MAURY USCG vessel records Sign in
← All vessels

THEODOSIA

THEODOSIA is a 2004 tank ship. The Coast Guard has recorded 19 inspections since 2004, most recently in November 2008, along with 5 deficiencies and 7 operational controls.

Records from 2004 to 2008. Most recent: inspection, 8 November 2008.

Built
2004
Last inspected
8 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9275751 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
721050
Flag
MARSHALL ISLANDS
—
Maury page id
psix-721050

Inspections, by type

…with no type recorded11
Years with a record 5 calendar years (2004–2008)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42307 - Convention (Subpart B), Gross Ton
69999 - Dead Weight, Ton
83889 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

8 November 2008 MARPOL Annex I Examination · COC-TVE Renew · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3358434
13 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3266945
11 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3265054
20 January 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3133383
15 January 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3130575
16 December 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3114308
15 December 2007 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 3116263
2 July 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2980657
4 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2866877
15 October 2006 Ballast Water Examination · Deficiency Check · ISPS III Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2794645
26 July 2006 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2726160
1 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2558961
30 October 2005 Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2524776
25 September 2005 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2500516
30 August 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2479366
25 April 2005 Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2341970
19 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2224149
26 September 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2206392
21 September 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2200976

Deficiency record · 5

Navigation › Collision/Grounding Avoidance › Radar
Issued 20 January 2008 Resolved
Received notification that the 3 cm radar was malfunctioning. Repairs to the 3 cm radar must be completed by a certified technician.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2008
Resolution: Received tech report stating that the repairs to the radar have been completed.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 16 December 2007 Resolved
Section 2.3.2, in the SMPEP references Appendix 7, for keeping a list of local contact numbers for ports visited. This section has not been kept current with the ports visited. The Master needs to update this section.
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 15 January 2008
Resolution: Received a report from the Administration stating that this item has been corrected to their satisfaction, concur with the report received.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 December 2007 Resolved
Section 2.1.1 in the VRP references section 9, which list the oil spill response organization (OSRO). In section 9, it list Clean Bay as the OSRO. However, the ship's field manual list MSRC. Section 9, of the VRP needs to be updated by the Company / Master.
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 15 January 2008
Resolution: Received a report from the Administration stating that this item has been corrected to their satisfaction, concur with the report received.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 16 December 2007 Resolved
In the Ballast Water Management Plan section 7, needs to be filled in for safe tank entry requirements. In addition the ballast Water Handling Log Form being used must be incorporated into the plan and section 9, which identified sediment removal needs to be addressed. The Chief Mate is logging sediment removal, and disposal but the details are not listed in the plan as it should be.
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 15 January 2008
Resolution: Received a report from the Administration stating that this item has been corrected to their satisfaction, concur with the report received.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 15 October 2006 Resolved
Vapor Collection System Certification Letter could not be provided during COC Renewal Exam. Certification letter to be provided prior to conducting Cargo Operations in U.S. Port. Correct to Satisfaction of Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2006
Resolution: Received copy of Vapor Control Approval Letter from ABS Class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.