Records from 2004 to 2019. Most recent: operational control imposed, 1 April 2019.
Inspection history · 35
1 April 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6653840
8 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6638677
8 March 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6638696
20 February 2019
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6629108
23 January 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6342045
23 December 2017
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327449
21 September 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6271610
23 December 2016
Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6059610
25 November 2015
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5772062
19 February 2012
ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4241668
7 January 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3661865
6 January 2010
MARPOL Annex I Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3659231
3 July 2008
ISPS II Exam · MARPOL Annex V Examination · COC-TVE Annual · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3248410
2 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3247816
25 June 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3247826
13 November 2007
ISPS III Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3096339
14 May 2007
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2928036
12 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2928719
23 March 2007
Type not recorded
No type recorded · Maritime Safety & Security Team Cape Cod (91110) · Activity 2893434
7 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2673110
6 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2672152
31 May 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2666219
3 April 2006
COC-TVE Renew
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2615450
5 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2579879
18 August 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2466927
16 August 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2465103
14 August 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2466834
29 July 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2444033
17 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2396488
15 December 2004
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2259395
27 November 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2248831
19 September 2004
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2199298
18 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2200462
17 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2198606
10 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2192837
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 8 March 2019
No resolution recorded
All ships of 300 gross tonnage and upwards and passenger ships irrespective of size shall... be fitted with: an echo-sounding device, or other electronic means, to measure and display the available depth of water. Vessel's echo depth sounder is out of service.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 December 2017
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. STBD side lifeboat engine wouldnt start due to a faulty ignition switch. 10c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 December 2017
Resolved 23 December 2017
Resolution: Vessel repaired in the spot
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 December 2017
Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Two patches were found on the STBD side S/W cooling line. 50 a,c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Vessel submitted satisfactory Class report attesting to the repairs.
Deck/Cargo › Ballast › Pumps
Issued 21 September 2017
Resolved
74SOLAS(2014 cons.) CH I Reg 11(b)- After any survey of the ship under regulations7,8,9 or 10 has been completed no change shall be made in the structural arrangments, machinery, equipment and other items covered by the survey without sanction of the administration. The ballast system is not operational due to failure of the ballast pump. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2017
Resolution: Sector LA/LB recieved class report attesting to the repair of the ballast water system.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 December 2016
Resolved
0799: Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Vessel has a washer and dryer installed in a duct space on "B" deck which is not reflected on the vessel's fire control plan. The vessel also converted an electrical cable trunk space into an electrician's workshop which is not reflected on the vessel's fire control plan.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 December 2016
Resolved 28 December 2016
Resolution: Vessel provided Class report, stating applicable changes were made to fire control plan.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 14 May 2007
Resolved
The duct trunk was converted to a dryer room on C deck. The fire control plans does not reflect this alteration. Have class inspect the space and amend ship's plans and space to satisfaction of Class. SOLAS 2004 (cons ed) II-2/15.2.4
Action required: 15 - Rectify deficiencies by next port
Due 14 June 2007
Resolved 30 August 2007
Resolution: dryer was removed from above space to satisfaction of class.
Operations/Management › Pollution › Control of Garbage
Issued 14 May 2007
Resolved
The Garbage Management Plan is not ship specific. The plan does not address procedures for disposing of expired medicine/hospital waste/batteries/light bulbs. The GMP does not give detailed information on proper segregation of garbage types. Furthermore, the GMP does not specify that plastic is allowed to be incinerated and the incinerator was found to be full of mixed garbage to include plastic.
Action required: 15 - Rectify deficiencies by next port
Due 14 June 2007
Resolved 30 August 2007
Resolution: garbage management plan has been revised to include information on the above deficiencies.