Records from 2011 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 15
26 June 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8416307
24 February 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8083853
10 January 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8060764
12 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033348
27 November 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7829713
2 May 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679431
10 November 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592781
2 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7579103
16 September 2021
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7307314
26 October 2020
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7077210
17 October 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6812846
14 December 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6597953
13 November 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6579878
8 November 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6303479
29 November 2016
Hull Examination · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6049387
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2026
Resolved
A visual indicator must be provided at the operating station to indicate when an automatic bilge pump is operating. Repair or replace visual indicator for the Void #3 automatic bilge pump at the control station to restore proper functionality.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2026
Resolved 1 July 2026
Resolution: Rectified. Visual indicator is fully operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2025
Resolved
(a) A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions.
MI observed Fireboy in override condition.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 February 2025
Resolved
Each vessel that operates on the high seas, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
§ 180.68 Distress flares and smoke signals.
Hydrostatic release was expired.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 February 2025
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers:
On each life float and buoyant apparatus. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus.
Lifefloat was missing vessel name and number of persons capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date."
Vessel did not undergo annual inspection. Vessel must satisfactorily undergo Coast Guard inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: completed coi renewal
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 November 2023
Resolved
A vessel certificated to operate on a rivers route within one mile of land is not required to carry survival craft.
Vessels life floats are unserviceable due to interior foam being exposed. Vessel is restricted to not more than 1 mile from shore.
46 CFR 180.200(c)
46 CFR 180.208(c)
Action required: 705 - Other - as specified
Resolved 14 November 2024
Resolution: New life floats placed on board the vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 November 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a).
Vessels port void #3 bilge pump was inoperable.
46 CFR 182.520(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: Tested bilge pump during coi renewal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 November 2023
Resolved
A hatch exposed to the weather must be watertight.
Aft hatch leading to steering system was not watertight.
46 CFR 179.360(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 November 2024
Resolution: Hatch gasket replaced
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 10 November 2022
Resolved
During the internal exam of the starboard fuel tank space the forward transverse bulhead (aft engine room transverse) has a crack requiring repair. FRP to be repaired to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 8 May 2023
Resolution: Crack was satisfactorily repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2022
Resolved
All fiber reinforced plastic (FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type in accommodation spaces, service spaces, and isolated spaces that contain an ignition source.
Smoke detector in accommodation/galley space is expired and has no batteries.
46CFR177.410
46CFR76.27-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2022
Resolved 10 November 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 November 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in spaces.
Bilge high level alarms are only audible. The alarm in the engine room is inop.
46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2022
Resolved 29 December 2022
Resolution: Installed new alarms with visual.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 November 2022
Resolved
Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable.
EPIRB is not being tested monthly.
46CFR185.728
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 10 November 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 November 2022
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct monthly inspections of portable extinguishers. Monthly inspection of portable fire extinguishers hasn't been conducted since the annual servicing.
46CFR176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 10 November 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 November 2022
Resolved
A vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List.
The U.S. Coast Pilot and Coast Guard Light List onborad are not up-to-date.
46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 10 November 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2022
Resolved
Employers must maintain records of chemical tests and must make these records available to Coast Guard officials upon request. Records onboard are expired.
46CFR185.212
46CFR16.260
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 10 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 November 2022
Resolved
Each hatch in a cabin top must have securing-devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss.
Hatches are not secured.
46CFR179.360
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2022
Resolved 29 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2022
Resolved
Ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Ring bouy didn't have the name of the vessel marked.
46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 November 2022
Resolved 2 November 2022
Resolution: Ring Bouy is properly marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 November 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 22 November 2022
Resolution: Captain of vessel was fired last week so this is now clear. Vessel is a seasonal operator and will start operations in the spring with new Captain and crew.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 September 2021
Resolved
Ventilation required to shut down upon operation of installed system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 27 September 2021
Resolution: Operator sent video of proper shut down operation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 December 2018
Resolved
PS Navigation light needs to be replaced. Inspector found light not working and then vessel operator tapped the light to make it work. Inspector then tapped the light and it stopped working. Operator agreeded for light to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 21 December 2018
Resolution: Both Nav lights have been replaced with LED lights.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 November 2016
Resolved
Provide updated DAPI enrollment paperwork.
Due 29 December 2016
Resolved 13 December 2016
Resolution: DAPI enrollment certificate provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 November 2016
Resolved
Conduct annual servicing of engine room Fireboy and portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Fireboy serviced.
Communications › Radio Communications › EPIRB
Issued 29 November 2016
Resolved
Renew EPIRB battery and hydrostatic release. Item to be corrected prior to operating 3 NM from the baseline.
Action required: 705 - Other - as specified
Resolved 13 December 2016
Resolution: EPIRB battery and hydrostatic release renewed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 November 2016
Resolved
Repair hydraulic leak in steering system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Hydraulic ram and hoses replaced.