Records from 1985 to 2025. Most recent: inspection, 22 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 52
22 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8191944
19 September 2024
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8108533
21 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7798060
24 August 2022
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7542663
2 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7302737
17 June 2020
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6967844
20 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6929965
22 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6792540
30 August 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6528344
24 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6236146
28 September 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6012137
27 August 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4965222
29 July 2011
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4098135
13 July 2009
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3526575
5 August 2008
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3289871
21 July 2008
Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 3274351
9 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3202592
5 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3199366
9 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2925805
3 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2734922
26 June 2006
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2691908
26 October 2005
Simplified Stability Test
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2522321
15 August 2005
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2463725
3 May 2005
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2348403
9 August 2004
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2161035
29 June 2004
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2115381
29 September 2003
Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 1917148
29 September 2003
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1965524
28 April 2003
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1782177
16 April 2001
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1401443
28 April 2000
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1365692
7 May 1999
Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1369194
8 June 1998
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 793021
2 September 1997
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 761931
24 August 1997
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 196099
23 April 1997
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1421336
8 April 1996
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079471
27 April 1995
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1371057
28 March 1995
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1422486
30 April 1994
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1450872
30 April 1993
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1147456
30 April 1992
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1270790
30 April 1991
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1217378
30 April 1990
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 867999
27 April 1990
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1212871
13 July 1989
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1350314
28 June 1989
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 896407
9 June 1988
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1200643
11 May 1987
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1023690
11 May 1987
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1331825
26 June 1986
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 996244
14 June 1985
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 981949
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 March 2020
Resolved
Hull aft port side beside exhuast pipe wasted. Vessel rep shall crop and renew wasted area to good steel prior to vessel leaving dry dock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 7 April 2020
Communications › Radio Communications › EPIRB
Issued 28 September 2016
Resolved
The EPIRB battery is expired. Replace battery and conduct satisfactory operational test. Vessel's route is restricted to within 3 miles from shore until corrected. (46 CFR 185.728)
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 12 October 2016
Communications › Radio Communications › EPIRB
Issued 28 September 2016
Resolved
The EPIRB hydrostatic release unit (HRU) is expired. Replace HRU and properly mark for expiration. Vessel's route is restricted to within 3 miles from shore until corrected. (46 CFR 185.740(b))
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 12 October 2016
Communications › Radio Communications › EPIRB
Issued 28 September 2016
Resolved
The EPIRB's NOAA registration (as indicated on the applied decal) is expired. Attach current registration decal. Vessel's route is restricted to within 3 miles from shore until corrected. (46 CFR 180.64)
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 12 October 2016
Lifesaving › Lifefloat › Painter
Issued 27 August 2014
Resolved
Lifefloat painters not attached to vessel. Properly re-attach lifefloat painters. (46CFR180.175(f)(3)).
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2014
Resolved 27 August 2014
Resolution: Corrected during inspection.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 1 August 2011
Resolved
Hotline number was not displayed; company drug and alcohol policy was not made available to crew. Poster was provided to marine employer to meet the requirement to display a drug/alcohol addiction hotline number. Marine employer must post company policy or have each employee sign a copy of the policy attesting that they have read and agree to adhere to the policy.
Due 31 August 2011
Resolved 24 August 2011
Resolution: EAP poster is on display and policy letter has been signed by employees.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 August 2011
Resolved
Supervisor and crew training were not conducted/documented.
Due 31 August 2011
Resolved 14 October 2011
Resolution: DER obtained video from the library and presented to crew.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 13 July 2009
Resolved
The stern light is hull grounded and is out of compliance with 46 CFR 183.370. Operator shall install proper ground return wire in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 13 July 2009
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 July 2009
Resolved
Vessel has one child sized lifejacket on board. Operator shall provide no less than 3 child sized type 1 life jackets on board in accordance with 46 CFR 180.71 (b) prior to carrying any passengers who weigh less than 90 pounds.
Action required: 705 - Other - as specified
Due 13 July 2009
Resolved 13 July 2009
Engineering › Bilge Water Management System › Pump
Issued 13 July 2009
Resolved
Operator shall provide on board 1 hand portable bilge pump in accordance with 46 CFR 182-25-5(e)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2009
Resolved 13 July 2009
Engineering › Lubricating Oil Service System › Gauge
Issued 13 July 2009
Resolved
Make operational the main engine lubricating oil pressure gage at the operating station in accordance 46 CFR 182.20-5 (g)
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 18 June 2010
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 July 2009
Resolved
Remove twist on wire connectors for cabin lighting fixture at operating station and properly wire in accordance with 46 CFR 183.05-50
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 18 June 2010
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 May 2008
Resolved
Remove all oil and debris from bilge.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 8 June 2008
Resolution: Bilge cleaned.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 5 May 2008
Resolved
Properly secure throttle cable to main diesel engine.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 8 May 2008
Resolution: Properly installed throttle cable.
Engineering › Fuel Oil Service System › Hose
Issued 5 May 2008
Resolved
Properly install chaffing gear on fuel line in engine compartment.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 8 May 2008
Resolution: Installed chaffing gear as required.
Engineering › Steering Gear System › Bracket/Clamp
Issued 5 May 2008
Resolved
Prove proper operation of steering system.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 6 May 2008
Resolution: Modified emergency tiller to operate properly.
Stability › Watertight Integrity › General
Issued 5 May 2008
Resolved
Properly seal fuel cap to maintain watertight integrity.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 8 May 2008
Resolution: Properly sealed fuel fill cap.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 5 May 2008
Resolved
Replace cracked windshield in accordance with 46CFR177.1010, 177.1020
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 8 May 2008
Resolution: Replaced cracked windshield
Electrical › Lighting (service) › Grounding Conductor
Issued 5 May 2008
Resolved
Provide proper grounding of installed lighting system.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 5 August 2008
Resolution: Removed affected ground
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2008
Resolved
Provide lifesaving maintenance log book.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 5 August 2008
Resolution: Provided updated lifesaving book
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 May 2007
Resolved
Install f/o remote shut-off.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Resolution: Vessels reps installed a shut off cable, tested sat.
Engineering › Fuel Oil Service System › Piping
Issued 9 May 2007
Resolved
F/O leak return hose from pump-copper seal leaking.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Resolution: Vessels reps replaced the 2 copper seals on the return pipe, tested sat.
Lifesaving › Buoyant Apparatus › Marking
Issued 9 May 2007
Resolved
Life floats are 15 passenger each, both rafts have a max 30 passengers, COI states 32 pob, vessel can only carry 28 passengers (2) crew with current life floats. Till warm water 15 May.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 10 January 2008
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 August 2006
Resolved
Propeller shaft packing is starting to look worn and appears to be misaligned. Owner states that it is monitored and occasionally need to be tightened. Informed owner that the entire packing arrangement will need to be replaced at the end of the operating season.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2007
Resolved 10 January 2008
Resolution: Owner replaced worn packing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2006
Resolved
Remove dead end wires from panel in the head. Cover terminal blocks in head.
Condition: Improper/Lack of Maintenance
Due 30 July 2006
Resolved 3 August 2006
Resolution: Removed all dead end/unused wires.
Engineering › Steering Gear System › Linkage
Issued 26 June 2006
Resolved
Prove proper operation of the emergency steering gear.
Condition: Design Flaw
Due 27 July 2006
Resolved 3 August 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 June 2006
Resolved
Sewage tank vent is kinked and needs to be repaired.
Condition: Design Flaw
Due 27 July 2006
Resolved 3 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 15 August 2005
Resolved
Raw water pump leaking through the cam hold down bolt on the side of the pump housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 11 October 2005
Resolution: Vessels reps repaired the raw water pump.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 August 2005
Resolved
Sewage discharge hose kinked and leaking, and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 11 October 2005
Resolution: Vessels reps replaced leaking sewage hose.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 August 2005
Resolved
Raw water intake hose before the R/W pump is kinked and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 11 October 2005
Resolution: Vessels reps replaced raw water hose.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 August 2005
Resolved
New hydraulic hose's for steering system need to have chaffing gear installed due to chafe on the frames, prevent future steering casualty.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 11 October 2005
Resolution: Vessels reps added chaffing gear to the chaffing areas of the hose run.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 15 August 2005
Resolved
Fresh water gauge on the console in the pilot house is not working, needs to be replaced, vessels rep's stated one is on order.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 11 October 2005
Resolution: Vessels reps repaired faulty temp gauge.
Construction/Loadline › Hull › Bottom Plating
Issued 3 May 2005
Resolved
Irish Drifter was ut'd and found that the mid body of the hull is approx .110 to .130 which is wasted 1/8" plating, Coast Guard engineers had MSU Toledo take hull measurements to determine if the hull was proper for the size and type vessel, after review of the drawings MSC engineers determined the hull to be to thin and should be above .150 and in need of replacement.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 21 September 2005
Resolution: Hull was replaced in all area''s of concern, vessel was inspected and tested in sea trials with sat results.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2005
Resolved
Properly secure bilge alarm wire every 24in with metal ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 21 September 2005
Resolution: Wire was corrected with steel ties.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 May 2005
Resolved
Properly install sewage tank inside bracket.
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 21 September 2005
Resolution: Tank is secured properly.
Communications › Radio Communications › EPIRB
Issued 29 June 2004
Resolved
EPIRB battery needs to be replaced prior to 01 JUL 04.
Due 1 July 2004
Resolved 2 July 2004
Engineering › Steering Gear System › Rudder Stock
Issued 29 June 2004
Resolved
Rudder post cracked, required to be replaced prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2004
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 June 2004
Resolved
Install flame screens prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2004
Engineering › Bilge Water Management System › Hose
Issued 29 June 2004
Resolved
Fix leaking bilge pump hose prior t carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2004
Lifesaving › Lifefloat › Paddle
Issued 29 June 2004
Resolved
Ensure paddles are properly secured and marked with vsl name.
Due 29 July 2004
Resolved 2 July 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 29 June 2004
Resolved
Sewage tank not properly secured below decks.
Due 29 July 2004
Resolved 9 August 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 June 2004
Resolved
Provide cover for junction box in pilot house overhead.
Due 29 July 2004
Resolved 2 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2004
Resolved
remove dead end wires from overhead in pilot house.
Due 29 July 2004
Resolved 2 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 June 2004
Resolved
Remove life jackets from current storage place/method and install hooks for overhead instead of overhead wiring.
Due 29 July 2004
Resolved 2 July 2004
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 29 June 2004
Resolved
Secure electrical box on front of main engine.
Due 29 July 2004
Resolved 9 August 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2004
Resolved
Lower high level bilge alarm.
Due 29 July 2004
Resolved 2 July 2004
Documentation › Certificates/Documents › FCC SSL
Issued 29 June 2004
Resolved
Obtain valid FCC station license.
Due 29 July 2004
Resolved 9 August 2004
Engineering › Bilge Water Management System › Pump
Issued 29 June 2004
Resolved
Properly mount bilge pumps.
Due 1 February 2005
Resolved 9 August 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 June 2004
Resolved
Install valve for through hull fitting.
Due 1 February 2005
Resolved 14 June 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 June 2004
Resolved
Conduct man-overboard drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 29 June 2004
Resolved
Properly label switches in pilot house.
Due 29 July 2004
Resolved 2 July 2004
Lifesaving › Buoyant Apparatus
Issued 28 April 2003
Resolved
STENCIL NAME OF VESSEL ON LIFE FLOAT AND FLOATING LIGHT.
Due 28 April 2003
Resolved 28 April 2003
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 April 2003
Resolved
STENCIL NAME OF VESSEL ON LIFE JACKETS.
Due 28 April 2003
Resolved 28 April 2003
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2003
Resolved
REMOVED ONE LIFE JACKET FROM SERVICE NEED TO REPLACE.
Due 28 April 2003
Resolved 28 April 2003
Engineering › Bilge Water Management System
Issued 28 April 2003
Resolved
REMOVE OILY WATER FROM BILGE.
Due 28 April 2003
Resolved 28 April 2003
Communications › Automatic Identification System (AIS)
Issued 28 April 2003
Resolved
THE EPIRB IS NOT REGISTERED WITH NOAA. OWNER MUST REGISTER EPIRB.
Due 28 May 2003
Resolved 5 May 2003
Engineering
Issued 7 May 1999
Resolved
REPLACE BRACKET AND REPAIR CABLE FOR ENGINE SHUTDOWN AND SHOW PROPER OPERATION TO MARINE INSPECTOR.
Condition: Unknown
Due 9 June 1999
Resolved 7 June 1999
Documentation
Issued 7 May 1999
Resolved
PROVIDE DOCUMENTATION OF VESSEL TO CG MARINE INSPECTOR.
Condition: Unknown
Due 16 June 1999
Resolved 15 June 1999
Engineering
Issued 7 May 1999
Resolved
INSTALL BARBED FITTING ON RETURN FUEL LINE IN LIEU OF CURRENT COPPER TUBINGCONNECTION.
Condition: Unknown
Due 9 June 1999
Resolved 7 June 1999
Navigation
Issued 8 June 1998
Resolved
REPLACE RUDDER POST BASE PLATE AND 1 BROKEN BOLT ON PLATE
Condition: Unknown
Due 15 June 1998
Resolved 23 June 1998
Construction/Loadline
Issued 28 March 1995
Resolved
CROP AND RENEW AS SPECIFIED THE BULKHEAD AFT OF THE ENGINE.
Condition: Unknown
Due 28 April 1995
Resolved 1 May 1995
Construction/Loadline
Issued 28 March 1995
Resolved
REPAIR AS ORIGINAL THE FRAMING FORWARD OF THE FUEL TANK.
Condition: Unknown
Due 28 April 1995
Resolved 1 May 1995
Documentation
Issued 28 March 1995
Resolved
PROVIDE NEW BLUEPRINTS SHOWING FRAMING MODIFICATIONS, RUDDER_x001C_ MODIFICATIONS AND PLATE CHANGES.
Condition: Unknown
Due 28 April 1995
Resolved 1 May 1995
Construction/Loadline
Issued 28 March 1995
Resolved
WELD ALL BOLT HOLES IN HULL IN FORWARD COMPARTMENT WHERE SIGNS WERE LOCATED.
Condition: Unknown
Due 28 April 1995
Resolved 1 May 1995
Accommodation/Occupational Safety
Issued 28 March 1995
Resolved
REPAIR ROOFING OVER PASSENGER DECK.
Condition: Unknown
Due 28 April 1995
Resolved 1 May 1995
Construction/Loadline
Issued 30 April 1994
Resolved
REPAIR HOLE/CRACK BY RUDDER POST IN HULL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Construction/Loadline
Issued 30 April 1994
Resolved
PROVIDE ALL INFORMATION, INCLUDING SCALE DRAWINGS WEIGHTS OF MATERIALS REMOVED AND REPLACED FOR STABILITY TEST.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Engineering
Issued 30 April 1994
Resolved
PROVIDE DRAWINGS OF ENGINE MOUNTS FOR NEWLY INSTALLED VOLVO PENTA ENGINE.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Fire Fighting
Issued 30 April 1994
Resolved
PROVIDE 1 B-II EXTINGUSHER.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Documentation
Issued 30 April 1994
Resolved
PROVIDE CURRENT VESSEL DOCUMENTATION STICKER
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Documentation
Issued 30 April 1994
Resolved
PROVIDE CURRENT FCC STATION LICENSE
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Documentation
Issued 30 April 1994
Resolved
PROVIDE CURRENT GREAT LAKES RADIOTELPHONY CERT.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Lifesaving
Issued 30 April 1991
Resolved
COMPLETE U/W DRILLS NLT 10 MAY 91.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Engineering
Issued 28 June 1989
Resolved
REMOVE EXCESSIVE OIL FROM E/R BILDGE IAW 46CFR176.25-10 (7) B. WILL TEST BILGE PUMPS AT THAT TIME
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Electrical
Issued 28 June 1989
Resolved
REMOVE DEADEND WIRES FROM STEERING/INSTRUMENT STATION IAW 46CFR183.01-15(A)
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 28 June 1989
Resolved
INSTALL PENDANTS OF FWD B/A IAW 46CFR 160.010-3 (G)
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Navigation
Issued 11 May 1987
Resolved
PROVIDE MEANS TO OPERATE EMERGENCY STEERING WITH THE AFTER HATCH IN PLACE.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Engineering
Issued 11 May 1987
Resolved
REPLACE PVC ELBOW IN FUEL VENT LINE WITH A NON FERROUS METAL FITTING
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987