Records from 2005 to 2025. Most recent: inspection, 6 June 2025.
Inspection history · 19
6 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8155391
26 July 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7969613
21 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7912300
13 May 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7911690
5 February 2024
Drydock Extension · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7860992
28 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7754853
5 August 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7522358
15 June 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7472076
24 February 2022
Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7401624
16 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7278926
12 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6977748
13 November 2018
Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6579766
28 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6525517
6 July 2018
Deficiency Check · Initial Certification · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6477760
14 September 2017
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6267236
20 June 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6188139
1 August 2011
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4117121
20 November 2008
Uninspected Other
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3366626
21 June 2005
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2399266
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2025
Resolved
Vessel required 12 flares (6 day and 6 night) for Oceans route. Vessel had 3 expired flares on board, and 9 more expire in July 2025. Provide 12 flares. Vessel restricted to lakes, bays and sounds route within 3 miles of shore.
Action required: 705 - Other - as specified
Resolved 13 August 2025
Resolution: Completed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2025
Resolved
Provide copy of valid EPIRB registration (expired 5/28/2025). Vessel restricted to lakes, bays and sounds route within 3 miles of shore.
Action required: 705 - Other - as specified
Resolved 13 August 2025
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2025
Resolved
Provide copy of valid FCC Bridge to Bridge Certificate.
47 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed, found in binder after visit exp 8/2026
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 6 June 2025
Resolved
Provide working Emergency Lighting in Engine Room behind stairway access. When MI tested, no light came on.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 6 June 2025
Resolved
Filter housing for the potable water tank is leaking. Replace/repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 June 2025
Resolved
Address gaskets for port and starboard weathertight doors in the wheelhouse. Duct tape being used as a draft stop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 June 2025
Resolved
Complete and log Drills (Man Overboard, Fire and Abandon Ship). Drills have not been logged in over a year.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2025
Resolved
Provide gauge for fire pump, or way to test pressure. (50 PSI, with flow rate of 80GPM)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 June 2025
Resolved
Replace Engine Room Bilge Float Switch (for high water alarm), currently sending a faulty signal to the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2025
Resolved 13 August 2025
Resolution: completed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2025
Resolved
[name withheld] hydrostatic release unit. This was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2025
Resolution: marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2024
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Installed bilge system was unable to be tested due to air in the system. Prove proper operation of installed bilge system.
46 CFR 143.275
Action required: 10 - Deficiency Rectified
Resolved 21 May 2024
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 May 2024
Resolved
Emergency Lighting must be provided for all internal crew working and living areas. Current E-lighting was either inoperable or too dim to see by. Repair/replace with working emergency lighting.
46 CFR 143.410 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 6 June 2024
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 May 2024
Resolved
Each Crewmember must receive instruction required annually (Fire Drill, MOB Drill, Abandon Ship Drill). Last recorded drills were conducted 5/9/2023. Complete drills and log prior to commercial work being completed.
46 CFR 140.420 (c-d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2024
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2024
Resolved
A COI for a towing vessel is valid for 5 years from the date of issue. Vessels COI expired 5/9/2024. Vessel may not operate commercially as a towing vessel until a COI inspection has been scheduled and completed by a USCG Marine Inspector. 46 CFR 136.215
Action required: 705 - Other - as specified
Resolved 21 May 2024
Resolution: completed COI
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 5 February 2024
Resolved
While conducting Drydock Extension, MI found excessive water in the forepeak bilge, as well as liquid in the E/R Bilge (due to coolant leak that has been fixed). Remove liquid from forepeak and E/R bilges prior to any towing vessel operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2023
Resolved
Bilge high level alarms located on the bridge are not marked to identify locations.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 28 July 2023
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 July 2023
Resolved
Liferaft was incorrectly installed. Painter line was not connected to the weak leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2021
Resolved
Liferaft servicing overdue. Vessel restricted to limited geo are within Mohawk's facilities in New London/Groton, CT.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2021
Resolution: Serviced
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 16 June 2021
Resolved
4 charges required, vessel has one.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 19 August 2021
Resolution: Rec'd receipt of purchase
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 June 2021
Resolved
Provide FCC Bridge to Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 6 August 2021
Resolution: provided
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 16 June 2021
Resolved
Ascertain source of carbon monoxide within main cabin superstructure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2021
Resolution: O/O found that nitrogen also sets of CO alarms, and the source is batteries. O/O mitigating this by ventilation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 May 2019
Resolved
Emergency lighting must be provided for all working and living areas. Emergency lighting was unplugged and did not light up once plugged in. Provide working emergency lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 23 May 2019
Resolution: provided
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 9 May 2019
Resolved
Must be installed or portable bilge pump for emergency dewatering. Prove proper operation of FWD bilge suction and stbd engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 23 May 2019
Resolution: operated in presence of MI
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 May 2019
Resolved
Provide line throwing appliance with aux line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 23 May 2019
Resolution: provided
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018
Resolved
Vsl is broadcasting broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 25 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.