Records from 2018 to 2025. Most recent: inspection, 13 May 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)37.0 ft × 13.0 ft × 5.4 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2004
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
13 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8133715
13 May 2025
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8133716
26 June 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7943119
4 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7803430
11 July 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7739435
23 May 2023
Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7695633
30 March 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7417728
8 July 2021
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7249817
4 May 2021
Annual Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7194801
27 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7030966
17 June 2020
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6984209
8 June 2020
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6971327
14 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6939096
7 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6680847
16 April 2019
Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6665725
19 June 2018
COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6449587
12 May 2018
Simplified Stability Test
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6415470
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. On-board submersible bilge pumps do not meet the UL1113 requirement.
46 CFR 182.520(e)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 June 2025
Resolved
Rigid nonmetallic materials (plastic) may be used only non-vital systems...port and stbd raw water cooling system (vital system) has sections with rigid plastic piping, which is only allowed on non-vital systems.
Flexible non metallic hoses and fittings shall conform to the SAE J1942 and J1475 specifications.
46 CFR 182.720
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 June 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Fwd deck railing is not stable due to missing rail stanchion base screws.
46 CFR 177.900B
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be in compliance with § 181.420 of this
part. Fireboy signal wire is exposed due to cracked insulation, possibly causing main engine to not turn on. Repair to original end perform test of fireboay shut down of engine with a marine inspector present.
46 CFR 181.400B2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 18 June 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an
abandon ship or man overboard drill be held under simulated emergency conditions specified by the
inspector. Man overboard was not effective, and shall be completed again with a marine inspector present.
46 CFR 176.808G
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 June 2025
Resolved
Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. Ensure all vital flex hoses are properly clamped.
46 CFR 182.410D
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 June 2025
Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage. Engine room flexible hoses are not protected from mechanical damage.
46 CFR 182.720E3
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 13 May 2025
No resolution recorded
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission's National Call Center—[phone withheld]—or from its forms contractor. Update Radiotelephony certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 July 2023
Resolved
Vessel required to posses valid COD, Owner stated that the file had been overlooked and was in processing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
Electrical breaker and power distribution shall be maintained to minimize accidental electrical shock. Breaker switch found with disconnected wires that were attached to live power source.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2018
Resolved
Fireboy needs to be properly serviced prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2018
Resolved 25 June 2018
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 June 2018
Resolved
The vessel needs a documentation of certification before sailing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 August 2018
Resolved 25 June 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 June 2018
Resolved
Provide a valid FCC radio safety
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 25 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 June 2018
Resolved
Provide fire dampers of ventilation covers for the engineroom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 28 June 2018