MAURY USCG vessel records
← All vessels

COOL CORAL CAT

COOL CORAL CAT is a 2004 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in November 2025, along with 19 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 6 November 2025.

Built
2004
Last inspected
6 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 November 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM8259
723598
Flag
UNITED STATES
Maury page id
psix-723598

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS, INC · TARPON SPRINGS, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Net Ton
11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

6 November 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8264129
21 October 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8240340
22 October 2024 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7995094
22 August 2024 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7986602
22 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853903
1 November 2023 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7817901
20 October 2022 DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7580779
14 June 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7477400
17 February 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7397644
1 December 2021 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7360402
15 January 2021 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7125097
7 January 2021 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7121251
14 November 2019 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination · COE-Dockside
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6855822
9 January 2019 Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6663347
4 January 2018 Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6584981
1 November 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6519032
6 December 2016 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6072973

Deficiency record · 19

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 November 2025 Resolved
Distress Signals container needs to be properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 October 2025 Resolved
Repair 5 areas with gel coat and FRP repairs. West system will be used on FRP repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 22 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2024 Resolved
Each portable fire extinguisher on a vessel must be of an appoved type. Fire extinguisher located at helm is missing annual inspection sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2024 Resolved
The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Buckets need to be labeled correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 22 October 2024
Resolution: Bucket have been correctly labeled.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 October 2024 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. Install alarm in FWD STBD compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2024
Resolved 13 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to marine inspector that cause has been repaired and repairs are satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2024
Resolution: Repower completed and sea trials conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 January 2024 Resolved
VHF radio Safety Certificate had expired. Must renew VHF radio Safety Certificate. 47 CFR 13
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2024
Resolved 9 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 February 2022 Resolved
Vessel failed to have annual inspection down within the 6 month window. Vessel must conduct annual inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2022
Resolution: Conducted annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2021 Resolved
Vessel failed to have its 2 yr drydock inspection completed by NOV 30th, 2021. Vessel must have drydock inspection and complete any repairs prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2021
Resolution: Completed Credit Drydock Inspection
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 January 2021 Resolved
Your stability letter dated NOV 24th 2004, shows passenger weight was 165 lbs used to determine the max passenger count. The weight now used to determine max passenger count. is 185 lbs. You need to conduct a new stability test using the 185 lbs per person. Until you conduct a new stability test, your max passenger count is 43 passengers and 2 crew. You have 30 days to decide what type of stability test you want to do. Simplified stability test with Coast Guard, or hire a Naval Architect to conduct a dead weight or incline survey witness by the Coast Guard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2021
Resolved 18 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 January 2021 Resolved
No visual indicators at helm station for automatic bilge pumps to indicate when they are running. Must install visual indicators on helm station for each automatic bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 21 April 2021
Resolution: Received video of automatic bilge lights coming on when pump is running.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2019 Resolved
4 adult life jackets are wasted. And must be renewed. Passenger count is reduced to not more than 47 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: 4 new life jackets were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2019 Resolved
Life floats need new paint, name and capacity on both sides, and name on paddles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: Life floats were repainted and stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2019 Resolved
Life ring grablines are wasted. Renew life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: Life ring was renewed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 November 2019 Resolved
Update charts, light list, and coast pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: All navigation pubs were renewed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 November 2019 Resolved
Lifesaving systems, and drill logs must be properly filled out.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: New logs were provided and are being utilized.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 December 2016 Resolved
Vessel COD is expired and must be renewed prior to any operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: New document was expedited, and is now onboard.
Lifesaving › Lifefloat › Netting
Issued 6 December 2016 Resolved
Life float on Port side has damaged netting, and failing grablines. repair or renew.
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 17 January 2017
Resolution: New netting and grablines were installed and sat.
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 December 2016 Resolved
STBD life float needs new paint and reflective material. Repair or Renew.
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 17 January 2017
Resolution: Life float was painted and new tape was installed. All sat.

Ownership record