Records from 2002 to 2009. Most recent: inspection, 28 April 2009.
Documentation record
Registered dimensions (L × B × D)128.0 ft × 38.0 ft × 7.5 ft
Registered tonnagegross 337 / net 337
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1956
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it337 - Regulatory (Subpart C or D), Gross Ton
337 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
28 April 2009
Attraction Vessel Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461975
8 December 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3376297
2 May 2008
COI Inspection · Deficiency Check · Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3201562
4 June 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2950927
21 May 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2936053
19 April 2007
COI Inspection · Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911119
5 October 2006
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2794497
28 October 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1700706
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 28 April 2009
Resolved
Provide a towing bridle, rigged and ready for immediate use in the event of an emergency.
Due 28 May 2009
Resolved 22 May 2009
Resolution: After review of MSM II.B.4.cc, a towing bridle, readily available for emergency use is not required and the cg-835 has been withdrawn.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2009
Resolved
Remove all dead end and bare wiring from a weather station no longer in use as discussed with the vessel representative. Wiring is located on the outboard side of the storage container.
Due 28 May 2009
Resolved 22 May 2009
Resolution: In accordance with the statement from the vessel representative, all bare end wiring was properly secured into a junction box.
Documentation › Markings/Placards › Warning Signs
Issued 28 April 2009
Resolved
Post an appropriate sign prohibiting passengers from accessing the office space.
Due 28 May 2009
Resolved 22 May 2009
Resolution: In accordance with statement from the vessel representative, proper signage was placed on the door leading to a none passenger access area.
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 28 April 2009
Resolved
Provide Material Safety Data Sheets (MSDS) for all hazardous material stowed on the vessel. Several 5 gallon buckets full of plant food/plant nutrients were stored in the storage shed and believed to be hazardous. All containers with hazardous materials are to be properly labeled.
Due 28 May 2009
Resolved 22 May 2009
Resolution: In accordance with the statement from the vessel representative, MSDS''s for all hazardous materials were provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 2 May 2008
Resolved
Provide for servicing for all B-II portable fire extingushers (05 total). Send copy of serving report to USCG when corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 7 May 2008
Resolution: Recieved faxed service report.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 4 June 2007
Resolved
Repair the generator exhaust leak prior to operating the generator with passengers onboard.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Engineering › Fuel Oil Service System › Hose
Issued 2 May 2007
Resolved
Install approved hose on the generator prior to using with passengers onboard.
Action required: 705 - Other - as specified
Resolved 4 June 2007
Engineering › Fuel Oil Service System › Hose
Issued 2 May 2007
Resolved
Install approved fuel hose on the forced air heater and prove proper operation prior to using with passengers onboard.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 May 2007
Resolved
Label the liferings with the vessel name (HUGHES 728).
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 4 June 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 2 May 2007
Resolved
Submit a proposal to replace the extension cords with a permanent installation.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 4 June 2007
Documentation › Markings/Placards › Warning Signs
Issued 2 May 2007
Resolved
Label the restricted areas (employees only).
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 4 June 2007