Records from 2016 to 2025. Most recent: inspection, 3 August 2025.
Inspection history · 29
3 August 2025
ACP COI Oversight · Re-Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8191921
4 February 2025
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8074793
31 January 2025
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8077465
2 January 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8056962
10 April 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7897844
6 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7893664
28 February 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7872256
16 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850175
11 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850174
10 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850170
7 December 2023
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7836312
18 November 2023
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7830079
9 June 2023
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7714356
28 December 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7614384
18 November 2022
ACP Annual Oversight · Underwater Inspection in lieu of Drydock · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7629436
25 September 2021
ACP Annual Oversight · In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7312359
19 August 2021
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7291622
21 July 2021
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7271124
6 January 2021
Re-Inspection · In-Service Inspection · ACP COI Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7117918
20 December 2019
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6877299
29 October 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6844932
26 August 2019
Deficiency Check · ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6795721
18 October 2018
Annual Inspection · Ballast Water Examination · ACP Periodic Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6563940
23 October 2017
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6347436
12 October 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6295105
14 April 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6124223
12 September 2016
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5976753
13 April 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5910869
27 January 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5804650
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2019
Resolved
FIREFIGHTING SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER. FIREMAIN PIPING FOR FIRE PLUG 72 HAS A PIN HOLE LEAK. SOLAS (04) II-2, REG 14. 2.1.2.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: ABS Accpeted the deficiency on 17 OCT 2019. Report Number S3734426.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 26 September 2019
Resolved
ONE OR MORE TOTALLY ENCLOSED LIFEBOATS COMPLYING WITH THE REQUIREMENTS OF SECTION 4.6 OF THE LSA CODE SHALL BE CARRIED. 25 FOOD RATIONS ARE NO LONGER SERVICEABLE. SOLAS (04) III, REG 31. 1.1.1
Action required: 10 - Deficiency Rectified
Resolved 27 September 2019
Resolution: NEW RATIONS WERE OUTFITTED ON THE LIFEBOATS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2019
Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING:
1. PORT AND STBD ENG ROOM DOORS TO WEATHER DECK DO NOT SELF CLOSE.
2. PORT ENG ROOM DOOR TO WEATHER DECK DOES NOT LATCH CLOSED.
3. PORT ENG ROOM LOWER DOORS TO CENTER P-WAY ARE NOT GASTIGHT.
SOLAS (04) II-2, REG 9 4.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: ABS Accpeted the deficiency on 17 OCT 2019. Report Number S3734426.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 August 2019
Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent over-stressing the falls or davits. Found aft limit switch lever corroded on lifeboat #3. Replace corroded limit switch lever within 30 days. Corrosion observed on the exterior housing for all lifeboat davit limit switches. Failure of the limit switch housing's watertight boundary may permit moisture ingress and short circuit. Inspector and crew were unable to verify the condition of the circuit inside of the housing due to the limit switch installation at the end of the davit and over the water. Verify condition of lifeboat davit limit switch circuits within 30 days and replace per manufacturer instructions if necessary. Deficiency may be cleared by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 August 2019
Resolution: Lifeboat #3 aft limit switch replaced in kind. All other limit switch housing covers removed and verified to be water tight by the crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2019
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Found corroded and damaged wire supports for electrical cables located near the aft davit of lifeboat #2. Electrical cables are no longer supported properly. Support electrical cables within 30 days and renew electrical supports in kind. Deficiency may be cleared by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 September 2019
Resolution: Verified cable run brackets were replaced.