Records from 2016 to 2026. Most recent: inspection, 9 March 2026.
Documentation record
Registered dimensions (L × B × D)149.0 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 92 / net 52
ITC dimensions (L × B × D)149.0 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 498 / net 163
BuilderBOLLINGER SHIPYARD LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
498 - Convention (Subpart B), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
163 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
9 March 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277611
27 February 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085910
10 December 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8042213
19 November 2024
Drydock Exam · Cargo Tank Internal · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037303
17 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7850294
2 February 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7630843
5 December 2022
Cargo Tank Internal · Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7604186
10 February 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393794
4 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7134925
17 June 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6981041
15 November 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6856515
8 November 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6851998
23 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6691811
26 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6632864
22 January 2019
MTSA Verification · Ballast Water Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6613156
18 December 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599567
2 January 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331477
10 October 2017
Examination of Repairs · Deficiency Check · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6284401
8 November 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6034072
18 October 2016
Deficiency Check · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6024597
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 January 2024
Resolved
Emergency lighting must have enough capacity for 6 hours of operation.
3 emergency lights were extinguished in the engine room and passageway.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
Resolution: Batteries were replaced and lights tested.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 January 2024
Resolved
Standby vessels must have a fire monitor with minimum flow rate of 500 GPM.
Fire monitor has missing bolts and wrong bolts in some areas. repair and prove proper operation prior to standby service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2024
Resolved 28 January 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 February 2023
Resolved
Each Class 1 watertight door must have an open/close indicator on the bridge; indicator not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2023
Resolved 2 February 2023
Resolution: Indicator switch replaced and tested.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 February 2023
Resolved
Cargo hoses must be tested annually; methanol transfer hose not tested. Prior to transfer ops. Methanol
Action required: 705 - Other - as specified
Due 2 February 2023
Resolved 2 February 2023
Resolution: New Methanol hose purchased. Test report provided Hydro test 300 PSI 02FEB2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2022
Resolved
Vls less tahn 100 GT must have navigational lighting IAW navigation rules. Anchor light did not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Anchor light replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2022
Resolved
Vsl less than 100 GT must have emergency lighting along escape route from accommodations and machinery spaces. Multiple emergency lights were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Emergency lights replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 February 2022
Resolved
Each survival craft must be illuminated by emergency lighting. Emergency light on top of pilothouse did not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Emergency light replaced.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 10 February 2022
Resolved
Each vsl equippped with independent steering must have means of communication. Sound powered phone in engine room is faint and can not be heard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 22 February 2022
Resolution: Sound powered phone replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 February 2022
Resolved
During each inspection the proper condition of lifefloats will be checked. Lifefloat on stbd side has cracking and missing pieces of outer shell.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 17 February 2022
Resolution: Lifefloat replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2022
Resolved
Visible and audible alarms must be installed in the pilothouse for high bilge level. Bilge for engine room was in alarm due to high level in bilge. Have bilges pumped to a reg facility.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Bilges pumped down.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2022
Resolved
Electrical equipment must be installed to minimize hazards. Stbd generator control/gage panel was loose from its mounting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Panel reattached.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019
Resolved
Vessel did not have life float painter line & float-free link installed correctly on both lifefloats. Vessel must ensure that the painter be stowed in such a way that it runs out freely when the lifefloat floats away from the sinking OSV.
46CFR133.105(4)(iii)(D)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 November 2019
Resolved
Both doors to the engine room and the starboard deck hatch required adjustment and the forward engine room WTD gasket was worn. The vessel shall ensure all hatches and openings in the hull are made watertight by the use of gaskets.
46CFR131.520
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2019
Resolved
The liquid mud transfer pumps emergency shutdowns were not operable. Also, the port mud pump was seized and not operable. The vessel must provide a means to stop the flow and it must be operable from the cargo deck, cargo control room, or the usual operating station of the person in charge of the transfer operation.
33CFR155.780
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 27 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2019
Resolved
The following non-metallic hoses do not meet CG approved standard; 04 hoses on both MDE reduction gears and the starboard MDE L/O filter line. The starboard generator fuel filter return line was frayed, and cracked. Vessel must ensure the hoses and fittings meet SAE J1942 & SAE J1475 respectively.
46 CFR 56.60-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 17 December 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 November 2019
Resolved
Vessel emergency lighting in galley area was not operable. Vessel must ensure it has individual battery powered lighting that automatically actuates upon loss of normal power.
46CFR129.440
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 19 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2019
Resolved
Vessel had power strips with multiple electronics plugged into a wall outlet, and extension cords running
along racks in several crew berthing areas. Vessel must ensure electrical equipment on board must protect the crew from electrical fires, caused by or originating in electrical equipment and shock.
46CFR129.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 20 November 2019
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 2 January 2018
Resolved
Repair/replace wasted anchor chain, swivel, and attached wire rope to satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Anchor chain and wiring was replaced and installed to satisfaction of Marine Inspector.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 10 October 2017
Resolved
Pressure cylinder on extinguisher wasted and pressure lost. Carriage of methanol prohibited until a serviceable extinguisher is place onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2017
Resolved 20 October 2017
Resolution: Unit sent out for servicing. Cylinder replaced, unit placed back on vessel.
Lifesaving › Lifefloat › Serviceable
Issued 8 November 2016
Resolved
REPAIR OR REPLACE CRACKED LIFE FLOAT AND RE-INSTAL PROPERLY
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2016
Resolution: REPLACED AND PROPERLY INSTALED LIFE FLOAT.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 8 November 2016
Resolved
REPAIR LUBE OIL LEAK ON PORT MAIN TURBO.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2016
Resolution: SAT REPAIR
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 November 2016
Resolved
CONDUCT AN ANNUAL REVIEW OF NON TANK VESSEL RESPONSE PLANN, AND UPDATE AS NECESSARY. LAST RECORDED CHANGES IN VRP IS 2009
Condition: Improper/Lack of Maintenance
Due 22 November 2016
Resolved 9 November 2016
Resolution: CONDUCTED REVIEW AND UPDATED PLAN.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 November 2016
Resolved
PROVIDE PROOF OF OSRO CONTRACT WITH OSRO LISTED IN VRP
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2016
Resolved 9 November 2016
Resolution: PROVIDED CONTRACT