← All vessels
CAPRICORNUS LEADER
CAPRICORNUS LEADER is a 2004 freight ship. The Coast Guard has recorded 25 inspections since 2004, most recently in January 2026, along with 10 deficiencies and 1 operational control.
Records from 2004 to 2026. Most recent: inspection, 14 January 2026.
- Built
- 2004
- Last inspected
- 14 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9283863 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2816
722885
Flag
SINGAPORE
—
Maury page id
psix-722885
Inspections, by type
…with no type recorded4
Years with a record
15 calendar years (2004–2026)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it18557 - Convention (Subpart B), Net Ton
20120 - Dead Weight, Ton
38562 - Displacement, Ton
61854 - Convention (Subpart B), Gross Ton
20120 - Dead Weight, Ton
38562 - Displacement, Ton
61854 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
14 January 2026
PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296441
25 June 2025
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8163042
15 December 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047607
25 November 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8037763
26 March 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7883234
11 September 2023
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7789232
18 September 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7571796
3 August 2022
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7522095
7 December 2021
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7363532
6 August 2020
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7025212
24 October 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6567105
19 October 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6564248
18 July 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6483624
19 September 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6269660
13 July 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5939511
11 July 2008
MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3264543
2 February 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2866273
26 October 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2809007
2 May 2006
MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2638609
3 August 2005
In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2450468
17 April 2005
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2335672
17 April 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2335686
16 April 2005
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2335153
4 October 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2206963
3 October 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2214292
Deficiency record · 10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2025
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECT WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD.
PSCO OBSERVED EMERGENCY LIGHTING, CARGO LIGHTING AND SMOKE DETECTORS IMPROPER AFFIXMENT TO VESSEL.
74 SOLAS (04) I/11(a)
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 December 2024
Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allow exhaust ventilation and closure of ventilation dampers. Crew was not able to close dampers in engine room via local controls. PSCO observed excessive rust causing louvers to be stuck in place.
74 SOLAS (14 Cons.) II-2 / 5.2.2.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 December 2024
Resolved
Means shall be provided to control leaks of flammable liquids... and the ignitability of combustible materials shall be restricted. PSCO observed oil-soaked lagging in the vicinity of Generator #1 and Main Engine.
74 SOLAS (14 Cons.) II-2/ 4.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 November 2024
Resolved
The company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Part 5, section 9/3 of vessel SMS specifies procedures for periodic checks of machinery. Deficiencies 2-7 provide objective evidence that these checks have not been conducted.74 SOLAS (2020) IX/3.1 & ISM Code 10.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2024
Resolved
After survery of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey, without the sanction of the Administration. Oil supply pipe had external damage to the exterior layer. 74 SOLAS (2020) 1/II (b)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2024
Resolved
The ignitability of combustible materials shall be restricted. Seal on hydraulic steering system had excessive leak into drip tray. Crew rectified while on board. Repaired and operationally tested. 74 SOLAS (2004) II-2/4.1.3
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. Refrigeration unit in CO2 room has rotating belt without personnel guard in front to prevent inadvertent contact. 74 SOLAS (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2024
Resolved
The ignitability of combustible materials shall be restricted. Fuel transfer piping lagging saturated. 74 SOLAS (2004) II-2/4.1.3
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 25 November 2024
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. The sides and the rear and, where necessary, the front of switchboard shall be suitably guarded. Multiple switchboard door latches not secured in ECR. 74 SOLAS (2004) II-1/45.2
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 25 November 2024
Resolved
Every ship of 100 gross tonnage and every ship which is certified to carry 15 or more persons, and fixed or floating platforms shall carry a garbage management plan which the crew shall follow. Old batteries were left in the battery room rather than stored in garbage room. Crew rectified by moving into adequate receptable in garbage room. MARPOL (2017 Cons.) V/10.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.