A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
3 August 2025
ACP COI Oversight · Re-Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8191921
4 February 2025
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8074793
31 January 2025
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8077465
2 January 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8056962
10 April 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7897844
6 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7893664
28 February 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7872256
16 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850175
11 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850174
10 January 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7850170
7 December 2023
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7836312
18 November 2023
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7830079
9 June 2023
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7714356
28 December 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7614384
18 November 2022
ACP Annual Oversight · Underwater Inspection in lieu of Drydock · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7629436
25 September 2021
ACP Annual Oversight · In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7312359
19 August 2021
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7291622
21 July 2021
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7271124
6 January 2021
Re-Inspection · In-Service Inspection · ACP COI Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7117918
20 December 2019
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6877299
29 October 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6844932
26 August 2019
Deficiency Check · ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6795721
18 October 2018
Annual Inspection · Ballast Water Examination · ACP Periodic Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6563940
23 October 2017
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6347436
12 October 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6295105
14 April 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6124223
12 September 2016
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5976753
13 April 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5910869
27 January 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5804650
13 October 2015
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5741811
14 August 2015
Administrative Inspection · ACP COI Oversight
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5216228
6 August 2015
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5208242
20 December 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4214707
4 August 2011
ACP Annual Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4105316
24 March 2010
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3703030
28 January 2010
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3671849
21 December 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3917136
6 October 2008
MTSA Verification · Underwater Inspection in lieu of Drydock · ACP Periodic Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3338234
23 July 2007
MTSA Verification · ACP Annual Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3006231
21 February 2007
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2880245
30 January 2007
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2864036
23 October 2006
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2804801
7 July 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2820062
29 June 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2742164
30 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2479551
7 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2418494
1 July 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2439199
1 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2406403
1 June 2003
Hull Examination · Initial Certification
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2309956
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2019
Resolved
FIREFIGHTING SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER. FIREMAIN PIPING FOR FIRE PLUG 72 HAS A PIN HOLE LEAK. SOLAS (04) II-2, REG 14. 2.1.2.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: ABS Accpeted the deficiency on 17 OCT 2019. Report Number S3734426.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 26 September 2019
Resolved
ONE OR MORE TOTALLY ENCLOSED LIFEBOATS COMPLYING WITH THE REQUIREMENTS OF SECTION 4.6 OF THE LSA CODE SHALL BE CARRIED. 25 FOOD RATIONS ARE NO LONGER SERVICEABLE. SOLAS (04) III, REG 31. 1.1.1
Action required: 10 - Deficiency Rectified
Resolved 27 September 2019
Resolution: NEW RATIONS WERE OUTFITTED ON THE LIFEBOATS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2019
Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING:
1. PORT AND STBD ENG ROOM DOORS TO WEATHER DECK DO NOT SELF CLOSE.
2. PORT ENG ROOM DOOR TO WEATHER DECK DOES NOT LATCH CLOSED.
3. PORT ENG ROOM LOWER DOORS TO CENTER P-WAY ARE NOT GASTIGHT.
SOLAS (04) II-2, REG 9 4.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: ABS Accpeted the deficiency on 17 OCT 2019. Report Number S3734426.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 August 2019
Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent over-stressing the falls or davits. Found aft limit switch lever corroded on lifeboat #3. Replace corroded limit switch lever within 30 days. Corrosion observed on the exterior housing for all lifeboat davit limit switches. Failure of the limit switch housing's watertight boundary may permit moisture ingress and short circuit. Inspector and crew were unable to verify the condition of the circuit inside of the housing due to the limit switch installation at the end of the davit and over the water. Verify condition of lifeboat davit limit switch circuits within 30 days and replace per manufacturer instructions if necessary. Deficiency may be cleared by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 August 2019
Resolution: Lifeboat #3 aft limit switch replaced in kind. All other limit switch housing covers removed and verified to be water tight by the crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2019
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Found corroded and damaged wire supports for electrical cables located near the aft davit of lifeboat #2. Electrical cables are no longer supported properly. Support electrical cables within 30 days and renew electrical supports in kind. Deficiency may be cleared by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 26 September 2019
Resolution: Verified cable run brackets were replaced.
Engineering › Diesel Engine (propulsion-electric) › Air-flex Clutch
Issued 23 July 2007
Resolved
Prove proper operation of the #4 Propulsion thruster to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 August 2007
Resolved 20 August 2007
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 30 January 2007
Resolved
Cabin door identification placards to not match Fire Control Plan on several decks
Condition: Unknown
Due 30 March 2007
Resolved 30 March 2007
Resolution: Cleared
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 January 2007
Resolved
Replace inoperative door to Hzmat Locker (1-22-01)
Condition: Damaged By Earlier Event
Due 30 March 2007
Resolved 30 March 2007
Resolution: Corrected
Lifesaving › Lifebuoys › Immediately Available
Issued 30 January 2007
Resolved
Lifebuoys provided with self-activating smoke signals are not capable of quick release for the navigational bridge. Not in compliance with SOLAS 74/78-rEG. 7.1.3 or Regulatory Compliance Matrix designed for vessel
Condition: Improper Installation
Due 30 March 2007
Resolved 30 March 2007
Resolution: ABS issued documentation that they considered current configuration met intent of SOLAS as it was consistant with MODU regulations. As vessel safety plan was approved by ABS under the ACP and the port issuing initial COI, requirement is being rescinded.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 January 2007
Resolved
Most of the A0 Fire Screen Doors in stairtowers do not properly close iaw SOLAS 74/78-Reg. 9.2.4.1
Condition: Design Flaw
Due 30 March 2007
Resolved 30 March 2007
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2007
Resolved
Remove extension cords from electgrical strip in Store Room within Gym. Provide adequate electrical outlets for workspace.
Condition: Improper Installation
Due 30 March 2007
Resolved 30 March 2007
Resolution: Corrected
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 30 January 2007
Resolved
Replace starboard lifeline on No. 1 lifeboat. Worn
Condition: Unknown
Due 30 March 2007
Resolved 30 March 2007
Resolution: Corrected
Fire Fighting › Means of Escape › Doorways
Issued 30 January 2007
Resolved
Repair damaged door handle assembly for door leading out of gym.
Condition: Improper/Lack of Maintenance
Due 30 March 2007
Resolved 30 March 2007
Resolution: Corrected
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 23 October 2006
Resolved
Complete installation of Oil Drum Flam Storage Locker.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 20 August 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 23 October 2006
Resolved
Complete repairs and adjustments of fire doors throughout vessel.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 20 August 2007