FELICIANA

FELICIANA is a 1956 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in July 2017, along with 23 deficiencies, 1 operational control, 1 with no removal date recorded and 3 casualty investigations between 2004 and 2011.

Records from 2004 to 2017. Most recent: inspection, 20 July 2017.

Built
1956
Last inspected
20 July 2017
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 July 2017
Operational controls 1 with no removal date recorded
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3967
Flag
UNITED STATES
Maury page id
psix-71580

Documentation record

Registered dimensions (L × B × D)97.3 ft × 36.0 ft × 7.8 ft
Registered tonnagegross 281 / net 191
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCALCASIEU SHIPBUILDING CO · CARLYSS, LA, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it281 - Regulatory (Subpart C or D), Gross Ton
191 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

20 July 2017 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6206316
14 June 2017 Drydock Extension
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6176098
15 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6088943
24 January 2017 COI Inspection · MTSA Verification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6068320
21 December 2016 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6060640
1 December 2016 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6051029
28 June 2016 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5894385
4 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5868717
21 April 2016 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5859704
13 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5853087
1 April 2016 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5845200

Deficiency record · 23

Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 January 2017 Resolved
All nav lights inoperable. Make repairs demonstrate proper operation to CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Installed new relay on nav panel. Tested all nav lights in primary and secondary fillaments with satisfactory results.
Communications › Public Address System › Announcing Station
Issued 24 January 2017 Resolved
PA system inoperable. Make repairs, demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2017
Resolved 15 February 2017
Resolution: Tested PA system with sat results.
Fire Fighting › Fire Pumps › Pressure
Issued 24 January 2017 Resolved
Port fire pump not self priming. Demonstrate proper operation to CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Tested port fire pump with sat results.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2017 Resolved
Engine room port and stbd soft patches, leaking into engine room. make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Sealled port and stbd soft patches.
Construction/Loadline › Penetrations › Gasket
Issued 24 January 2017 Resolved
Multiple penetration to engine room WTB and overhead not sealed. properly seal all TWBK and overhead in ingine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: All penetrations to engine room properly sealed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 January 2017 Resolved
Battery chargers in engine room and CO2 room missing splash shields. install splash/drip shield.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Splash shields installed on all battery chargers.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 21 December 2016 Resolved
IBA was moved to the ACADIA
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Properly installed approved and inspected 100 pers IBA.
Communications › Internal Communications System › Sound-powered Telephone
Issued 21 December 2016 Resolved
Light for sound powered phone removed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2017
Resolution: Tested SPP SAT.
Documentation › Certificates/Documents › High-Speed Craft Safety Certificate
Issued 1 December 2016 Resolved
FCC Station License exp. Renew document NLT 09DEC16.
Due 9 December 2016
Resolved 9 December 2016
Resolution: Provided renewed FCC Cert.
Communications › Alarms/Indicators › General Alarm
Issued 1 December 2016 Resolved
General alarm in engine room not marked approprietly. Mark general alarm.
Due 16 December 2016
Resolved 9 December 2016
Resolution: Marked light for general alarm in engine room.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 28 June 2016 Resolved
Domestic Regulatory Tonnage Certificate, not international
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 2 August 2016
Resolution: It was discovered that the vessel possessed a valid tonnage certificate.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 June 2016 Resolved
Emergency lighting for Rescue Boat Platform did not energize upon power failure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: LIght properly operating
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 28 June 2016 Resolved
Gasket on man-hole (Port Side of Tank) worn away due to improper material selection having a bad reaction with petroleum.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 2 August 2016
Resolution: Gasket was replaced and a proper seal was established.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 28 June 2016 Resolved
Starboard Shaft in Shaft Alley not adequately guarded. Deck plates had broken off that typically cover the space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 2 August 2016
Resolution: Shaft guard was bolted above rotating machinery to ensure proper protection from hazard.
Engineering › Bilge Water Management System › Strainer
Issued 28 June 2016 Resolved
Strainer in Shaft Alley is wasted. Strainer must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 2 August 2016
Resolution: Strainer was replaced.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 28 June 2016 Resolved
IBA not on board in accordance with COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: IBA placed onboard prior to going back into service
Lifesaving › Rescue Boat › Construction
Issued 28 June 2016 Resolved
Rescue Boat not on board.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: Rescue boat and new motor back onboard vessel
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 21 April 2016 Resolved
100 PERSON IBA was lost overboard due to vessel stricking mooring apron. Rafts have been recovered and are tied up. Replacement IBA enroute.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2016
Resolution: New IBA installed
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 April 2016 Resolved
Vessel missing maintenance records for life saving equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Records initiated onboard
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2016 Resolved
No documented training on board. Unable to verify drills were conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Drill log being initiated
Navigation › Piloting/Steering › Gyro Compass
Issued 5 April 2016 Resolved
Vessel missing light on compass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Light repaired
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 5 April 2016 Resolved
Vessel must provide verification of working overspeed on SSDG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 4 May 2016
Resolution: Third party report received.
Engineering › Compressed Air System (control) › Valve
Issued 5 April 2016 Resolved
Vessel must provide proper function of air pressure relief valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 1 December 2016
Resolution: Tested relief valve

Casualty record · 3

15 June 2004Routine · role: Involved in a Marine Investigation (non-casualty) · activity 2123943
17 December 2009Routine · role: Involved in a Marine Casualty · activity 3654568
23 December 2011Routine · role: Involved in a Marine Casualty · activity 4217527
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.