This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it16418 - Convention (Subpart B), Gross Ton 16418 - Simplified, Gross Ton 9409 - Convention (Subpart B), Net Ton 27172 - Dead Weight, Metric Ton 33272 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
17 September 2020Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7059999
8 September 2020PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7048339
3 September 2020Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7049330
19 November 2017Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6309465
17 October 2017ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6280467
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 8 September 2020Resolved
The firemans outfit or sets of personal equiptment shall be so stored as to be easily accessible and ready to use. PSCO observed SCBA low pressue alarm not working.
74SOLAS(97)
II-2/17.4
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2020
Resolved 19 September 2020
Resolution: PSC NOLA recieved report from [name withheld] attesting to the service report retifying the deficieny satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 October 2017Resolved
0750-Fire Prevention - PSCO observed: A. doors in the vertical stariwell being held back by installed clips. B. 2 holes in the door leading into Engine casing from changing room. C. self closing mechanism leading to elecrical cable runk was disconnected. D. doors in purifier room held in the open position.
SOLAS 74 am II-2/47
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 19 November 2017
Resolution: PSC NOLA received a class report from Russian Maritime Register of Shipping satisfying the requirement.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 October 2017Resolved
0715 - Alarms -PSCO observed the smoke detector in the purifier room was covered with a plastic bag.
- SOLAS 74 am II_2/13
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 19 November 2017
Resolution: PSC NOLA received a class report from Russian Maritime Register of Shipping satisfying the requirement.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 17 October 2017Resolved
0899 - Accident Prevention - Vessel could not provide transfer procedures IAW with 33 CFR.
-33 CFR 155.720
Action required: 703 - Prior to bunkering operations
Due 18 October 2017
Resolved 3 September 2020
Resolution: VESSEL EMAILED TRANSFER PROCEDURES AND CLASS REPORT.