MAURY USCG vessel records
← All vessels

WONDER AVIOR

WONDER AVIOR is a 2004 tank ship. The Coast Guard has recorded 2 inspections in 2022, along with 1 deficiency.

Records in 2022. Most recent: inspection, 12 August 2022.

Built
2004
Last inspected
12 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9250543
V7A4764
723766
Flag
MARSHALL ISLANDS
Maury page id
psix-723766

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 1 calendar year (2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it32824 - Convention (Subpart B), Net Ton
122954 - Displacement, Ton
106162 - Dead Weight, Ton
57062 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

12 August 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7531494
9 May 2022 COC-TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7433542

Deficiency record · 1

09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 May 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons. PSCO oberved significant steam leak on supply valve from boiler #1. 74SOLAS(04)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2022
Resolution: Received class report attesting to repairs made to supply valve from #1 boiler.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.