Records from 1993 to 2018. Most recent: inspection, 1 October 2018.
Inspection history · 16
1 October 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6554832
28 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5805106
25 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3308862
11 March 2008
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3166920
1 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2593782
20 January 2006
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2570147
12 January 2005
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2268807
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961050
5 September 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1603769
24 April 2001
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471427
25 February 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 104328
8 August 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 15805
8 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 162124
30 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 669180
23 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 28502
21 September 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 135525
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 11 March 2008
Resolved
Coast Guard Local Notice to Mariners required on board IAW 33 CFR 164.72(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 March 2008
Resolved
Illuminated magnetic compass required IAW 33CFR 164.72(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 11 March 2008
Resolution: Magnetic compass now illuminated.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 11 March 2008
Resolved
Echo depth sounding device required IAW 33 CFR 164.72(a0(50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 11 March 2008
Resolved
Pre-sail check list for Jan 2008 required IAW 33 CFR 164.78(b) and 33 CFR 164.80(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 March 2008
Resolved
Amber (upper) tow light not working IAW 33 USC 2023a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 11 March 2008
Resolution: Amber towing light now working properly
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 March 2008
Resolved
PFD lights expired on all Type 1 PFD's and submersion suits IAW 46 CFR 25.25-13
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 11 March 2008
Resolved
Provide proof fire detection system working properly and zones properly labeled in wheelhouse and main panel IAW 46 CFR 27.203
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 March 2008
Resolved
Proper labeling required for Remote Fuel Oil Shut Offs at shut off point IAW 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 11 March 2008
Resolved
Guards over light fixtures in machinery space need to be replaced (cracked and broken) IAW Good Marine Practice
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 11 March 2008
Resolved
Cover required on electrical boxes in steering room on pump IAW Good Marine Practice
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 March 2008
Resolved
Clean up wire and stabilize converter in wheelhouse under instrument panel IAW Good Marine Practice
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Engineering › Fuel Oil Service System › Gauge
Issued 11 March 2008
Resolved
Fuel oil sight glass (made from plastic) should be labeled "Close while underway," in machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Documentation › Markings/Placards › Oil Discharge Placard
Issued 11 March 2008
Resolved
Oil pollution discharge warning placard required on board IAW 33 CFR 15.450
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Communications › Radio Communications › EPIRB
Issued 11 March 2008
Resolved
EPIRB required on board IAW 46 CFR 25.26-20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel inactive since 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 January 2006
Resolved
Need lighted magnetic compass or swing meter as required under 33 CFR 164.72(a)(4)
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2006
Resolved 28 February 2006
Fire Fighting
Issued 24 April 2001
Resolved
RECHARGE FIRE EXTINGUISHER IN WHEEL HOUSE.
Condition: Unknown
Due 24 April 2001
Resolved 26 April 2001
Electrical
Issued 24 April 2001
Resolved
REPLACE PLASTIC CABLE TIES WITH METAL BRACKETS ON OVERHEAD ENGINE ROOM WIRING.
Condition: Unknown
Due 24 April 2001
Resolved 26 April 2001