Inspection history · 13
25 September 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8225492
25 September 2024
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7977432
28 August 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7991613
28 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7751346
12 October 2022
Annual Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7576356
6 July 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7235389
14 October 2020
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7077473
25 June 2019
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6725795
20 November 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581517
10 July 2018
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6458873
21 August 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6244126
5 December 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6053131
6 June 2016
COI Inspection · Simplified Stability Test · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5899300
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 September 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high-water. The high-water alarm visual indicators were not operating as designed for each assigned space. Repair the visual high water level alarms at the operating station to the satisfaction of the attending marine inspector. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 30 September 2025
Resolution: Lights restored to operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. The bilge pump in the steering space was not UL listed. Replace the pump with a UL listed to the satisfaction of the attending marine inspector. 46 CFR 182.520 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 30 September 2025
Resolution: The pump was replaced with an approved pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 September 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be of at least 18.3 meters (60 feet) in length. Replace with 60ft line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 2 October 2023
Resolution: Corrected, see attached photograph.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2023
Resolved
The Designated employer representative (DER) is an employee authorized by the employer to take immediate action(s) to remove employees from safety-sensitive duties, or cause employees to be removed from these covered duties, and to make required decisions in testing and evaluation processes. The DER also receives test results and other communications for the employer, consistent with the requirements of this part. [name withheld] was listed as the vessel's DER. Designate another person which is not a member of the vessel's crew as the DER or allow for third party to cordinate DER's testing.
49 CFR 40.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 11 October 2023
Resolution: DER was removed from the consortium. Proof was emailed to MI and uploaded.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2022
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. During underway operations an approximately 3 inch fracture was found on the rudder packing flange requiring replacement.
46 CFR 176.814
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: Rudder flange replaced and tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 July 2021
Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Vessel had no rudder stops. Install rudder stops to the satisfaction of attending Marine Inspector.
46 CFR 182.610(e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 31 July 2021
Resolution: Vessel rep installed effective rudder stops.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2021
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel had no markings indicating that no passengers are allowed on the fly bridge. Place durable markings indicating no passengers are allowed on the fly bridge.
46 CFR 185.602(g)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 7 July 2021
Resolution: Vessel rep marked no passengers allowed on fly bridge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 July 2021
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] were not clearly labeled. Label fire buckets.
46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 July 2021
Resolved 7 July 2021
Resolution: Operator labeled fire buckets in presence of marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in servicable condition must be repaired or replaced. Line on vessel's life ring buoy is worn. Replace life ring buoy.
46CFR176.808(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2020
Resolution: Provided picture of replaced life ring buoy in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 October 2020
Resolved
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: inspection and operation of through hull fittings and sea valves. Cap off two non-used sea valves in engine compartment as discussed.
46CFR176.802(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2020
Resolution: Provided photographs of the capped-off sea valves.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 October 2020
Resolved
Independent fuel tanks must be designed and constructed as described in this paragraph. Reseal fuel tank return connection.
46CFR182.440(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: Sent pictures of fuel tank return connection, cleaned and resealed with West system and 404 bonding compound.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2019
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light housing unit was cracked and light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 22 July 2019
Resolution: Verified proper operation of port running light. Photograph attached in documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Fuses in electrical systems must be of the cartridge type only. Fuses for the bilge water alarm are blade type fuses. Provide proper installation of cartridge type fuses in the electrical system onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 22 July 2019
Resolution: Verified proper installation of cartridge type fuses in electrical system. Photograph attached in documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2018
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have at the operating station, an audible alarm that sounds upon discharge. Repair/renew audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 31 July 2018
Resolution: Vessel installed new indicator and proved proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with an attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Vessel has two buckets onboard. Provide additional fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 11 July 2018
Resolution: Vessel provided 03 properly labled fire buckets with lanyards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2018
Resolved
A visual indicator must be provided at the operating station to indicate when an automatic bilge pump is operating. Install indicators for automatic bilge pumps at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 10 August 2018
Resolution: Vessel repaired existing indicators and proved proper operation.
Engineering › Bilge Water Management System › Pump
Issued 21 August 2017
Resolved
Prove proper operation of bilge pump high water visual/audible alarm at operating station for pump located in forward space in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 23 August 2017
Resolution: Proper operation of bilge audible/visual alarm proven.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 August 2017
Resolved
Correct vessel call sign on NOAA EPIRB registration to align with actual call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 23 August 2017
Resolution: Owner provided proof of submission of NOAA EPIRB application to correct vessel call sign.
Operations/Management › Vessel Activity › Underway
Issued 21 August 2017
Resolved
Vessel was oberved operating with passengers for hire carrying its shark cage onboard, a violation of the terms and operational limits of its COI per 46 CFR 176.110.
Due 21 August 2017
Resolved 21 August 2017
Lifesaving › Hand Flares › Not on Board
Issued 6 June 2016
Resolved
Provide 6 red hand flares.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 5 December 2016
Resolution: Proper amount of red hand flares provided onboard.
Engineering › Bilge Water Management System › Interface Detector
Issued 6 June 2016
Resolved
Provide a properly operating bilge high level alarm in the aft steering compartment.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 5 December 2016
Resolution: Alarm functioning.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 June 2016
Resolved
Provide a floatlight for ring bouy.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 5 December 2016
Resolution: Floatlight provided.