15 July 2025
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8186469
21 July 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7507997
25 June 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6986477
15 November 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6843721
29 August 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5986183
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 July 2022
Resolved
Ships shall be provided with independently driven fire pumps as follows: Cargo ships of 1,000 GT and upwards: at least two. PSCO observed only one fire pump.
74 SOLAS (2004 cons. ed) II-2 / Reg 10.2.2.2
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: A new pump was placed in service and tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 July 2022
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the doors shall be self-closing and be capable of closing with an angle of inclination up to 3.5 degrees opposing closure. PSCO observed 01 non-operational self closing door into steering gear compartent.
74 SOLAS (2004 cons. ed.) II-2 / Reg 9.4.1.1.4.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: The latch for the fire door was replaced and tested.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 21 July 2022
Resolved
The master, owner, operator or a vessel must properly maintain BWMS in accordance with all manufacturers specifications. Vessel BWTS was not operational at time of the exam. Vessel must not discharge untreated ballast water within 200 nm of shore.
33 CFR 151.2025
40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 September 2022
Resolved 15 July 2025
Resolution: Due to elapsed time and the nature of the deficiency, the 40c for the inoperable ballast system have been cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 July 2022
Resolved
Except as otherwise stated, the normal equipment of every lifeboat shall consist of: a first-aid outfit in a waterproof case capabel of being closed tightly after use. PSCO observed first aid kit on both lifeboats stored well above maximum 25 degrees C.
74 SOLAS (2014 cons. ed.) III / Reg 34
LSA Code 4.4.8.20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 15 July 2025
Resolution: Due to elapsed time and the nature of the deficiency, the 50a for stowage of the first aid kit has been cleared.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2022
Resolved
For this purpose, following functional requirements shall be met: means of control for flammable liquids in space shall be provided. PSCO observed paint stored above water sprinkler system in paint locker.
74 SOLAS (2004 cons. ed.) II-2 / Reg 5.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 July 2022
Resolution: Moved paint to below sprinkler
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 25 June 2020
Resolved
33 CFR 151.2025(a)(1) - Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into US waters. PSCO observed the BWMS to be inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 June 2020
Resolved 26 June 2020
Resolution: Vessel supplied a satisfactory service report for the BWTS.