Records from 2004 to 2017. Most recent: inspection, 20 July 2017.
Documentation record
Registered dimensions (L × B × D)97.3 ft × 36.0 ft × 7.8 ft
Registered tonnagegross 281 / net 191
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCALCASIEU SHIPBUILDING CO · CARLYSS, LA, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it281 - Regulatory (Subpart C or D), Gross Ton
191 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
20 July 2017
MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6206316
14 June 2017
Drydock Extension
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6176098
15 February 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6088943
24 January 2017
COI Inspection · MTSA Verification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6068320
21 December 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6060640
1 December 2016
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6051029
28 June 2016
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5894385
4 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5868717
21 April 2016
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5859704
13 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5853087
1 April 2016
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5845200
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 January 2017
Resolved
All nav lights inoperable. Make repairs demonstrate proper operation to CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Installed new relay on nav panel. Tested all nav lights in primary and secondary fillaments with satisfactory results.
Communications › Public Address System › Announcing Station
Issued 24 January 2017
Resolved
PA system inoperable. Make repairs, demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2017
Resolved 15 February 2017
Resolution: Tested PA system with sat results.
Fire Fighting › Fire Pumps › Pressure
Issued 24 January 2017
Resolved
Port fire pump not self priming. Demonstrate proper operation to CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Tested port fire pump with sat results.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2017
Resolved
Engine room port and stbd soft patches, leaking into engine room. make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Sealled port and stbd soft patches.
Construction/Loadline › Penetrations › Gasket
Issued 24 January 2017
Resolved
Multiple penetration to engine room WTB and overhead not sealed. properly seal all TWBK and overhead in ingine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: All penetrations to engine room properly sealed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 January 2017
Resolved
Battery chargers in engine room and CO2 room missing splash shields. install splash/drip shield.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Splash shields installed on all battery chargers.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 21 December 2016
Resolved
IBA was moved to the ACADIA
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Properly installed approved and inspected 100 pers IBA.
Communications › Internal Communications System › Sound-powered Telephone
Issued 21 December 2016
Resolved
Light for sound powered phone removed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2017
Resolution: Tested SPP SAT.
Documentation › Certificates/Documents › High-Speed Craft Safety Certificate
Issued 1 December 2016
Resolved
FCC Station License exp. Renew document NLT 09DEC16.
Due 9 December 2016
Resolved 9 December 2016
Resolution: Provided renewed FCC Cert.
Communications › Alarms/Indicators › General Alarm
Issued 1 December 2016
Resolved
General alarm in engine room not marked approprietly. Mark general alarm.
Due 16 December 2016
Resolved 9 December 2016
Resolution: Marked light for general alarm in engine room.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 28 June 2016
Resolved
Domestic Regulatory Tonnage Certificate, not international
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 2 August 2016
Resolution: It was discovered that the vessel possessed a valid tonnage certificate.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 June 2016
Resolved
Emergency lighting for Rescue Boat Platform did not energize upon power failure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: LIght properly operating
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 28 June 2016
Resolved
Gasket on man-hole (Port Side of Tank) worn away due to improper material selection having a bad reaction with petroleum.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 2 August 2016
Resolution: Gasket was replaced and a proper seal was established.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 28 June 2016
Resolved
Starboard Shaft in Shaft Alley not adequately guarded. Deck plates had broken off that typically cover the space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 2 August 2016
Resolution: Shaft guard was bolted above rotating machinery to ensure proper protection from hazard.
Engineering › Bilge Water Management System › Strainer
Issued 28 June 2016
Resolved
Strainer in Shaft Alley is wasted. Strainer must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 2 August 2016
Resolution: Strainer was replaced.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 28 June 2016
Resolved
IBA not on board in accordance with COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: IBA placed onboard prior to going back into service
Lifesaving › Rescue Boat › Construction
Issued 28 June 2016
Resolved
Rescue Boat not on board.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2016
Resolved 1 December 2016
Resolution: Rescue boat and new motor back onboard vessel
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 21 April 2016
Resolved
100 PERSON IBA was lost overboard due to vessel stricking mooring apron. Rafts have been recovered and are tied up. Replacement IBA enroute.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2016
Resolution: New IBA installed
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 April 2016
Resolved
Vessel missing maintenance records for life saving equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Records initiated onboard
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2016
Resolved
No documented training on board. Unable to verify drills were conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Drill log being initiated
Navigation › Piloting/Steering › Gyro Compass
Issued 5 April 2016
Resolved
Vessel missing light on compass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 4 May 2016
Resolution: Light repaired
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 5 April 2016
Resolved
Vessel must provide verification of working overspeed on SSDG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 4 May 2016
Resolution: Third party report received.
Engineering › Compressed Air System (control) › Valve
Issued 5 April 2016
Resolved
Vessel must provide proper function of air pressure relief valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 1 December 2016
Resolution: Tested relief valve