Records in 2016. Most recent: inspection, 14 March 2016.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 14 March 2016
Resolved
1160; The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure that the ship is in all aspects will remain fit to proceed to sea without danger to the ship or persons onboard. The vessel has a 40cm crack in void #3 that has been leaking ballast water into void. Vessel failed to report condition to the COTP prior to entering.74SOLAS(97) I/11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 March 2016
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 March 2016
Resolved
0750; The regulations in this chapter and are embodied as appropriate having regard to the type of ship and the potential fire hazard involved. F/O Settling tank overflow pipe is leaking. #1 main L/O pump is leaking and associated piping support brackets are cracked. Line shaft bearing is also leaking oil. Continued on narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 March 2016
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 14 March 2016
Resolved
2035; In pipe duct spaces # 209, 210, and 216 wires runs between decks with wire through blocks. The spaces are being used for storage and improper/undocumented welding around light fixtures. The fire integrity of bulkheads and decks shall be maintained. 74SOLAS(97) II-2/43 & 44
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 March 2016
Personnel › Training › Familiarization Training
Issued 14 March 2016
Resolved
0695; The training manual shall contain vessel specific information regarding life saving appliances provided on the ship and on the best method of survival. Vessel's training manual is not ship specific. 74SOLAS(14) III/35.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016
Lifesaving › Lifeboat › Safety Belt
Issued 14 March 2016
Resolved
0610; All life saving appliances shall be in working order and ready for immediate use. The lifeboat seat belt buckles were found wasted/rusted and unable to properly secure. Additionally, shipping bands were still on liferafts, and fwd liferaft ladder had shackles missing. 74SOLAS(14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 14 March 2016
Resolved
0599; To prevent the ignition of flammable liquids, proper means shall be provided to control leaks of flammable liquids. Approximately 2.5 cm of oil found throughout Boatswain store due to hydraulic leak, primarily in fwd Bosun workshop. Issue identified and corrected by crew. Additionally, fire doors throughout vessel needs adjustment and have been acknowledged by crew. 74SOLAS(97) II-2/2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2016