← All vessels
ONEGO GLOMMA
ONEGO GLOMMA is a 2002 public freight. The Coast Guard has recorded 29 inspections since 2004, most recently in June 2026, along with 37 deficiencies and 5 operational controls.
Records from 2004 to 2026. Most recent: inspection, 27 June 2026.
- Built
- 2002
- Last inspected
- 27 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 37 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9294977 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2BQ2
712048
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-712048
Inspections, by type
…with no type recorded4
Years with a record
10 calendar years (2004–2026)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7767 - Convention (Subpart B), Gross Ton
10649 - Dead Weight, Metric Ton
7347 - Displacement, Metric Ton
3856 - Convention (Subpart B), Net Ton
10649 - Dead Weight, Metric Ton
7347 - Displacement, Metric Ton
3856 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
27 June 2026
PSC A
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8416962
7 April 2026
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8343996
7 January 2026
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8291284
9 November 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8266261
28 October 2025
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8259816
23 October 2025
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8254466
25 August 2025
Deficiency Check · PSC A
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8214325
5 August 2025
Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8202289
20 May 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8134946
26 November 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8040402
16 November 2024
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8035755
13 August 2024
PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7975303
5 June 2022
PSC A
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7468561
21 May 2020
PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6956736
18 February 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4246828
8 December 2008
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3376739
16 January 2008
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3131522
13 January 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3129621
25 November 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3103793
23 November 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3103316
5 September 2007
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3050655
5 September 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3050681
24 March 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2894072
11 January 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2854042
2 October 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2505265
21 December 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2263315
30 August 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2192227
23 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2173765
23 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2177206
Deficiency record · 37
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 23 October 2025
Resolved
The master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications at all times. PSCO observed vessel's BWMS not within manufacturer's specifications since May 2025. Vessel is to not discharge untreated ballast.
33CFR151.2025(a)(1)
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 October 2025
Resolved
All ships 500 gross tonnage and upwards shall have... rudder indicators to determine and display rudder angle, readable from the conning positions. PSCO observed starboard conning position rudder indicator display incorrect angle.
74SOLAS(20) V/19.2.5.4
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 October 2025
Resolved
Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. PSCO observed gas sampling point for cargo hold no.2 unable to seal.
74SOLAS(01) II-2/5.1.4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 25 August 2025
Resolved
The company should clearly define and document the master’s responsibility with regard to: 1. implementing the safety and environmental-protection policy of the company. 2. motivating crew in the observation of that policy. The operational nature of deficiencies 02,03 04 and 05. provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report, satisfactory to the OCMI must be submitted, prior to clearance of this deficiency. 74SOLAS(2020)
IX/3.1
ISM Code 2018
Part A 5.1
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 August 2025
Resolved
Each fire drill shall include: .3 checking of fireman's outfits and other personal rescue equipment; 4. checking of relevant communication equipment. PSCO observed 02 fire drills conducted. Fire team was unable and unaware on proper donning of SCBA. Lack of communication between the fire team and bridge and lack of knowledge of fire fighting equipment located in galley.
74SOLAS(2024)
III/19.3.5.2
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 August 2025
Resolved
Muster stations shall be provided close to the embarkation stations. Each muster station shall have sufficient clear deck space to accommodate all persons assigned to muster at that station, but at least 0.35m.Muster stations shall be provided close to the embarkation stations. Each muster station shall have sufficient clear deck space to accommodate all persons assigned to muster at that station, but at least 0.35m². PSCO observed muster station obstructed by scaffolding blocking more than 50% of the muster station.
74SOLAS(2024)
III/11.2
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 August 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 August 2025
Resolved
On-board training in the use of the ship's life-saving appliances, including survival craft equipment, and in the use of ship's fire -extinguishing appliances shall be given as soon as possible... PSCO questioned 04 personnel about proper wearing of immersion suits. All crew members responded with no life-jacket required. Immersion suits did not meet the requirement or having fittings to not require life jackets.
74SOLAS(2024) III / 19.4.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 August 2025
Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Doors and door frames in "A" class divisions shall be constructed of steel. PSCO observed that the paint locker door was not able to maintain an "A" class boundary due to handle and fit being loose and door seal completely painted over.
74 SOLAS (2001) II-2 / 47.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 August 2025
Resolved
Except as provided in paragraph 4, two means of escape shall be provided from each machinery space of Category A. In particular one of the following provisions shall be complied with: PSCO observed that the engine control room had ladders on the main deck blocking the escape hatch.
74 SOLAS (2024) III/19.4.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 August 2025
Resolved
Below the lowest open deck the main means of escape shall be a stairway and the second escape may be a trunk or a stairway. PSCO observed that the emergency escape from provision store had multiple cases of water blocking the escape trunk.
SOLAS (2001) II-2/45.1.2.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 5 August 2025
Resolved
The company should clearly define and document the master's responsibility with regard to : 1. Implementing the safety and environmental-protection policy of the company. 2. motivating crew in the observation of that policy. The Chief Engineer removed the International Shore connection from its intended location to connect the seawater pump and freshwater generator to replace a portion of wasted piping in the engine room. The Chief Engineer failed to notify the Master, Company, Class Society, or the Flag State. The vessel failed to fully implement the requirements of the SMS as evident by deficiencies 02, 04, 05, 07, 09, 12, and 13. An external audit is required. 74SOLAS (20) IX/3.1 ISM Code 2018 Part A 5.1
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 5 August 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. PSCO observed the vessel's international shore connection being used in the engine room to connect the seawater pump to the fresh water generator in order to by-pass wasted piping. Chief Engineer stated it was installed on the seawater pump during the voyage from New Orleans to Lake Charles. 74 SOLAS (20) II-2/14.1.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board due regard being paid to moving parts, hot surfaces and other hazards. After being manually shut down, the emergency generator will restart on its own with no known cause for its restart, posing a hazard to any persons that may be working on the prime mover at the time it automatically starts.74SOLAS(20)
II-1/26.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed temporary repair on a high voltage line to the gantry crane posing a hazard to crew members and personnel. Use of damaged electrical cable is prohibited.74SOLAS(04)II-1/45.1.3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 August 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids ...means shall be provided to control leaks of flammable liquids and limit the accumulation of flammable vapors. PSCO observed approximately 40 containers of flammable liquids (paint) outside of paint locker in the bosun store. 74SOLAS(20)II-2/4.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 August 2025
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks... PSCO observed the PS main deck ladder well door was held open with a metal pipe.74SOLAS(01)II-2/47.2
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 5 August 2025
Resolved
All ships officers concerned with the operation and/or maintenance of steering gear shall be familiar with the operation of the steering systems fitted on the ship and with the procedures for changing from one system to another. PSCO observed Chief Engineer and Second Engineer unable to perform loss of power and low hydraulic oil alarm tests on the steering gear.74SOLAS(20)V/26.3.2
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 5 August 2025
Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed, including remotely located survival craft carried in accordance with regulation 31.1.4, additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch or working at those locations at any time. PSCO observed no immersion suits in the engine control room.74SOLAS(20) III/32.3.3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed a removed section of wasted piping, on the deck of the engine room, intended to connect the seawater pump to the freshwater generator. The Chief Engineer failed to notify the Master, the Company, the Classification Society, or the Flag State that the system was inoperable. 74SOLAS(20)II-1/26.1
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 August 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger. PSCO observed wastage adjacent STBD accommodation ladder on poop and A deck. 74SOLAS(20)I/11(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 August 2025
Resolved
The opening below the lowest course of the guard rails shall not exceed 230 mm (9 inches). PSCO observed lower guard rail PS close to midships was cracked. ILLC as modified
2003 Reg 25.3
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 5 August 2025
Resolved
The Administration shall be satisfied that adequate arrangements are in in place to ensure that the performance of the equipment required by this chapter are maintained. PSCO observed the gyrocompass door propped open. [name withheld] stated the door was propped open to provide ventilation to the gyrocompass as advised by a technician due to overheating.74SOLAS(20)V/16.1
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 5 August 2025
Resolved
The master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications at all times of discharge into the waters of the United States. PSCO observed vessel's ballast water treatment system has not been within manufacturer specifications since May 2025. Vessel is not authorized to discharge untreated ballast in US Waters. 33CFR151.2025(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2024
Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. MAIN ENGINE JACKING GEAR AUTOMATIC POWER SHUTOFF NOT FUNCTIONING PROPERLY. 74SOLAS(04)II-1/31.1 15AC
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 August 2024
Resolved
EVERY FUEL OIL PIPE, WHICH IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE, SETTLING, OR DAILY SERVICE TANK, SITUATIONED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE CONCERNED IN THE EVENT OF A FIRE OCCURING IN THE SPACE IN WHICH SUCH TANKS ARE SITUATED. EMERGENCY GENERATOR FUEL SHUT OFF VALVE DID NOT ACTUATE FROM THE EMERGENCY SHUT OFF POSITION. SOLAS 74/78 (2001 CONS. ED.) II-2/2.5
Operations/Management › Pollution › Retention of Oily Mixture
Issued 13 January 2008
Resolved
13JAN2008-Vessel's bilges have approximately one cubic meter of oil.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 January 2008
Resolved
13JAN2008-Vessel displays a ground on the 24V electrical system. Class issued condition of class to be rectified by next US Port.
Lifesaving › Inflatable Liferafts › Painter
Issued 13 January 2008
Resolved
13JAN2008-Vessel's forward life raft painter is not, by any means, attached to the vessel.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 13 January 2008
Resolved
13JAN2008-Forward life raft is not stowed in a readily accessible location or arrangement to render it available for easy launch in five minutes.
Stability › Watertight Integrity › General
Issued 13 January 2008
Resolved
13JAN2008-Vessel's stern has damage on the aft most rib.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 13 January 2008
Resolved
13JAN2008-Vessel does not have a block diagram in it's emergency steering gear compartment.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 January 2008
Resolved
13JAN2008-02 crewmembers did not have their whistles attached to their PFD's.
Engineering › Steering Gear System › Pump
Issued 25 November 2007
Resolved
While operating in the Lower Mississippi River, the vessel experienced a steering loss at mm 163.5.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 11 January 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 11 January 2007
Resolved
Vessel was operating an unapproved heating system in the engine room for the forward piping tunnel. A 55 gallon drum of diesel fuel that was used to fuel a space heater was tied to hand railing next to the heater presenting a fire hazard. 55 gallon drum was removed on the spot.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 2 October 2005
Resolved
Vessel must provide ballast water management plan specific to vessel prior to next U.S. port after sailing foreign.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.