Records from 1997 to 2020. Most recent: inspection, 30 April 2020.
Documentation record
Registered dimensions (L × B × D)63.5 ft × 18.1 ft × 6.0 ft
Registered tonnagegross 66 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ST. LOUIS, MO, UNITED STATES · built 1955
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBEARDSTOWN, IL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
30 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6946182
10 July 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4650385
23 November 2010
Administration · DAPI Audit
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3898924
17 November 2010
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3893251
22 May 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2937519
28 February 2007
Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2880840
14 November 2006
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2820865
9 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2563230
29 December 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2557669
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997010
14 December 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 435794
15 December 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 423866
12 November 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 409981
9 October 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 408911
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Permanently install (electrically hard wire) the rose boxes, electric bilge pumps.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Ensure all overhead electrical wires are supported with metal supports every 24".
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Replace the Romex house wire in the stern of the engineroom with an approved wire (U/L Marine or NEC wet and damp location).
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Cover exposed electrical wires in the overhead of the stbd head.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Lifesaving › Lifebuoys › Stowage
Issued 28 February 2007
Resolved
Ensure life rings are immediately available and not bungeed to the vessel.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Remove abandoned wire located in the forward, engineroom, adjacent to the general alarm bell.
Condition: Placed in Improper Service
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 February 2007
Resolved
Blank off open breakers in the forward, engineroom electrical box, stbd side.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 February 2007
Resolved
Repair the main deck, forward, exposed electrical outlet box cover.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 February 2007
Resolved
Cover exposed galley heater.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 28 February 2007
Resolved
Blank off the abandoned port and stbd side sewage line where it exits the vessel.
Condition: Improper/Lack of Maintenance
Due 15 April 2007
Resolved 21 May 2007
Fire Fighting › Nozzles › Approval
Issued 28 February 2007
Resolved
Ensure the portable fire pump has an adjustable nozzle installed.
Condition: Placed in Improper Service
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 February 2007
Resolved
Properly install the battery for the port main engine.
Condition: Placed in Improper Service
Due 15 April 2007
Resolved 21 May 2007
Engineering › Steering Gear System › Linkage
Issued 28 February 2007
Resolved
Ensure the port rudder arm linkage is not chafing the air compressor piping system and properly guard to compressor exposed pulley.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Fire Fighting
Issued 14 December 1999
Resolved
SERVICE DRY CHEMICAL FIRE EXTINGUISHER.
Condition: Unknown
Due 14 January 2000
Resolved 11 May 2000
Lifesaving
Issued 14 December 1999
Resolved
REPLACE ON E TYPE I LIFEJACKET THAT WAS FOUND TO BE IN POOR CONDITION.
Condition: Unknown
Due 14 December 1999
Resolved 15 December 1999
Documentation
Issued 15 December 1998
Resolved
ORIGINAL COD NOT ONBOARD.
Condition: Unknown
Due 15 January 1999
Resolved 5 May 1999
Lifesaving
Issued 15 December 1998
Resolved
MACHINERY GUARD MISSING FROM MOVING PARTS ON STEERING PUMP
Condition: Unknown
Due 15 January 1999
Resolved 5 May 1999
Lifesaving
Issued 15 December 1998
Resolved
OLD OVERBOARD DISCHARGE PORTS NEED TO BE CLOSED OFF OR CAPPED.
Condition: Unknown
Due 15 January 1999
Resolved 5 May 1999
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 October 1997
Resolved
NO LOCAL NOTICE OT MARINERS ON BOARD
Condition: Unknown
Due 9 November 1997
Resolved 14 November 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 October 1997
Resolved
NO MARPOL PLACARD ON BOARD.
Condition: Unknown
Due 9 November 1997
Resolved 14 November 2006