MAURY USCG vessel records Sign in
← All vessels

PAMIR

PAMIR is a 2004 tank ship. The Coast Guard has recorded 34 inspections since 2004, most recently in March 2020, along with 9 deficiencies and 9 operational controls.

Records from 2004 to 2020. Most recent: inspection, 14 March 2020.

Built
2004
Last inspected
14 March 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9276028 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
709230
Flag
MALTA
—
Maury page id
psix-709230

Inspections, by type

…with no type recorded17
Years with a record 12 calendar years (2004–2020)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it26240 - Simplified, Gross Ton
20992 - Simplified, Net Ton
29327 - Convention (Subpart B), Gross Ton
46654 - Dead Weight, Metric Ton
56278 - Displacement, Metric Ton
11980 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

14 March 2020 Ballast Water Examination · COC-CHEM & TVE Renew · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6918556
10 March 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6923640
18 June 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6437026
17 February 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6090520
8 December 2016 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6054378
26 September 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6007406
14 July 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4080806
24 December 2010 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3915870
10 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3691645
10 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3694419
8 December 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3646912
30 July 2009 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3551002
27 July 2009 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3542644
23 July 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3543331
22 September 2008 MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · COC-CHEM Renew · MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3330276
6 November 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3093957
6 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3093968
10 September 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3053275
8 September 2007 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3052502
7 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2870818
4 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2866895
15 September 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2778847
16 August 2006 Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2749498
25 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2521807
23 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2499587
29 August 2005 Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478230
26 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2440599
1 June 2005 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2374760
8 May 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2352354
5 May 2005 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2349867
8 March 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2306859
10 August 2004 ISPS II Exam · COC-TVE Annual
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2162432
10 August 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2162684
6 August 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2158281

Deficiency record · 9

Operations/Management › Drills/Instruction › Not Conducted
Issued 26 September 2016 Resolved
0371: Enclosed space entry and rescue drills should be planned and conducted in a safe manner. Vessel does not have an adequate stretcher for recovering persons from void spaces. Recommend ship be provided wit [name withheld] stretcher as per W.H.O., 74 SOLAS (14) III/19.3.6.1, WHO 2ed Ch.1, pg 48, 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2016
Resolution: A new stretcher was purchased and placed on board.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 September 2016 Resolved
1850: Tanker , including oil tanker as defined in SOLAS, should be provided with means to enable the crew to gain access to the bow even in severe weather conditions. The access shall be by means of either a walkway or the deck or permanently constructed gangway of substantial strength above the level of the superstructure deck on the first tier of the deck house and should be, See Narrative.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 December 2016
Resolution: Addressed and correctecd by Class.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 26 September 2016 Resolved
2510: Vessel must maintain Ballast Water Management Plan that has been specifically for the vessel that will allow those responsible to understand and follow it. Crew is not using the correct Ballast Water Handling log forms. In addition, the crew is not filling out the forms for the Bio-Fouling management plan. Training has not been carried out and the ballast water strainer have, See Narrative.
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 26 September 2016
Resolution: Discussed plans with the Captain, Chief Mate and Chief Engineer.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 November 2007 Resolved
06NOV2007: Vessel reported X-Band Radar inoperable. Vessel must provide a technicians report attesting to the proper operation of X-Band Radar prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2007
Resolution: PSCO received technican report. Radar/ Arpa now working properly and ready for normal operations.
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 10 September 2007 Resolved
Emergency generator autostart function inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2007
Resolution: DNV report
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 September 2007 Resolved
Emergency Diesel Generator automatic start could not be demonstrated.. Manual start was demonstrated satisfactory, vessel is prohibited from departing port of Jacksonville until automatic start of the emergency diesel generator is demonstrated to the satisfaction of the attending classification society
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2007
Resolution: Vessel allowed to depart Port of Jacksonville to make repairs in Miami. Contacted Sector Miami and informed them of the situation.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 8 September 2007 Resolved
Vessel overflow alarm light does not work when overflow is indicated. Demonstrate proper operation of indicating light PRIOR TO LOADING CARGO. To the satisfaction of attending U.S. Coast Guard Inspector or Class.
Action required: 705 - Other - as specified
Resolved 6 November 2007
Resolution: PSC Office Sector Houston/Galveston received a Class report attesting to the proper operation of the vessels overflow lamp.
Deck/Cargo › Ballast › Vents
Issued 8 September 2007 Resolved
Ballast tank vent screens are covered with paint. Remove paint or replace flame screens as required.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 6 November 2007
Resolution: PSC Office Sector Houston/Galveston received Class report attesting to the proper order of ballast tank vent screens.
Documentation › Certificates/Documents › TVE Letter (CG-840S-1)
Issued 16 August 2006 Resolved
Vessel commenced cargo ops (discharging) with expired USCG COC. Vessel did not request cargo ops permission with USCG.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2007
Resolution: After vessel completed COC exam, cleared def.

Ownership record