Records in 2016. Most recent: operational control imposed, 14 February 2016.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
2 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 February 2016
Resolved
0750- The minimum fire integrity of bulkheads and decks shall be prescribed in Tables 44.1 (column 11, A-60). The A-60 boundaries protecting the emergency escape and multiple exits and entries in the engine room are degraded and not satisfactory protecting the intended spaces. 74 SOLAS (01 con) II-2/44.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2016
Resolved 16 February 2016
Resolution: Vessel procured and installed ATP approved materials to effect successful repairs to the A-60 protective fire boundary to the satisfaction of the attending Classification Society inspectors NKK and attending Coast Guard Port State Control Examiners.
Engineering › Sea-water System (primary cooling) › Pump
Issued 13 February 2016
Resolved
1499- Special consideration shall be given to the malfunctioning of; the sources of water pressure; an air compressor and receiver for starting or control purposes. There is only one operable means of providing salt water pressure for cooling vessel generators and start air compressors to meet full operational requirements. 74 SOLAS (04 cons) II-1/26.6/.9
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2016
Resolved 16 February 2016
Resolution: Vsl engineers succesfully made satisfactory temp repairs ensuring redundancy to the No1 S.W. feed pump to the vsl generators and start air compressors. Repairs were made to satisfaction of attending NKK Class Surveyor and USCG Port State Control Examiners
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 February 2016
Resolved
2515- The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of relevant rules.. The company shall ensure that corrective action is taken. Upon notification of multiple non-conformity reports pertaining to essential equipment, the company failed to take prompt action to rectify the reported inoperable equipment.74SOLAS(14)IX/3.1, ISM 10.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2016
Resolved 16 February 2016
Resolution: The ISM Company, VSL Class NKK, and MALTA Flag all concurred on findings of ISM non-conformities pertaining to requisition of damaged equipement. SMC audit conducted on 16FEB16 by NKK. ISM Company audit scheduled 03MAY16. All verfied by PSC Examiners
Construction/Loadline › Markings › Load Line Mark
Issued 13 February 2016
No resolution recorded
1220- The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background. They shall also be permanently marked on the sides of the ships. The deck line is a non-contrasting color to the hull and the load line in compliance with the ILL certificate is not permanently affixed. Load Line 66' Reg. 8
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2016 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 February 2016
No resolution recorded
1230- Satisfactory means shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. Significant corrosion and damage to guardrails was found on the freeboard deck. Load Line 66' Reg. 25.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-electric) › Pump, High Pressure (fuel injection)
Issued 13 February 2016
No resolution recorded
0820- Oil fuel lines shall be suitably protected to avoid oil leakages onto hot surfaces, into machinery air intakes, or other sources of ignition. Vessel's electric diesel generator fuel pump is leaking onto engine parts and onto deck. 74 SOLAS (01 cons) II-2/15.2.11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Filter
Issued 13 February 2016
No resolution recorded
0820- In a ship in which oil fuel is being used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and the person on board. Vessel has fuel oil leaks on the boiler fuel pump, fuel valve within the purifier room and multiple fuel oil purifier gauges. 74 SOLAS (01 cons) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-electric) › Turbocharger
Issued 13 February 2016
No resolution recorded
0820- The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Vessel's main propulsion engine has exhaust leak on the back of the turbo. 74 SOLAS (04 cons) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 13 February 2016
No resolution recorded
1440- The arrangement of bilge and ballast pumping systems shall be such as to prevent the possibility of water passing from the sea and from water ballast tanks into the cargo and machinery spaces. Vessel's jacket water cooler and both ballast pumps are leaking sea water directly into the machinery space. 74 SOLAS (04 con) II-1/21.1.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded
Fire Fighting › Fire Hoses › Condition
Issued 13 February 2016
No resolution recorded
0720- Fire hoses shall be of non-perishable material approved by the administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Multiple hoses have duct tape and other improper repairs made to them throughout the engine room. 74 SOLAS (01 cons) II-2/4.7.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 13 February 2016
No resolution recorded
1430- After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without sanction by the administration. The No. 1 generator prime mover does not have a starter motor installed, rendering it inoperative. 74SOLAS (14 cons)I/11(b)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 February 2016
No resolution recorded
1299- Satisfactory means for safe passage as required by regulation 25-1 shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and other spaces used in the essential operation of the ship. Multiple ladder steps within the machinery spaces were either deformed or cracked. ICLL 66' (88) reg. 25(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016 — due date passed with no resolution recorded