MAURY USCG vessel records Sign in
← All vessels

CQ PRINCESS

CQ PRINCESS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2003, most recently in September 2025, along with 29 deficiencies and 1 casualty investigation in 2011.

Records from 2003 to 2025. Most recent: inspection, 30 September 2025.

Built
2004
Last inspected
30 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI6746
710990
Flag
UNITED STATES
367721790 (licence lapsed)
Maury page id
psix-710990

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (2003–2025)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID CITY STEEL FABRICATING INC · LA CROSSE, WI, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOUISVILLE, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it178 - Convention (Subpart B), Gross Ton
73 - Regulatory (Subpart C or D), Gross Ton
63 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI6746MMSI 367721790 · expired · compulsorily equipped · granted 18 March 2016, cancelled 23 May 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 24

30 September 2025 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8236557
6 September 2024 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7961314
11 July 2023 COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7721445
26 April 2023 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7676174
25 October 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7566209
20 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7336406
13 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7059155
3 September 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6802741
18 July 2018 COI Inspection · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6483491
30 April 2018 Administrative Inspection · Drydock Extension
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6474223
29 November 2017 DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6315406
3 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6280929
13 September 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5999136
1 September 2015 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5232318
6 October 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4999885
18 August 2014 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4958496
1 December 2011 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4196932
27 September 2011 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4162977
28 February 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3954114
15 September 2010 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3849748
19 August 2008 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3303108
21 September 2005 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2498064
30 December 2004 Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2267788
1 October 2003 Construction Oversight · Hull Examination · COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2167438

Deficiency record · 29

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2025 Resolved
Found worn child PFD donning placard, replace placard.
Action required: 10 - Deficiency Rectified
Due 30 September 2025
Resolved 30 September 2025
Resolution: Owner/ Master Mounted new donning pacard prior to conclusion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2021 Resolved
Fixed fire extinguishing system shall be inspected annually. Vessels CO2 system has not been inspected since 2019. Ensure system is inspected and fully operational prior to getting underway with passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 22 October 2021
Resolution: Fire supression system tested all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 October 2021 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10, which requires both an annual inspection by a certified technician and monthly checks by the owner/operator. These monthly checks are not being performed/ Develop a system to conduct and log these monthly checks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2021
Resolved 28 December 2021
Resolution: They have developed a system to conduct and log these monthly checks.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 October 2021 Resolved
Vessels must comply with 47 CFR Part 80. All equipped radios must be operable onboard. Repair or replace the inoperable radio in pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2021
Resolved 28 December 2021
Resolution: Replaced the inoperable radio in pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 October 2020 Resolved
Vessel must carry at least one floating waterlight attached to the Ring Life Buoy, Waterlight had substantial crack in it causing it to no-longer meet required specifications for structural integrity. Replace Waterlight with approved equipment.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 October 2020 Resolved
Vessel must have lifejacket donning instruction placard posted in a conspicuous location,current placard is worn beyond legibility. Replace donning placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020 Resolved
Marine employers must establish random drug testing program for all crewmembers who perform duties and functions, required by the Vessel's Certification of Inspection, employer was unable to provide proof of one (01) crewmember's enrollment in random drug-testing pool. Provide evidence of crewmember's status in candidate pool.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2020 Resolved
Vessel must maintain a first aid kit as required in provided citation, kit had expired items. Restock kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Use of twist-on type electrical connectors may be used within an enclosure and the insulated cap must be secured to prevent loosening due to vibration, electrical connectors for water tank did not have means of securing wire nuts (i.e. electrical tape). Install in accordance with provided citation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2019 Resolved
Relocate the fire extinguisher in the concession stand so it is at the ext and the extiguisher in the change room so they are readily accessible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 September 2019 Resolved
Correct wiring in A/C space to meet standard for twist-on type wire nuts or use other approved commection type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2019 Resolved
relocate placard for life jacket donning instructions for both life jacket storage boxes to a conspicuous place visible to crew and passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 September 2019 Resolved
Correct TV power wiring in A/C space to meet standards for cable and wire for power and lighting circuits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 September 2019 Resolved
Install guards around propeller shafts in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 September 2019 Resolved
Install capture device for rudder room hatch cover to prevent loss of hatch cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 September 2019 Resolved
Replace faded sign on upper deck notifying passengers of 53 person limit for upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 September 2019 Resolved
The current lable for the fuel shutoff valve is hidden in the A/C closet which does not meet the intent of the regulations. The fuel shutoff station needs to be clearly marked for emergency situations which may require assistance from non-crewmembers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 September 2019 Resolved
The bilges and other spaces should have no excessive accumulation of oil, trash, deris, or other matter what might create a fire hazard, clog bilge pumping systems, or block emergency escape. The vissel is being utilized for storage of furniture, multiple 5 quart oil jugs next to the main engines, and various other maintenance supplies throughout the voids and engineering spaces. Crew stated the vessel was utilized to store these items so they wouldn't have to move it from the shed during flooding events.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 July 2018 Resolved
During ISE the Marine Inspector identified 6 buckled transverse frames in the void that is immediately aft of the collision bulkhead. Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered the cognizant OCMI may take vessel out of service to effect permanent repairs. Vessel owner shall provide the marine inspector with a written repair proposal to conduct permanent repairs for the six buckled frames. Conduct repairs after repair proposal has been approved to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 17 September 2018
Resolution: Received repair proposal and conducted inspection of 6 replaced frames. All satisfactory.
Lifesaving › Hand Flares › Approval
Issued 3 October 2017 Resolved
Vessel did not have Coast Guard approved distress signals. Vessel shall provide proper distress signals prior to getting underway.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 4 October 2017
Resolution: Owner rep provided verfication of adequate distress signals.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 September 2016 Resolved
Install missing plug cover starboard side steering room.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 3 October 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 August 2014 Resolved
Found no Coast Guard Light List on board. supply current Light list
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 23 September 2014
Resolution: copy of CG Light list is on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 August 2014 Resolved
Found child PFD storage area without donning placard. Provide appropriate placard.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 23 September 2014
Resolution: posted donning placard on lid of storage area.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 18 August 2014 Resolved
Found passenger count not kept on shore side. Provide satisfactory plan to USCG inspector.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 23 September 2014
Resolution: Master instituted a phone application where all 3 Captains are notified when one is getting u/w the other two will get time date and passenger count.
Personnel › Training › Fire Fighting Basic
Issued 18 August 2014 Resolved
Crew training has not been recorded in log book. Provide log book with crew training to include name, date, and description of training.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 23 September 2014
Resolution: Correct enteries are written in log book.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 August 2014 Resolved
Vessel drills has not been recorded in log book. Provide log book with abandon ship, man overboard, and fire drills to included; date of drill and description of drill.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 23 September 2014
Resolution: Provide log book w/ logged drills.
Engineering › Bilge Water Management System › Valve
Issued 18 August 2014 Resolved
Found engine room bilge suction check valve seized closed. Correct for future use.
Action required: 705 - Other - as specified
Due 23 October 2014
Resolved 30 September 2014
Resolution: Picture was emailed of corrected suction and strainer.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 September 2005 Resolved
Annual servicing not completed. Provide proper documentation of annual service.....
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 September 2005 Resolved
Annual servicing not completed. Provide proper documentation of annual service.....
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2005

Casualty record · 1

28 February 2011Routine · role: Involved in a Marine Casualty · activity 3954114
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.