Records from 2004 to 2025. Most recent: inspection, 6 June 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
6 June 2025
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8153675
13 March 2025
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090118
10 January 2025
Appeal
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8060874
16 August 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7982566
11 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7848265
13 July 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7745180
11 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739883
12 January 2022
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7379668
3 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088738
18 September 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6814650
13 September 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6810869
6 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6592825
26 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6329104
15 September 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6001244
1 September 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5989848
10 October 2014
Internal Structural Exam · Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5002123
19 July 2012
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4383643
26 August 2011
COI Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4127475
16 December 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3911057
10 November 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3374263
30 May 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3222166
28 November 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3105682
18 August 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752285
27 September 2004
Initial Construction-Excluding Oversight · MTSA Verification · Inclining Experiment · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2206612
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 March 2025
Resolved
All marine engineering machinery shall be installed according to this sub-chapter. Port main engine had diesel fuel leakage originating at pressure gauge on top of main engine that needs repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2025
Resolved 25 March 2025
Resolution: Gauge was removed and hole was covered. Verified leak stopped.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 March 2025
Resolved
Suitable guards must be installed on each dangerous rotating piece of machinery. STBD engine guard was partially missing around rotating fly wheel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 25 March 2025
Resolution: Guard was properly installed to cover the moving machinery.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 March 2025
Resolved
Illustrations and instructions in English and any other appropriate language, as determined by the OCMI, must be conspicuously displayed at each muster station and in spaces where offshore workers are carried, to inform offshore workers of the method of donning lifejackets
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2025
Resolved 25 March 2025
Resolution: Proper instructions were posted to reflect donning of life jackets onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 January 2024
Resolved
A class 1 door must be able to withstand a head of water.
Watertight door starboard side engine room would not close properly and the gasket did not fit properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Repaired to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 July 2023
Resolved
Each vsl must meet requirements in subchaper S for subdivision and stability. Watertight door frame between port/stbd eng. rooms has cracked welds in teh corners, light shows through.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2023
Resolution: Cracks repaired, dye pen test sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 January 2022
Resolved
Overhead above starboard engine exhaust had a wasted visible hole. Vessel is required to maintain structural
integrity. Wasted portions must be cropped and renewed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Corrective actions verified.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 January 2022
Resolved
Found a broken guard rail on the port side of the pilot house deck. Railing is required and must be in working order. Weld must be completed to secure the railing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Corrective actions verified.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 January 2022
Resolved
Multiple lights throughout the ship are inoperable. This includes both emergency escape lighting and normal operating lights. All light fixtures will be reinspected by an attending marine inspector. Lights and their fittings must be in working order.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2022
Resolved 26 April 2022
Resolution: Lights were verified to be operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 January 2022
Resolved
The J-Bar holding the disembarkation line had
significant corrosion. This must be fully operable for
the safety of the crew. Vessel must remove rust and
renew as necessary and demonstrate operation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2022
Resolution: Corrective actions verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 12 January 2022
Resolved
No international tonnage certificate was on board. An
international tonnage certificate is required for the
vessel. ITC must be made available for the Marine
Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Corrective actions verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2022
Resolved
Flexible pipe seal on the hydraulic piping system were sunken in. Pipes must not be compromised in any way. Vessel must show fully operable hydraulic pipes.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Corrective actions verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 January 2022
Resolved
Turbo charge was exposed and capable of reaching temperatures in excess of 150 degrees Fahrenheit. Equipment reaching temperatures in excess of 150 degrees Fahrenheit must be insulated to protect crew or workers from burns. This must be covered and shown to be in working order to the attending inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2022
Resolution: Insulation was installed around the turbo charger.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 January 2022
Resolved
There was an extra pressure gauge on the starboard fire station that was both not required and not working. Either the gauge must work, or must be removed and capped.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Corrective actions verified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 November 2020
Resolved
The watertight door that separates the two engine room requires adjusting in order for the door indicator to reflect the open/closed position of the door. Vessel's pilothouse must contain a visual indicator showing whether the door is open or closed.
46 CFR 174.210(c)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2020
Resolution: Adjusted the watertight door to allow the indicator to reflect the door position.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 November 2020
Resolved
Audible alarm was not operable when testing the high-bilge level. Visible and audible alarm must be installed at the pilothouse to indicate the high bilge-level.
46 CFR 130.460(a)(4)
Action required: 10 - Deficiency Rectified
Resolved 3 November 2020
Resolution: Electrician was requested and troubleshooted the high bildge level alarm system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2020
Resolved
Fire pump gauge on the port side was not operable to identify pressure when fire pump/hose was activated. Vessel must be capable of delivering a single stream of water through the hose and nozzle of at least 50 psi.
46 CFR 132.120 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2020
Resolved 3 November 2020
Resolution: Replaced gauge.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 December 2017
Resolved
Vessel found with an inoperable radar. Demonstrate proper operation of marine radar prior to operating.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 December 2017
Resolved
Vessel found with inoperable gauges on port and starboard main engines. Replace gauges to satisfaction of attending CGMI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 December 2017
Resolved
Watertight doors in E/R found not watergight, incapable of being closed. Adjust or repair doors to make watertight prior to operating.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 December 2017
Resolved
Engine for starboard generator found with no guards on rotating hazards. Place guards on rotating machinery to satisfaction of CG MI
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2017
Resolved
All wiring must be properly supported. Wiring near exhaust fans on both fans on both port and starboard E/R ventilation found not supported. Repair to satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 December 2017
Resolved
Starboard generator found with exhaust leak. Locate and repair leak to satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 December 2017
Resolved
Lube oil filters on port and starboard generators found with substantial leaks. Correct to the satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 December 2017
Resolved
Fire main discharge hose on fire pump found with substantial leak. Replace hose.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 December 2017
Resolved
Vessel must undergo an annual inspection within 3 months before or after it anniversary date. Vessel failed to conduct annaul inspection inside of required time frame.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2017
Construction/Loadline › Structures › Door
Issued 15 September 2016
Resolved
Water tight door between port and stbd engine room will not close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew fixed water tight door so that it closes and is water tight.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Seal
Issued 15 September 2016
Resolved
Both port and STBD prime movers on the generators need to have their real seals replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Company had service tech come out and inspect prime movers. It was found that the rear seals did not need to be replaced. All sat.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 15 September 2016
Resolved
Windings on both Port and STBD generators are covered with oil and need to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew cleaned winding on both generators.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 September 2016
Resolved
Exhaust fan in engine room is covered in oil and needs to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Vessel crew cleaned exhaust fan.
Engineering › Fuel Oil Service System › Hose
Issued 15 September 2016
Resolved
Fuel hose on STBD generator needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Vessel crew replaced fuel hose.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 15 September 2016
Resolved
Gauge panel needs to be bolted back in place
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 21 September 2016
Resolution: vessel's crew re bolted gauge panel back in place.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 September 2016
Resolved
Battery boxes in engine room had excessive water in the bottom of them
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew removed water from battery box.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2016
Resolved
Cable on 02 deck needs to be made up to the overhead at egress point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew made up cable run to overhead.
Lifesaving › Lifejacket/PFD (Type III) › Lights
Issued 15 September 2016
Resolved
Provide lights on PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew mounted lights on PFD's.
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 15 September 2016
Resolved
PFD's need to be marked with the vessel's name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 21 September 2016
Resolution: Vessel's crew stenciled PFD's with vessel's name.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 September 2016
Resolved
Emergency light on STBD side of pilothouse is broken and hanging by it's wires.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2016
Resolved 21 September 2016
Resolution: Emergency light was replaced with and is mounted properly.
Lifesaving › Lifefloat › Float-free Link
Issued 10 October 2014
Resolved
All 3 life floats did not have the proper float-free link installed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2014
Resolution: Vessel installed proper float-free links.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 October 2014
Resolved
All 3 life floats had the incorrect length of line (6ft) from the life float to the water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 13 October 2014
Resolution: Vessel installed the correct length of line from the life float to the water light.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 19 July 2012
Resolved
Crew berthing room #3, rope ladder installed. Vessel shall remove and install proper ladder.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 7 August 2012
Resolution: Verified rope ladder removed and proper ladder installed for emergency exit.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 July 2012
Resolved
Bridge depth sounder inoperative. Vessel shall repair to original condition and demonstrate to marine inspector.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 7 August 2012
Resolution: Verified bridge depth sounder operational.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 July 2012
Resolved
Port fuel tank leaking. Vessel shall repair to original condition and demonstrate to marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2012
Resolution: Verified port fuel tank repaired.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 19 July 2012
Resolved
Port/Stbd generators need to be cleaned and serviced to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 7 August 2012
Resolution: Verified Port/Stbd generators cleaned.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 26 August 2011
Resolved
General Alarm, PA, and nav equipment not working when Emergency power tested. Third party working on emergency power source during inspection. Vsl must show proper operation of battery back-up for GA, PA & nav equip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2011
Resolution: Witnessed proper operation of battery back-up for GA, PA & nav equip.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 August 2011
Resolved
Bilge alarms not properly working. Electrical systems being worked on during inspection. Vsl must show proper operation of all bilge alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2011
Resolution: Witnessed proper operation of bilge alarms
Stability › Watertight Integrity › General
Issued 26 August 2011
Resolved
Watertight door indicator alarms not working properly. Show proper operation of indicators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2011
Resolution: Witnessed proper operation of all watertight door indicators.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 26 August 2011
Resolved
Annual Automation test was being conducted during inspection but was not completed prior to departure of [name withheld] test results shall be made available for review to attending CG MI.
Action required: 705 - Other - as specified
Resolved 1 September 2011
Resolution: Reviewed sat annual automation test results.
Communications › Audible Communications › Bell
Issued 28 November 2007
Resolved
Provide Audible and Visual indicator for Phone in Engine Rooms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 4 December 2007
Resolution: Audible and Visual indicator installed and working correctly.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 November 2007
Resolved
Demonstarte that all doors required to be claosed while underway are closed and the Engines can operate. Found no positive ventialtion provided and that Exhaust ventilation was, all below deck doors left opened to keep engines running.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 4 December 2007
Resolution: Installed additional ventilation to allow doors to be kept closed while at sea.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 28 November 2007
Resolved
Current installation has the Fire "Pull Stations" being used as the General Alarm. Install additional Pull stations as required during New Construction in the Galley and at all Accomdation levels.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 10 November 2008
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 November 2007
Resolved
Install Depth Sounder.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 10 November 2008
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 28 November 2007
Resolved
Provide Navigation Light panel iaw 46 CFR 111.75-17.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 30 May 2008
Resolution: As installed, navigation lights meet 111.75-17 (d) and nav rules.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 28 November 2007
Resolved
Provide information and Worksheet for Master to safely determine Stability of vessel in any condition of Loading.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 4 December 2007
Resolution: Master can safely determine the Stability of the vessel via a worksheet.