← All vessels
CAPT RUDY
Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named CAPT RUDY
CAPT RUDY is a 2004 offshore supply vessel. The Coast Guard has recorded 29 inspections since 2004, most recently in March 2026, along with 46 deficiencies and 1 operational control.
Records from 2004 to 2026. Most recent: inspection, 9 March 2026.
- Built
- 2004
- Last inspected
- 9 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 46 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1162736
9337420 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC2099
718381
Flag
UNITED STATES
366987890
Maury page id
psix-718381
Inspections, by type
…with no type recorded1
Years with a record
18 calendar years (2004–2026)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)149.0 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 92 / net 52
ITC dimensions (L × B × D)149.0 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 498 / net 163
BuilderBOLLINGER SHIPYARD LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
498 - Convention (Subpart B), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
163 - Convention (Subpart B), Net Ton
498 - Convention (Subpart B), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
163 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC2099MMSI 366987890 · active · compulsorily equipped · granted 12 October 2024, expires 3 November 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 29
9 March 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277611
27 February 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085910
10 December 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8042213
19 November 2024
Drydock Exam · Cargo Tank Internal · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037303
17 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7850294
2 February 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7630843
5 December 2022
Cargo Tank Internal · Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7604186
10 February 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393794
4 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7134925
17 June 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6981041
15 November 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6856515
8 November 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6851998
23 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6691811
26 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6632864
22 January 2019
MTSA Verification · Ballast Water Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6613156
18 December 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599567
2 January 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331477
10 October 2017
Examination of Repairs · Deficiency Check · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6284401
8 November 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6034072
18 October 2016
Deficiency Check · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6024597
13 November 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5762859
18 January 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3926791
5 January 2009
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3389186
17 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3326010
20 November 2007
Internal Structural Exam · Hull Examination · Cargo Tank Internal · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3101432
31 January 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2864532
18 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2568569
23 November 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2246911
10 June 2004
Initial Certification · MTSA Verification · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2094468
Deficiency record · 46
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 January 2024
Resolved
Emergency lighting must have enough capacity for 6 hours of operation.
3 emergency lights were extinguished in the engine room and passageway.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 January 2024
Resolved
Standby vessels must have a fire monitor with minimum flow rate of 500 GPM.
Fire monitor has missing bolts and wrong bolts in some areas. repair and prove proper operation prior to standby service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 February 2023
Resolved
Each Class 1 watertight door must have an open/close indicator on the bridge; indicator not working.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 February 2023
Resolved
Cargo hoses must be tested annually; methanol transfer hose not tested. Prior to transfer ops. Methanol
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2022
Resolved
Vls less tahn 100 GT must have navigational lighting IAW navigation rules. Anchor light did not work.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2022
Resolved
Vsl less than 100 GT must have emergency lighting along escape route from accommodations and machinery spaces. Multiple emergency lights were inoperable.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 February 2022
Resolved
Each survival craft must be illuminated by emergency lighting. Emergency light on top of pilothouse did not work.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 10 February 2022
Resolved
Each vsl equippped with independent steering must have means of communication. Sound powered phone in engine room is faint and can not be heard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 February 2022
Resolved
During each inspection the proper condition of lifefloats will be checked. Lifefloat on stbd side has cracking and missing pieces of outer shell.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2022
Resolved
Visible and audible alarms must be installed in the pilothouse for high bilge level. Bilge for engine room was in alarm due to high level in bilge. Have bilges pumped to a reg facility.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2022
Resolved
Electrical equipment must be installed to minimize hazards. Stbd generator control/gage panel was loose from its mounting.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019
Resolved
Vessel did not have life float painter line & float-free link installed correctly on both lifefloats. Vessel must ensure that the painter be stowed in such a way that it runs out freely when the lifefloat floats away from the sinking OSV.
46CFR133.105(4)(iii)(D)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 November 2019
Resolved
Both doors to the engine room and the starboard deck hatch required adjustment and the forward engine room WTD gasket was worn. The vessel shall ensure all hatches and openings in the hull are made watertight by the use of gaskets.
46CFR131.520
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2019
Resolved
The liquid mud transfer pumps emergency shutdowns were not operable. Also, the port mud pump was seized and not operable. The vessel must provide a means to stop the flow and it must be operable from the cargo deck, cargo control room, or the usual operating station of the person in charge of the transfer operation.
33CFR155.780
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2019
Resolved
The following non-metallic hoses do not meet CG approved standard; 04 hoses on both MDE reduction gears and the starboard MDE L/O filter line. The starboard generator fuel filter return line was frayed, and cracked. Vessel must ensure the hoses and fittings meet SAE J1942 & SAE J1475 respectively.
46 CFR 56.60-25
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 November 2019
Resolved
Vessel emergency lighting in galley area was not operable. Vessel must ensure it has individual battery powered lighting that automatically actuates upon loss of normal power.
46CFR129.440
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2019
Resolved
Vessel had power strips with multiple electronics plugged into a wall outlet, and extension cords running
along racks in several crew berthing areas. Vessel must ensure electrical equipment on board must protect the crew from electrical fires, caused by or originating in electrical equipment and shock.
46CFR129.200
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 2 January 2018
Resolved
Repair/replace wasted anchor chain, swivel, and attached wire rope to satisfaction of Marine Inspector.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 10 October 2017
Resolved
Pressure cylinder on extinguisher wasted and pressure lost. Carriage of methanol prohibited until a serviceable extinguisher is place onboard.
Lifesaving › Lifefloat › Serviceable
Issued 8 November 2016
Resolved
REPAIR OR REPLACE CRACKED LIFE FLOAT AND RE-INSTAL PROPERLY
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 8 November 2016
Resolved
REPAIR LUBE OIL LEAK ON PORT MAIN TURBO.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 November 2016
Resolved
CONDUCT AN ANNUAL REVIEW OF NON TANK VESSEL RESPONSE PLANN, AND UPDATE AS NECESSARY. LAST RECORDED CHANGES IN VRP IS 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 November 2016
Resolved
PROVIDE PROOF OF OSRO CONTRACT WITH OSRO LISTED IN VRP
Communications › Radio Communications › EPIRB
Issued 17 November 2015
Resolved
EPIRB Battery expired January of 2015. Correct prior to sailing.
Construction/Loadline › Structures › Scuttle
Issued 17 November 2015
Resolved
Engine room escape hatch not operable form inside the space due to missing handle.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 November 2015
Resolved
Alcohol test strips expired.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 17 November 2015
Resolved
Pressure/vacuum valves on methanol tanks not labeled with settings and handle cap frozen. Vessel not to load methanol until cleared.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 November 2015
Resolved
Vessel response plan not available on board.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 17 November 2015
Resolved
Transfer procedures do not include methanol in products to be transferred and MSDS is not available on board.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 November 2015
Resolved
Panelboard directories do not include rated loads.
Fire Fighting › Fire Pumps › Pressure
Issued 17 November 2015
Resolved
Fire pump pressure gauge not in working order.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 17 November 2015
Resolved
Fuel oil transfer pump pressure gauge not in working order.
Electrical › Electric Supply System (service) › Cable
Issued 17 November 2015
Resolved
Dead end wire forward of starboard generator to be identified and capped/removed.
Construction/Loadline › Structures › Ventilators
Issued 17 November 2015
Resolved
Engine room ventilation shares ventilation duct below the main deck with the bow thrudter compartment, making the ventilation duct not continuously watertight to the main deck. Deficiency extended 1 year to facilitate plan review/retrofit per SECNOLA CID.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 13 November 2015
Resolved
Lifesaving equipment maintenance logs/checklists not available.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 18 January 2011
Resolved
Provide copy of transfer procedures for vessel as per 33 CFR 155.730
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 January 2011
Resolved
Provide alcohol test strips for each crew member prior to sail
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 January 2011
Resolved
Properly log draft marks of vessel prior to departing port in voyage plans.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 18 January 2011
Resolved
Properly secure fuel leak port MDE.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 18 January 2011
Resolved
Provide chafing gear for turbo lines of main engines.
Lifesaving › Line-Throwing Appliances › Lines
Issued 31 January 2007
Resolved
Provide auxiliary line.
Communications › Radio Communications › Emergency Source of Power
Issued 31 January 2007
Resolved
Provide second source of electricity for comms system IAW 56 CFR 129.310
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 January 2007
Resolved
Demonstrate proper operation of emergency light illuminating main switchboard
Communications › Radio Communications › EPIRB
Issued 31 January 2007
Resolved
Mark expiration date on newly installed hydrostatic release for EPIRB
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 January 2006
Resolved
Provide additional fire protection for portable tanks prior to carriage.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2006
Resolved
Provide equip for stanby service.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.