Records from 2004 to 2021. Most recent: inspection, 30 September 2021.
Documentation record
Registered dimensions (L × B × D)26.0 ft × 9.5 ft × 4.8 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC BOAT COMPANY · BROOKLIN, ME, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCONANICUT ISLAND, RI
Trade endorsementsRecreational
DocumentationValid · issued 7 April 2026 · expires 30 April 2028
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
30 September 2021
Type not recorded
No type recorded · Station Castle Hill · USCG Northeast District (CGD-NE) · Activity 7324124
8 November 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6581529
24 October 2018
Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6566649
20 July 2017
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6213737
11 April 2017
Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6133984
3 November 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6034080
27 September 2016
Deficiency Check · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6011440
1 December 2015
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5773337
12 July 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4376369
28 October 2010
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3868515
20 September 2010
Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3853394
21 July 2009
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3541498
19 November 2008
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3365941
15 September 2008
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3325492
13 November 2007
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3095426
25 September 2006
Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2786373
4 October 2005
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2506891
20 October 2004
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2223097
8 September 2004
Initial Certification · Simplified Stability Test · Plan Review "T" Boat
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2190442
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 3 November 2016
Resolved
Vessel is missing one of two B-II type fire extinguishers required onboard per COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2016
Resolved 3 November 2016
Resolution: Vessel operator was able to get proper number of B-II type fire extiguishers onboard before CG inspectors departed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 November 2016
Resolved
Vessel needs to have a current 2016 Light List onboard.
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 10 January 2017
Construction/Loadline › Hull › Side Shell
Issued 27 September 2016
Resolved
Provide reapairs to damaged areas of port transom.
Action required: 705 - Other - as specified
Due 7 October 2016
Resolved 14 October 2016
Resolution: Port transom was repaired to original construction.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 October 2010
Resolved
Show proof of proper operation of depth sounder.
Condition: Improper Installation
Due 14 November 2010
Resolved 2 November 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 October 2010
Resolved
Provide course on port side passenger embarkation point.
Condition: Improper Installation
Due 14 November 2010
Resolved 2 November 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 28 October 2010
Resolved
Replace #3 fire extinguisher.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2010
Resolved 31 October 2010
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 October 2010
Resolved
Provide proof of passenger counting procedures.
Due 14 November 2010
Resolved 17 November 2010
Resolution: O/O submitted verification of passenger count via email.
Engineering › Bilge Water Management System › Pump
Issued 28 October 2010
Resolved
Provide visual indicator for automatic bilge pump in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2010
Resolved 2 November 2010
Engineering › Bilge Water Management System › Pump
Issued 28 October 2010
Resolved
Replace engine compartment bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2010
Resolved 2 November 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 October 2010
Resolved
Prove proper operation of aft bilge high level alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2010
Resolved 31 October 2010
Engineering › Steering Gear System › Bracket/Clamp
Issued 30 July 2009
Resolved
Rudder post missing keyway for emergency steering tiller. Prove proper operation of the emergency steering tiller.
Condition: Unknown
Due 30 August 2009
Resolved 19 August 2009
Resolution: Keyway and emergency steering tiller provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 July 2009
Resolved
Uncorrected copy of the 2005 edition Light List onboard. O/O to provide most current or updated Light List.
Condition: Improper/Lack of Maintenance
Due 30 August 2009
Resolved 19 August 2009
Resolution: Light list provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 November 2007
Resolved
Renew wasted grab line on vessels life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 28 November 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 8 November 2007
Resolved
Properly repair bilge high water alarm in the aft bilge. Have crew member make rounds every 15 minutes vessels is underway with passengers onboard until this item is cleared by the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 November 2007
Resolved 28 November 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 20 October 2004
Resolved
Vessel route limited to nmt 1000 ft. from land until satisfactory completion of FCC Safety radio inspection.
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 2 November 2004
Resolution: Item cleared.
Construction/Loadline › Structures › Ventilators
Issued 20 October 2004
Resolved
Re-route F/O vent outside of hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 26 October 2004
Resolution: Item cleared.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 September 2004
Resolved
Provide 14 adult and 2 child size life preservers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Lifesaving › Lifebuoys › Not on Board
Issued 8 September 2004
Resolved
Provide and mount a ring life buoy and 60 feet of line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 September 2004
Resolved
[name withheld] stowage locations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Fire Fighting › Fire Bucket › Availability
Issued 8 September 2004
Resolved
Provide 3 fire buckets with lanyards and mark as "FIRE BUCKETS".
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 8 September 2004
Resolved
Provide and mount 3 portable fire extinguishers. One size B-1 and two size B-2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Lifesaving › Hand Flares › Not on Board
Issued 8 September 2004
Resolved
Provide three day time flares and three night time flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2004
Resolved
Provide a first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 September 2004
Resolved
Provide and post emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 September 2004
Resolved
Provide a bridge and training log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 September 2004
Resolved
Conduct crew drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2004