MAURY USCG vessel records Sign in
← All vessels

CHIEF

CHIEF is a 2004 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2004, most recently in July 2026, along with 13 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 2 July 2026.

Built
2004
Last inspected
2 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN9146
722922
Flag
UNITED STATES
367314340
Maury page id
psix-722922

Inspections, by type

…with no type recorded2
Years with a record 19 calendar years (2004–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
ITC tonnagegross 341 / net 102
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN9146MMSI 367314340 · active · compulsorily equipped · granted 13 July 2023, expires 13 July 2033
WDD9641MMSI 367314340 · cancelled · compulsorily equipped · granted 19 July 2017, cancelled 10 July 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDC2097MMSI 366987870 · expired · compulsorily equipped · granted 3 November 2004, cancelled 3 January 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

2 July 2026 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8426059
20 May 2026 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8377397
26 August 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8192098
22 May 2025 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8141304
30 October 2024 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8027405
3 October 2024 Annual Inspection · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7995211
12 September 2023 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7774524
1 May 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7679053
23 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7144731
6 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6922001
29 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6697826
20 May 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6688395
17 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6428069
9 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6410306
4 May 2017 Hull Examination · Administrative Inspection · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6139082
30 January 2017 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6079958
11 February 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5813237
7 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4851671
14 May 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4311580
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200252
15 February 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3945266
30 December 2009 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3656457
12 May 2009 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3473298
24 January 2008 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3135400
27 March 2007 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2896260
13 February 2006 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2584248
14 July 2005 Type not recorded
No type recorded · Violation Case Coordination Center · Activity 2426133
21 June 2005 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 2398141
4 October 2004 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2213264

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 October 2024 Resolved
A vessel must comply with the structural design requirements for aluminum hull vessels. Vessel forepeak was found with the following structural deficiencies listed a) through e): a) Cracked weld on longitudinal deck stringer, third from port, in vicinity of the stem. b) Cracked weld on port outboard longitudinal deck stringer forward of swash bulkhead. c) Cracked weld and frame on port side shell longitudinal stiffener, seventh from the top. d) Cracked weld on port side shell longitudinal stiffener at the swash bulkhead, seventh frame from the top. e) Cracked weld on port side shell longitudinal stiffener at the swash bulkhead, eighth frame from the top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 30 October 2024
Resolution: Received evidence of satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 October 2024 Resolved
Life floats must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. Vessels life floats were missing spacers between the stacked life floats. Place spacers as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 17 October 2024
Resolution: Received evidence of compliance.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 March 2020 Resolved
Vessel was missing a CO2 placard on the engine room WTD. Stating "When Alarm sounds-vacate at once. Carbon Dioxide being released"
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 March 2020
Resolved 12 March 2020
Resolution: Vsl will order a placard and place it on the WTD in accordance with 46 CFR 185.612 (b) VSL procured a new placard and provided evidence.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 May 2018 Resolved
Emergency light at the rear main deck exit from the cabin is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2018
Resolved 9 May 2018
Resolution: Changed bulb. Corrected on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 9 May 2018 Resolved
Fuel flexible hose is deteriorated and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2018
Resolved 17 May 2018
Resolution: Replaced existing fuel hose with a new approved hose.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2018 Resolved
Three-way piping for cooling system is cracked and leaking, which needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2018
Resolved 17 May 2018
Resolution: Replaced three-way metallic pipe splitter with a new one. All sat.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 7 May 2014 Resolved
Emergency lighting along the line of escape to all spaces below the main deck was not adequate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2014
Resolution: Emergency lights is adequate for a safe escape in all spaces below the main deck.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 7 May 2014 Resolved
Rudder angle indictor was not working in proper operation. Indicator would got all the way to 40 starboard but only 20 port.
Due 21 May 2014
Resolved 9 May 2014
Resolution: Rudder angle indictor is operating properly. Indicator now goes from 30 starboard to 30 port.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 7 May 2014 Resolved
Vessel needs to update the EAP phone numbers to working numbers.
Action required: 705 - Other - as specified
Resolved 12 May 2014
Resolution: Vessel updated the EAP phone numbers to working numbers.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 7 May 2014 Resolved
Vessel has submitted and received the EPA VGP NOI however, vessel has not been keeping logs IAW this program. Logs will need to be inspected at next annual inspection to ensure compliance.
Action required: 705 - Other - as specified
Resolved 15 May 2015
Resolution: VGP was current no logs are required.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 13 February 2006 Resolved
Provide written attestation of generator overspeed trips.
Due 15 March 2006
Resolved 15 February 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 13 February 2006 Resolved
Provide written attestation of MDE shutdowns/alarms.
Due 15 March 2006
Resolved 15 February 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 October 2004 Resolved
Provide compass deviation table.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 15 February 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.