CHASE-N-FINS

CHASE-N-FINS is a 1977 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2004, most recently in August 2024, along with 46 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 2004 to 2024. Most recent: inspection, 12 August 2024.

Built
1977
Last inspected
12 August 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WD16416
711885
Flag
UNITED STATES
367718480
Maury page id
psix-711885

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (2004–2024)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.3 ft × 14.8 ft × 7.5 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR2120MMSI 367718480 · active · compulsorily equipped · granted 29 May 2026, expires 29 May 2036
WDI6416MMSI 367718480 · expired · voluntarily equipped · granted 2 March 2016, cancelled 2 May 2026
WDC9406MMSI 367101830 · expired · voluntarily equipped · granted 24 March 2006, cancelled 28 May 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 33

12 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7979573
21 February 2024 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7868260
9 January 2024 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7870869
1 May 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678857
1 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429439
9 February 2022 Hull Examination · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393385
14 March 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156054
21 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6941807
6 January 2020 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6883739
20 May 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6669264
18 June 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6448640
5 April 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6386162
1 January 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6331036
9 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6144638
6 March 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6099560
11 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5874714
3 March 2016 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826137
11 September 2015 Hull Examination · Internal Structural Exam · Examination of Repairs · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5755607
29 July 2015 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5200284
28 July 2015 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5205851
21 May 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4815713
16 May 2012 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4296947
13 September 2011 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4149333
31 July 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3277991
22 October 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3082528
27 September 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3067291
10 September 2007 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3277994
4 September 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3048644
6 June 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2640488
13 March 2006 Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2609154
19 October 2005 Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2517704
9 August 2005 Hull Examination · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2584424
14 October 2004 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2220920

Deficiency record · 46

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2024 No resolution recorded
TO MAINTAIN A VALID CERTIFICATE OF INSPECTION, YOU MUST COMPLETE YOUR ANNUAL INSPECTION WITHIN THE THREE MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. VESSEL WAS NOT INSPECTED WITHIN THE THREE MONTHS BEFORE OR AFTER 18 MARCH 2024.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2024 No resolution recorded
A VESSEL THAT IS EXPOSED TO SALTWATER MORE THAN THREE MONTHS IN ANY 12 MONTH PERIOD SINCE THE3 LAST EXAMINATION MUST UNDERGO A DRYDOCK EXAMINATION AND INTERNAL STRUCTURAL EXAMINATION AT LEAST ONCE EVERY TWO YEARS.VESSEL DID NOT RECEIVE A DRYDOCK EXAMINATION PRIOR TO THE DROP DEAD DATE OF 28 FEBRUARY 2024.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2023 Resolved
At every vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. The bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard. Vessel was found to have an excessive amount of oil in the engine space. Oil was permeating and saturating the bilges, bulkheads, overhead and equipment.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 May 2023
Resolved 14 June 2023
Resolution: engine room was cleaned of oil
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2023 Resolved
Operator shall be prepared to conduct machinery tests and have vessel ready for inspection. Vessels main propulsion machinery (engines) are not operationally ready for inspection and not functioning properly, as designed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 May 2023
Resolved 14 June 2023
Resolution: engines were tested for 10 minutes
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2023 Resolved
A vessel of at least 26 feet a visual and audible alarm must be provided at the operating station to indicate a high water lever in each unmanned space. Vessels visual bilge alarm was not operable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 May 2023
Resolved 14 June 2023
Resolution: replaced bilge visual alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2023 Resolved
At every vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected... all required guards and protective devices must be in satisfactory condition. Vessel was missing protective guard on both main diesel engine.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2023
Resolved 21 June 2023
Resolution: provided photo evidence of installed machinery guards
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2023 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel has oil ladened loose dead-ended wires in engine room. Remove wiring or relocate to a terminate in a junction box & remove oil residue.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2023
Resolved 14 June 2023
Resolution: dead end wires were capped
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 June 2022 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has not completed an Annual Inspection and is restricted from operating as a passenger vessel until a satisfactory Annual Inspection is completed with Sector Mobile.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2022
Resolution: Vessel completed SAT annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022 Resolved
Address hole in the port side console area
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2022
Resolution: received photo, hole repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2021 Resolved
Vessel is required to have annual servicing of firefighting equipment. Vessel was unable to provide documentation of annual servicing. Conduct annual servicing in the presence of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 31 March 2021
Resolution: Witness sat test with Hiller technician.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2021 Resolved
Life jackets are required to have retro reflecive tape. Three lifejackets were found with deteriorated retroreflective tape. Replace or renenw life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 18 March 2021
Resolution: Two new adult life jackets were placed into service, and the retroreflective tape on one child life jacket was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2021 Resolved
Ring life buoy requires lifeline. Ring life bouy was not fitted with a lifeline. Fit lanyard on ring life bouy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Life ring had life line spliced onto life ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Fuel tank vents are required to have frame screens or arrestor. Flame screen or arrestor not fitted. Fit flame screen or arrestor.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Added flame arrestors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2021 Resolved
Visual indication must be provided at operating station to indicate when any bilge pump is operating. Light indicator was inoperable. Replace or repair indicator light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Visual indicator was operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Piping above 150 F must be suitably insulated. Lagging on starboard engine is hanging off the exhaust pipe. Reattache starboard engine exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Insulation added and satisfactory
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2021 Resolved
Electrical equipment must be maintained to protect from electrical hazards. Vessel had multiple dead-end wires in the battery space. Remove dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Dead end wires removed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2021 Resolved
Vessel must carry adequate and up-to-date charts. Charts onboard are from 2016. Provide or update charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 31 March 2021
Resolution: Procured updated charts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 May 2019 Resolved
Light lanyard attached to grab line in stead of around body of life ring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 28 May 2019
Resolution: Owner submitted photograph of appropriate life ring light lanyard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2019 Resolved
Loose and dead end wires in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 20 May 2019
Resolution: Crew member bundled wires and removed dead ends.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2019 Resolved
Worn retro on 16 adult life vests and 3 child life vests.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2019
Resolved 20 May 2019
Resolution: Received photograph addressing the retroflective tape on the 16 adult and 03 child life jackets. Accepted the photographs as objective evidence to clear.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2019 Resolved
Remount electrical junction box hanging by wires beneath head.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 June 2019
Resolved 20 May 2019
Resolution: re-mounted junction box to bulkhead on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 24 April 2017 Resolved
Provide updated charts for area of operation IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 9 May 2017
Resolution: Updated navigation charts provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 April 2017 Resolved
Provide current copy of NAVRULES IAW 33 CFR 83.01.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 9 May 2017
Resolution: Updated Navigation rules provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 April 2017 Resolved
Replace life ring bouy waterlight lanyard IAW 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 9 May 2017
Resolution: Lanyard properly attached to floating waterlight.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 April 2017 Resolved
Provide two portable lights on board IAW 46 CFR 183.430.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 9 May 2017
Resolution: Working portable lights provided.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 24 April 2017 Resolved
Ontain radio operator permit for master IAW 47 CFR 80.159.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 11 May 2017
Resolution: Updated Marine Operators Permit provided.
Documentation › Logs/Records › Drug Test Records
Issued 18 April 2016 Resolved
EAP training for supervisor and crew was not provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 11 May 2016
Resolution: EAP training for supervisor and crew was provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2016 Resolved
Wiring for fwd bilge pump has wrong wire connectors. Not sealed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 11 May 2016
Resolution: Sealed and provided proper wire connectors for fwd bilge pump.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2016 Resolved
Anchor light was not working and could not be seen from stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 11 May 2016
Resolution: Extended the length of anchor light.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 29 July 2015 Resolved
Stbd engine is internally broke. Make repairs as needed IAW 46 cfr 182.200 / 220
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2015
Resolved 31 July 2015
Resolution: Stbd engine repaired and inspected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 May 2014 Resolved
Starboard emergency fuel shutoff does not close completely, adjust to ensure proper closure of fuel shutoff valve per 46 CFR 182.20-40(b)(3)
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 13 June 2014
Resolution: Adjusted linkage and proved proper operation.
Engineering › Fuel Oil Service System › Hose
Issued 12 May 2014 Resolved
Fuel hoses are not SAE J 1942 compliant, either replace with SAE J 1942 compliant hose or add approved fire sleeve per 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 18 June 2014
Resolution: Provided appropriate fire sleave with supporting documentation.
Navigation › Piloting/Steering › Marine Charts
Issued 12 May 2014 Resolved
Provide updated charts for area of operation per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 13 June 2014
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 1 May 2006 Resolved
Post emergency instruction list 46CFR185.510
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Posted emergency instruction list
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 May 2006 Resolved
Provide US Coast Pilot and Light List 46CFR 184.420
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided US Coast Pilot and Light List
Documentation › Markings/Placards › Capacity Marking
Issued 1 May 2006 Resolved
Mark upper operating station, "Crew Only" 46CFR 185.602(g)
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Marked upper operating station, "Crew Only"
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 May 2006 Resolved
Provide 02 Adult life jackets marked with vessel name. 46CFR180.71
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided 02 adult life jackets and marked with the vessel name.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 May 2006 Resolved
Provide lifejacket donning placard for jacket type onboard 46CFR185.516
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided correct lifejacket donning placard
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 May 2006 Resolved
Provide waterlight for ing buoy and properly attach with clip. 46CFR180.70
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided waterlight for ring bouy and properly attached with clip
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2006 Resolved
Provide metal supports every 24 inches for wiring in battery room 46CFR 183.340
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided metal supports every 24 inches for wiring in battery room
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 May 2006 Resolved
Label lifejacket storage area for lifejacket number. 46CFR185.604
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Labeled lifejacket storage area for number of lifejackets
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 May 2006 Resolved
Splice lifeline to lifering. 46CFR180.70
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Spliced lifeline to lifering
Documentation › Markings/Placards › Oil Discharge Placard
Issued 1 May 2006 Resolved
Mount oil pollution an MARPOL V placard 33CFR151.59 and 33CFR 155.450
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Mounted oil pollution and MARPOL V placards
Engineering › Steering Gear System › Fastener
Issued 1 May 2006 Resolved
Remove excess play from through bolts on steering jockey arm assembly and hydraulic ram assembly. 46CFR182.610
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Removed excess play from through bolts on steering jockey arm assembly and hydraulic ram assembly
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 1 May 2006 Resolved
Provide adequate engine room ventilation not blocked by stairs 46 CFR 182.465
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Provided adequate engine room ventilation
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 1 May 2006 Resolved
Double nut bolts on port and starboard stuffing boxes 46CFR176.800
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Doubled nut on starboard stuffing box. Changed nut to appoved locking nut on port stuffing box, because there was not enough bolt left to attach two bolts.