved 10 December 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 December 2018 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are suitable condition and fit for service intended. Water was entering the vessel from the rudder post when conducting steering tests underway. Steering system shall be removed and packing replaced. 46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2019
Resolved 6 February 2019
Resolution: Repairs were conducted and sea trial passed. New packing and bearins installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 December 2018 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high. Exterior side of hatch missing marking. Properly label Emergency Escape Hatch. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 February 2019
Resolution: Emergency exit signage was clearly marked on the deck of the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 December 2018 Resolved
Remote fuel shut off stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve & direction of operation. Label was worn as it is under a section of carpet in a high traffic area. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 February 2019
Resolution: Fuel shut off markings re done, clearly visible
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2018 Resolved
Cable or wiring servicing vital systems or emergency loads must be routed as far as practicable from high risk fire areas, such as galleys, laundries and machinery spaces. Wires from the vessels radar and VHF system were exposed and unsecure in the engine room. Properly secure wires. 46 CFR 183.340 (3) (e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 February 2019
Resolution: Exposed wires were correctly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 December 2018 Resolved
Ring life buoys must be stowed in a way that it can be rapidly cast loose. Buoy was secured using Velcro. Install proper mounting hardware. 46 CFR 180.70 (b) (3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 February 2019
Resolution: Proper mounting hardware installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 December 2018 Resolved
Cartons shall be of the standard commercial unit, properly labeled to designate the name, size of contents and method of use, and shall contain all information required by federal and state laws. Aspirin in the vessels first aid kit was expired. Replace aspirin. 46 CFR 160.041 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 February 2019
Resolution: New bottle of Asprin
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 December 2018 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Sections of the port and starboard quarter of the vessel had gouges in the fiberglass. Repair area surrounding gouges on both port and starboard quarter. 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 January 2019
Resolved 4 December 2018
Resolution: Repairs were conducted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2017 Resolved
Repair starboard Aft stanchion crack at base weld. 46 CFR 177.900
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: Stanchion was removed welded and placed back on
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2017 Resolved
Tighten port aft stanchion base. 46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: stanchion was tightened
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 13 November 2017 Resolved
Provide adequate bond between fuel fill and fuel tank. 46 CFR 182.445(g)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: Bond between fuel fill and tank - wire goes from the tank to the terminal then a second wire goes from the terminal to the fuel fill.
Documentation › Certificates/Documents › FCC SSL
Issued 13 November 2017 Resolved
Provide evidence of valid FCC Radio Station Authorization. 46 CFR 80.13
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: of FCC radio authorization with a 2027 expiration date
Navigation › Piloting/Steering › Marine Charts
Issued 13 November 2017 Resolved
Replace or update navigation chart. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: new chart with a 2017 print date.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 November 2017 Resolved
Replace or restock First Aid Kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: new first aid kit
Engineering › Steering Gear System › Bracket/Clamp
Issued 13 November 2017 Resolved
Replace rudder post clamp. 46 CFR 182.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: all old hose clamp on rudder post were removed and replaced with two new ones instead of one.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 November 2017 Resolved
Replace all retro reflective tape on the life float. 46 CFR 180.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: old reflective tape on life raft removed and replaced with new.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 November 2017 Resolved
Properly secure engine room vent covers. 46 CFR 177.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: both engine room vent covers replaced with new
Fire Fighting › Fire Bucket › Stenciling
Issued 13 November 2017 Resolved
Relabel Fire buckets. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 November 2017 Resolved
Replace lifejacket donning instructions. 46 CFR 185.516
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: life jacket donning instructions reprinted, laminated, and reposted
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 November 2017 Resolved
Replace flashlight at the operating station. 46 CFR 183.430
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 13 November 2017 Resolved
Submit a draft Preventative Maintenance Plan as per NVIC 2-16. 46 CFR 176.802
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 15 December 2017
Resolution: draft for preventative maintenace plan submitted

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.