← All vessels
AIR TIME
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG East District (CGD-E) · Other hulls named AIR TIME
AIR TIME is a 2004 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2004, most recently in August 2020, along with 17 deficiencies and 2 casualty investigations between 2005 and 2011.
Records from 2004 to 2020. Most recent: inspection, 31 August 2020.
- Built
- 2004
- Last inspected
- 31 August 2020
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2005–2011
Identity
1160978
WDG3877
709068
Flag
UNITED STATES
367530610
Maury page id
psix-709068
Inspections, by type
…with no type recorded4
Years with a record
16 calendar years (2004–2020)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS, INC · CLERMONT, NJ, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVIRGINIA BEACH, VA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 9 August 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN7940MMSI 367530610 · active · compulsorily equipped · granted 10 May 2023, expires 10 May 2033
WDG3877MMSI 367530610 · expired · compulsorily equipped · granted 16 May 2012, cancelled 16 July 2022
WDC5901MMSI 367048210 · expired · compulsorily equipped · granted 8 June 2005, cancelled 8 August 2015
WDB9310MMSI 366973530 · expired · compulsorily equipped · granted 24 August 2004, cancelled 25 October 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 31
31 August 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7044975
22 August 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6789305
26 June 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6677689
31 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6429854
26 May 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6159885
22 May 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6147318
26 October 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6029047
27 June 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5916587
28 September 2015
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5730636
19 August 2014
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4954409
28 June 2012
Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4360186
13 June 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4343562
23 May 2012
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4311526
8 December 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4204539
2 December 2010
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3902608
23 July 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3533265
21 October 2008
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3345833
1 August 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3285172
16 June 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3234802
6 July 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2985485
26 June 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2974648
26 June 2007
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2974769
7 June 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2968973
26 October 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2808674
18 September 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2781010
13 September 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2777546
29 September 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2503957
24 May 2005
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2366987
5 April 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2326754
27 October 2004
Initial Certification · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2229049
28 July 2004
Construction Oversight · Simplified Stability Test · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2228881
Deficiency record · 17
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 August 2020
Resolved
Found when testing the engine shutdown and override controls; found system shut down the engines, but did not give a visual or audible alarm at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 August 2019
Resolved
Found ventilation dampers for engine room missing. Provide adequate vent closures to satisfaction of OCMI.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 May 2017
Resolved
EPIRB hydrostatic release is expired. Replace EPIRB hydrostatic release prior to carrying passengers.
Engineering › Fuel Oil Service System › Hose
Issued 22 May 2017
Resolved
Fuel line fittings are corroded. Replace fuel line fittings.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 22 May 2017
Resolved
Penetration through bulkhead in machinery space is not sealed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2017
Resolved
Lifeline on life buoy is worn. Replace lifeline.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 September 2015
Resolved
Certificate of Documentation is expired. Vessel shall renew Certificate of Documentation prior to carrying passengers.
Documentation › Certificates/Documents › FCC SSL
Issued 19 August 2014
Resolved
Operator did not have a copy of his Radio Operator's Permit. Operator is restricted to operation 1,000 feet from shore.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 August 2014
Resolved
Vessel's emergency instructions not tailored to specific ship's operations (parasailing). Provide proof of sufficient emergency procedures to the satisfaction of marine inspector.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 May 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Stability › Weathertight Integrity › General
Issued 16 June 2008
Resolved
Remove and replace latch on engine compartment weathertight hatch.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 June 2008
Resolved
Replace DAPI two hour alcohol test kits.
Communications › Radio Communications › EPIRB
Issued 26 June 2007
Resolved
Replace expired disposable hydrostatic release with a new unit prior to carrying passengers..
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 27 October 2004
Resolved
PROVIDE PROOF THAT 50% OF CREW IS CURRENT IN CPR/FIRST AID.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 October 2004
Resolved
ATTACH FLOATING WATERLIGHT TO LIFERING WITH 6' FLOATABLE LINE AND CORROSION RESISTANT DETACHABLE LINK PRIOR TO CARRIGE OF PASSENGERS.
Engineering › Bilge Water Management System › Hose
Issued 27 October 2004
Resolved
PROVIDE SUCTION LINE FOR PORTABLE BILGE PUMP SUITABLE TO REACH BOTTOM OF ALL COMPARTMENTS.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 October 2004
Resolved
UPDATE EMERGENCY INSTRUCTIONS UNIQUE TO VESSEL EMERGENCY SITUATIONS.
Casualty record · 2
29 September 2005Routine · role: Involved in a Marine Casualty · activity 2503957
20 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4052678
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.