TOPEKA

TOPEKA is a 2000 freight ship. The Coast Guard has recorded 1 inspection in 2016, along with 6 deficiencies.

Records in 2016. Most recent: inspection, 14 March 2016.

Built
2000
Last inspected
14 March 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 March 2016
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9211585
Flag
MALTA
Maury page id
psix-7087

Documentation record

Tonnage as PSIX records it40562 - Convention (Subpart B), Gross Ton
26139 - Convention (Subpart B), Net Ton
87337 - Displacement, Ton
74710 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

14 March 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5832597

Deficiency record · 6

Deck/Cargo › Holds/Tanks › Bulkhead
Issued 14 March 2016 Resolved
1160; The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure that the ship is in all aspects will remain fit to proceed to sea without danger to the ship or persons onboard. The vessel has a 40cm crack in void #3 that has been leaking ballast water into void. Vessel failed to report condition to the COTP prior to entering.74SOLAS(97) I/11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 March 2016
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 March 2016 Resolved
0750; The regulations in this chapter and are embodied as appropriate having regard to the type of ship and the potential fire hazard involved. F/O Settling tank overflow pipe is leaking. #1 main L/O pump is leaking and associated piping support brackets are cracked. Line shaft bearing is also leaking oil. Continued on narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 March 2016
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 14 March 2016 Resolved
2035; In pipe duct spaces # 209, 210, and 216 wires runs between decks with wire through blocks. The spaces are being used for storage and improper/undocumented welding around light fixtures. The fire integrity of bulkheads and decks shall be maintained. 74SOLAS(97) II-2/43 & 44
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 March 2016
Personnel › Training › Familiarization Training
Issued 14 March 2016 Resolved
0695; The training manual shall contain vessel specific information regarding life saving appliances provided on the ship and on the best method of survival. Vessel's training manual is not ship specific. 74SOLAS(14) III/35.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016
Lifesaving › Lifeboat › Safety Belt
Issued 14 March 2016 Resolved
0610; All life saving appliances shall be in working order and ready for immediate use. The lifeboat seat belt buckles were found wasted/rusted and unable to properly secure. Additionally, shipping bands were still on liferafts, and fwd liferaft ladder had shackles missing. 74SOLAS(14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 14 March 2016 Resolved
0599; To prevent the ignition of flammable liquids, proper means shall be provided to control leaks of flammable liquids. Approximately 2.5 cm of oil found throughout Boatswain store due to hydraulic leak, primarily in fwd Bosun workshop. Issue identified and corrected by crew. Additionally, fire doors throughout vessel needs adjustment and have been acknowledged by crew. 74SOLAS(97) II-2/2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016