Records from 2010 to 2026. Most recent: inspection, 25 June 2026.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2026
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. MI observed dead end wiring from previously installed water heater. Remove dead end wiring to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2026
Resolved 13 July 2026
Resolution: Operator provided imagery to MI showing unused wiring is secured and isolated from power source.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 October 2025
Resolved
Except as allowed by paragraph (d) of this section, each vessel constructed of a material other than wood certificated to operate on a limited coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Marine inspector (MI) observed the 12-person life float was deteriorated making it not fit for service. Vessel is restricted to a maximum of 22 persons on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 29 December 2025
Resolution: New 12 man life raft was installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 October 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI found hydrostatic release unit for EPIRB was expired. Vessel is restricted to operating within 3 NM from the coastline until hydrostatic release unit for EPIRB is replaced.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 23 October 2025
Resolution: Vessel replaced the hydrostatic release with a new one and sent a picture for proof.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 October 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found masthead light and both port and starboard navigation lights non-operational. Vessel is restricted to daytime operations until all navigation lights are repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 14 October 2025
Resolution: Vessel submitted pictures of the masthead light and both port and starboard nav lights working.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 October 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. MI observed the COD on board is expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 9 January 2026
Resolution: O/O provided copy of certificate of documentation for the vessel issued 14FEB25.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 October 2025
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. MI observed the vessel did not have a current MIS report from their drug testing consortium.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 14 October 2025
Resolution: Vessel's master submitted a current MIS report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2025
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. MI observed there was no firefighting servicing certificate on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 8 October 2025
Resolution: The vessel submitted a satisfactory report of their last fire fighting equipment service.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 August 2024
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A light to indicate discharge. Indicator light for system status "Charged" was not illuminated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2024
Resolved 26 August 2024
Resolution: New sea fire indicator provided and operational
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector; Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Pre-engineered fixed gas fire extinguishing system for engine room was inoperable. System display status indicator was found without power and when system was tested was unable to secure engine or make notification to operator if system was deployed. 46 CFR 181.420(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2024
Resolution: Operator demonstrated proper operation of SEAFIRE system to MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. Visual indicator was found inoperable for the house space bilge. 46 CFR 182.530(a) Action code: 705: rectify within 7 days.
Action required: 705 - Other - as specified
Due 22 August 2024
Resolved 2 September 2024
Resolution: New indicator provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided the pump is permanently mounted to bilge. Submersible bilge pump in house bilge space was found detached from hull. 46CFR182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 16 September 2024
Resolution: Bilge pump secured to hull with 4200
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2024
Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump provided the hose or tube does not penetrate any required watertight bulkheads and is of good quality and of substantial construction, suitable for the intended use; and highly resistant to salt water, petroleum oil, heat, and vibration. Flexible bilge hose for submersible pump in engine room was found wasted. 46 CFR 182.520 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 18 September 2024
Resolution: Hose replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. House batteries in house bilge space were found with exposed battery terminals.46 CFR 183.354(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 23 October 2024
Resolution: Covers provided and secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Multiple connections were found on house batteries located in house bilge space without any overcurrent protection and without approval or oversight from Coast Guard. All power supply for electrical conductors shall be from the vessel’s distribution panel with properly sized overcurrent protection per the vessels approved electrical plans. If installed distribution panel is unable to support accessiories installed onboard, submit plans to add an additional electrical distribution panel. 46CFR183.380(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 23 October 2024
Resolution: DIstro panel provided with proper overcurrent protection for all ungrounded circiuts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
If individual wires, rather than cable, are used in systems greater than 50 volts, the wire must be in conduit. Electrical pigtail from inverter in house bugle space was found installed in a manner that exposes crew to an electrical shock hazard. Electrical wires shall be in conduct and an electrical receptacle box with cover; or properly terminate wires and discontinue use. 46CFR183.340(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 26 August 2024
Resolution: wire properly terminated
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; and be be No. 14 American Wire Gauge (AWG) or larger. Conductors in control and indicator circuits must be No. 22 AWG or larger. Multiple conductors in house bilge space were found to be not designed for marine use and of an inadequate size (AWG). 46CFR183.340(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 23 October 2024
Resolution: Conductors replaced with 14AWG or larger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Closure devices shall be a material that is not combustible and can be mounted near the supply ducts without being destroyed from the marine environment. 46CFR182.465(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 18 September 2024
Resolution: Aluminum covers provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy was missing retroreflective material; 4 strips on each side and evenly spaced apart. 46CFR185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 16 September 2024
Resolution: retro tape applied
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 August 2024
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry: Six hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, and Six hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or 12 red flare distress signals total. Vessel was found with 11 red flare distress signals; crew sent to purchase additional flare. 46CFR180.68(a)
Action required: 10 - Deficiency Rectified
Due 15 August 2024
Resolved 15 August 2024
Resolution: Vessel crew purchased and placed on board additional flare to meet the requirements for their designated route.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 August 2024
Resolved
For each marine casualty required to be reported by § 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. Expired alcohol testing equipment was found expired, minimum of 02 tests are required on board. 46CFR185.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 2 September 2024
Resolution: Testing strips provided
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2024
Resolved
A power-driven vessel underway shall exhibit: A masthead light forward; Masthead light means a white light placed over the fore and aft centerline of the vessel showing an unbroken light over an arc of the horizon of 225 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on either side of the vessel. Vessels masthead light was found extinguished, vessel restricted from operating during periods of restricted visibility. 33 CFR 83.23
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 26 August 2024
Resolution: New light installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: annual maintenance and recharging of extinguishers. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Inspection tags on all fire protection equipment noted the last servicing was performed in April 2022.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2023
Resolution: Vessel operator provided documentation of firefighting equipment servicing by South Coast Fire Protection, Inc. on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. The high level alarm for the main space does not provide a visual notification and the engine space provides a visual notification for the wrong location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 3 October 2023
Resolution: Witnessed satisfactory operational test of the vessel's three bilge high level alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2023
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter, approved in accordance with §160.050 in Subchapter Q of this chapter. The grab line was found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 3 October 2023
Resolution: The vessel was fitted with a new 24 inch ring buoy.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 September 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The battery of the vessel's EPIRB expired in February 2022 and the NOAA registration expired in January 2021. The vessel may not transit more than three miles from the coastline with passengers until these requirements are met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 October 2023
Resolution: The operator provided proof of a valid EPIRB installed on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2023
Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The vessel had only two fire buckets of the required size on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 12 September 2023
Resolution: A third fire bucket was provided for the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2023
Resolved
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] that affect the safety of the vessel include damage repair or replacement of electrical wiring and power supply systems. An extension cord was found connecting chargers in the lazarette to the anchor winch controls at the operating station. Submit electrical plans to the OCMI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 11 October 2023
Resolution: Operator provided pictures and a description of new wire installation.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 September 2023
Resolved
Except on a vessel limited to daytime operations, the magnetic compass must be illuminated. Magnetic compass illumination could not be proved.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 3 October 2023
Resolution: The vessel operator proved illumination of the magnetic compass.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 September 2023
Resolved
Abandon ship, man overboard, and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and a general description of the drill scenario and training topics. The vessel operator could not provide a log or documentation of drills and/or training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 3 October 2023
Resolution: Previous drill logs were provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 September 2023
Resolved
A vessel must carry adequate and up-to-date U. S. Coast Pilot or similar publication and Coast Guard Light List. The publications found on board were the 1995 editions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 12 September 2023
Resolution: Vessel operator provided proof of up-to-date publications on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 September 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection in accordance with §80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The certificate was found to be faded and illegible.
CITE: 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 2 November 2023
Resolution: A new FCC Radiotelephony Certificate is now posted on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 September 2023
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part (46 Part 16). The most recent MIS Report could not be produced.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 3 October 2023
Resolution: The most recent MIS Report was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
A visual indicator must be provided at the operating station. Vessel did not have labels on their bilge alarm lights at the operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 16 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Connections must be made to battery terminals with permanent type connections. Temporary type clamps are prohibited. Vessel had onboard wingnuts for their batteries in the fwd (house)compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 16 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 September 2022
Resolved
The float free link must be secured to the painter at one end and the vessel on the other end. Vessel painter was improperly attended to lifefloat grabline.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 September 2022
Resolved
A vessel on an limited coastwise route must carry: six red hand flares and six hand orange smoke distress signals. Vessel did not have the correct number of flares onboard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 September 2022
Resolved 26 September 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 March 2020
Resolved
Due to COVID-19 circumstances beyond the control of the vessel, the vessel is unable to meet the timeframe required by 46 CFR 176.107. Vessel is allowed 90 days to continue operations in accordance with the COI, and is required to make itself available for inspection prior to 27JUN2020. Issued CG-835v code 705c to extend COI Inspection 90 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2020
Resolved 23 June 2020
Resolution: Conducted satisfactory COI.
Fire Fighting › Ventilation Systems › Ducts
Issued 25 March 2016
Resolved
Provide means to completely close engine room ventilation, as space is protected by a fixed gas extinguishing system. Must be fixed prior to carrying passengers, IAW 46CFR182.465(h).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2016
Resolution: Vessel crew removed existing fabric/velcrow closure device, & installed hinged wood sheet with rubber gasket, properly sealing both port/stbd engine room vents - all satisfactory.