MAURY USCG vessel records Sign in
← All vessels

BENNY N-T

BENNY N-T is a 1956 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1990, most recently in February 2020, along with 69 deficiencies — 4 with no resolution recorded — and 1 casualty investigation in 2012.

Records from 1990 to 2020. Most recent: inspection, 4 February 2020.

Built
1956
Last inspected
4 February 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9921
Flag
UNITED STATES
367409210, 367510220 (licence lapsed)
Maury page id
psix-72096

Inspections, by type

…with no type recorded5
Years with a record 23 calendar years (1990–2020)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.4 ft × 17.1 ft × 6.3 ft
Registered tonnagegross 46 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEWART SEACRAFT INC · BERWICK, LA, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF9921MMSI 367510220 · expired · compulsorily equipped · granted 22 November 2011, cancelled 22 January 2022
WDE8756MMSI 367409210 · expired · compulsorily equipped · granted 12 May 2009, cancelled 13 July 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PORT UNION Tank Ship · MISLE 620873 · 15 May 2003 · activity 1804696

Inspection history · 36

4 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6902574
25 October 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6842174
25 March 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6648595
4 March 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6635906
6 December 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6319583
10 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6121863
23 November 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6046739
7 November 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6036780
4 November 2016 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6035079
5 October 2016 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6016898
13 October 2015 Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5741172
11 January 2010 Examination of Repairs · Drydock Exam · Annual Inspection · Damage Survey · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3662077
7 May 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3469416
5 May 2009 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3467700
17 September 2008 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3327991
17 September 2008 Damage Survey · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3328137
16 April 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3185513
20 February 2008 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3150380
16 February 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2293489
5 January 2005 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2269756
10 December 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1961685
15 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1804696
26 December 2002 Initial Certification · Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1705424
6 June 2002 Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1627047
20 September 2001 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074230
24 August 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464312
3 September 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361087
21 July 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433361
15 August 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425956
23 August 1996 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380635
1 September 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358893
15 August 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470094
4 August 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408992
14 August 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249327
28 August 1991 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937492
22 May 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899908

Deficiency record · 69

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 February 2020 No resolution recorded
A vessel must carry a First Aid Kit. The first aid kit on-board has expired aspirin, eyewash, and burn cream.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 February 2020 No resolution recorded
Any vessel of at least 5 net tons must have a Certificate of Documentation (COD) bearing a valid endorsement appropriate for the activity in which engaged.
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 4 February 2020 No resolution recorded
Rails must be provided near the periphery of all decks of a vessel accessible to passengers or crew. Port aft stanchion of Authorized Personnel area is cracked where stanchion meets the deck. Repair to the satisfaction of the Coast Guard. Additionally, renew starboard Authorized Personnel sign. Repair to the satisfaction of the Coast Guard.
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 February 2020 No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. There was excessive oil coatings in the bilges of the engine room and lazarette during the time of the inspection. Clean Engine Room and make ready for inspection.
Action required: 60 - Rectify deficiencies prior to movement
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2019 Resolved
Provide current and correct charts for area of operation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Captain has current and corrected charts for area of operation area onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 March 2019 Resolved
Provide updated 1st Aid Kit
Action required: 705 - Other - as specified
Due 7 April 2019
Resolved 4 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2019 Resolved
Properly terminate all electrical connections on board, remove dead end wires and wire nuts and clean up wiring in wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Electrical in the wheelhouse has been properly terminated and cleaned up. Dead wires have been removed and wire ends have wire nuts on them.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 4 March 2019 Resolved
Provide signage for passengers to not move beyond chains
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: "Authorized Personnel Only" signs have been added to the exterior of the cargo area.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2019 Resolved
Provide three 2.5 gallon fire buckets
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Three 2.5 gallon fire buckets are onboard.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 4 March 2019 Resolved
Repair cracked stbd window in wheelhouse
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: stbd window in wheelhouse has been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 March 2019 Resolved
Remove debris from compressor room bilges and make safe
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Debris has been removed from compressor room bilges.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 4 March 2019 Resolved
Remove unused compressor tank from compressor room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Unused compressor tank has been removed from the compressor room.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 March 2019 Resolved
Permanently mount new air compressor
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Air compressor has been mounted by means of metal bands.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 March 2019 Resolved
Provide ammeter for generator
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 4 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 4 March 2019 Resolved
Provide captive chains or other device (tether) for all free hatch covers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 14 March 2019
Resolution: Chain and shackel have been applied to all free hatch covers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2019 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Your vessel passed its reinspection window by one month and one day.
Action required: 705 - Other - as specified
Due 7 March 2019
Resolved 4 March 2019
Resolution: Endorsed the COI refer to enforcemnt.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 March 2019 Resolved
Prove port rudder trunk is leak free
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Re packed steering post. Sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 December 2017 Resolved
Valid COI was not present onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2019
Resolution: COI was reissued with the new endorsement no other action taken.
Electrical › Electric Generation Source (service) › Generator
Issued 10 April 2017 Resolved
Received notice vessel's generator and main engine failed while vsl loaded stores to another ship. Prove proper operation of generator and main engine prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2017
Resolved 12 April 2017
Resolution: Witnessed proper operation of generator and main engines. All sat. Conducted successful sea trials.
Construction/Loadline › Structures › Deck Plating
Issued 23 November 2016 Resolved
Remove existing doubler plates and crop and renew in-kind wasted deck areas on the forward main deck where the pilot-house/cabin and deck meet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2016
Resolved 13 December 2016
Resolution: renewed in-kind the wasted deck areas on the forward main deck where the pilot-house/cabin and deck meet.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 November 2016 Resolved
Vessel has removed required passanger saftey rail. Vessel must permanently reinstall aft passenger safety rail to the satisfaction of the Coast Guard Marine Inspector attending
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 17 November 2016
Resolution: Crew permanently affixed proper rails.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 May 2009 Resolved
Failure to make vessel available for annual inspection within 3 months before or after each anniversary date of issuance of the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2009
Resolution: Conducted annual exam.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 19 September 2008 Resolved
Until the Fixed Haylon System is recharged and reinstalled provide 1 B-V CO2 Extinguisher at the entrance to the machinery space.
Action required: 705 - Other - as specified
Due 20 October 2008
Resolved 19 September 2008
Resolution: Vessel has a B-V extinguisher on board.
Engineering › Bilge Water Management System › Not Operational
Issued 19 September 2008 Resolved
Prove proper operation of the Bilge alarm system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2008
Resolution: Bilge alarms repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 17 September 2008 Resolved
Recharge and prove proper operation of the fixed fire fighting system in the machinery space.
Action required: 705 - Other - as specified
Due 19 October 2008
Resolved 5 May 2009
Resolution: Fixed gas firefighting system has been installed and operatig properly
Engineering › Bilge Water Management System › Pump
Issued 16 April 2008 Resolved
Vessel required to permantly affix bilge system and piping also to install valves .
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 19 September 2008
Resolution: Item corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 April 2008 Resolved
Reinstall the hand rails on the aft deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2008
Resolved 5 May 2009
Resolution: Handrails installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 February 2008 Resolved
Provide a navigational chart of the operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 16 April 2008
Resolution: New Navigational charts provided
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 February 2008 Resolved
Provide a copy of the Tide Tables for the Houston Ship Chanel.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 16 April 2008
Resolution: tide tables provide
Documentation › Markings/Placards › Warning Signs
Issued 20 February 2008 Resolved
Stencil the Remote Fuel Shutdown location.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 16 April 2008
Resolution: Remote fuel shutdown stenciled
Lifesaving › Hand Flares › Not on Board
Issued 20 February 2008 Resolved
Provide 3 red hand flares and 3 orange day smokes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 16 April 2008
Resolution: day and night flares provided
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 20 February 2008 Resolved
Permanently affix the vessel documentation number to the hull.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: Hull 3 permentaly affixed to hull fwd bulk head.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 February 2008 Resolved
REplace the broken lighting fixture in the forward #2 compartment.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: Light fixture replced in # 2 compartment
Stability › Watertight Integrity › General
Issued 20 February 2008 Resolved
Replace the gasket on the watertight door art of the machinery space.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: Water tight gasket replaced in engine room
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 February 2008 Resolved
Provide 2 additional Type I PFD's.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: 2 pfd provided
Lifesaving › Lifebuoys › Stowage
Issued 20 February 2008 Resolved
Provide a clip on the line to the light of the Lifebuoy.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: clip on light of the lifebouy provided.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 February 2008 Resolved
Re-install the missing railing system for passengers around the aft deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2008
Resolved 16 April 2008
Resolution: Reissued this date.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 February 2008 Resolved
Repair the Starboard rudder packing glad.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2008
Resolved 16 May 2008
Resolution: rudder packing glad reinstalled.
Electrical › Electric Supply System (service) › Cable
Issued 20 February 2008 Resolved
Install a blank to cover the hole in the electrical panel located on the machinery space forwrd bulkhead.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 May 2008
Resolution: Cover installed in electrical panel.
Engineering › Steering Gear System › Bracket/Clamp
Issued 20 February 2008 Resolved
Replace pins on the port rudder post with an appropriate type.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: Pins replaced on port ruder post.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 February 2008 Resolved
Post the valid COI.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 16 April 2008
Resolution: Coi I posted .
Construction/Loadline › Hull › Hull Plating
Issued 19 February 2008 Resolved
Weld the two pin holes in the starboard Sideshell, aft corner and amidship, located three feet above the waterline.
Action required: 705 - Other - as specified
Due 19 March 2008
Resolved 23 April 2008
Resolution: Pin holes g/w and reapired satisfactory.
Fire Fighting › Fire Bucket › Quantity
Issued 19 February 2008 Resolved
Provide 3 2.5 gallon fire buckets with line and properly marked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2008
Resolved 16 May 2008
Resolution: three buckets and stenciled provided.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 January 2005 Resolved
Replace existing pressure vessel with ASME certified pressure vessel (air compressor system) prior to conducting cargo operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2005
Resolution: Pressure vessel certified under ASME VIII code.
Deck/Cargo › Towing › Chocks
Issued 5 January 2005 Resolved
Repair or replace aft bit.
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 16 February 2005
Resolution: Bit has been removed.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 January 2005 Resolved
Provide CPR certification for 50% of crew.
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 16 February 2005
Resolution: Certification provided
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2005 Resolved
Replace romex cable going to air compressor with marine grade wire IAW IEEE code.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2005
Resolution: Wire has been replaced with marine grade wiring
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 5 January 2005 Resolved
Remove electrical box and electrical wiring in cargo hold.
Due 6 February 2005
Resolved 16 February 2005
Resolution: Box has been removed
Engineering › Reduction Gearing/Clutches › Shaft
Issued 5 January 2005 Resolved
Replace missing bolts on both shaft flanges.
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 16 February 2005
Resolution: Replaced bolt on shaft
Engineering › Steering Gear System › Rudder
Issued 5 January 2005 Resolved
Repair rudder post packing gland and repack prior to resuming operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2005
Resolution: Gland repaired and repacked.
Engineering › Steering Gear System › Rudder
Issued 5 January 2005 Resolved
Install stbd rudder keeper nut prior to resuming operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2005
Resolution: Keeper nut has been installed on starboard rudder.
Engineering › Fuel Oil Service System › Filter
Issued 5 January 2005 Resolved
Repair fuel leak on generator fuel pressure switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2015
Resolution: Fuel leak on generator has been fixed
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 5 January 2005 Resolved
Secure air compressor pressure vessel.
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 16 February 2005
Resolution: Pressure vessel secured to deck and wall brackets
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 5 January 2005 Resolved
Replace missing bolt on belt guard on generator
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 16 February 2005
Resolution: Replaced bolt on belt guard
Engineering › Bilge Water Management System › Pump
Issued 5 January 2005 Resolved
Mount bilge alarm in cargo hold.
Due 6 February 2005
Resolved 16 February 2005
Resolution: Bilge alarm has been mounted
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2005 Resolved
Repair hole in deck on portside above engine compartment.
Due 6 February 2005
Resolved 16 February 2005
Resolution: Problem corrected
Electrical › Electric Supply System (service) › Cable
Issued 10 December 2003 Resolved
Secure all loose wiring under instrument dash.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Wires under dash have been secure
Lifesaving › Buoyant Apparatus › Lifeline
Issued 10 December 2003 Resolved
Install halyard clip on light leading to lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problem corrected
Construction/Loadline › Structures › Trunk
Issued 10 December 2003 Resolved
Secure all loose items in the aft compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problems corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 December 2003 Resolved
Secure batteries in battery storage box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Battery have been secured in battery box
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 December 2003 Resolved
Hard wire battery charger to the electrical system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Battery charger has been disconnected.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 December 2003 Resolved
Replace all household electrical face plates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Replaced electrical covers with weather tight covers
Engineering › Steering Gear System › Linkage
Issued 10 December 2003 Resolved
Install cotter pin on STBD steering shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problem has been corrected
Construction/Loadline › Penetrations › Weld
Issued 10 December 2003 Resolved
Make permanent repair to the hinge on the aft hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problem corrected
Electrical › Electric Supply System (service) › Cable
Issued 10 December 2003 Resolved
In AFT compartment secure all electrical wiring IWO runner.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Wires have been secured
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 10 December 2003 Resolved
Repair broken light fixture in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Fixture has been replaced
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 10 December 2003 Resolved
Repair machinery guard on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problem corrected
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 December 2003 Resolved
STBD fuel shutoff not operating freely due to damaged to the splash guard. Make permanent repair so valve can operate freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 16 February 2005
Resolution: Problem corrected
Construction/Loadline › Hull
Issued 13 November 2002 Resolved
Excessive pitting in area of the port prop shaft and STBD bow hull plating. Required visual inspection of the repair prior to painting the hull. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 3 December 2002
Resolution: Visual inspection of the repair (insert plate 3/8" X 4'' X 10'': 3/8" X 18" X 18"), all sat.

Casualty record · 1

5 April 2012Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4283469
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record