BARRY is a 2004 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in May 2019, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2019. Most recent: operational control imposed, 11 May 2019.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it14444 - Convention (Subpart B), Net Ton 41748 - Dead Weight, Metric Ton 57251 - Displacement, Metric Ton 35881 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
11 May 2019Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6681684
9 May 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6680618
20 March 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6646083
12 March 2019Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6640650
11 March 2019PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6635472
11 March 2019Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6649334
28 October 2017Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6296805
23 October 2017Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292966
29 August 2017PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6245929
22 June 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6183467
11 April 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6121943
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2019Resolved
13199 - Other Machinery - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed two fuel oil lines leaking on # 2 generator prior to the injectors. Rectify deficiency prior to operating # 2 generator. 74 SOLAS (2014) II-2/4.1.1 50 ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 April 2019
Resolved 20 March 2019
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Fuel lines were dismantled, cleaned and replaced, class noted no leak detected.
Engineering › Fuel Oil Service System › Pump
Issued 29 August 2017Resolved
0750-Fire Prevention- Means shall be provided to control leaks of flammable liquids. PSCO observed Excessive fuel oil leaks IWO: #1,2,4 MDE fuel pumps, #1,#2,#3,#4 SSG Fuel pumps, DO fuel filters, HFO transfer pump strainer, and sludge transfer valve. 74 SOLAS (09 CONS) II-2 4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2017
Resolution: Received, reviewed and accepted class report NOS 1700420 from loyds register stating the deficiency was rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2017
Resolution: Received, reviewed and accepted class report NOS 1700420 from loyds register stating the deficiency was rectified.
Engineering › Pressure Vessel › Piping
Issued 29 August 2017Resolved
1499- Other. The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed control air leak to #6 MDE fuel pump. 74 SOLAS (04 CONS) II-1 26.1 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 October 2017
Resolution: PSC NOLA received a class report from Lloyd's Register of Shipping satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 August 2017Resolved
0799- Other fire fighting equipment. The construction of doors and door frames in "A" class division shall provide resistance to fire as well as to the passage of smoke and flame equivalent to the bulkheads in which the door is situated. PSCO observed A-60 fire door to engine room holed. 74 SOLAS (09 Cons) II-2 9.4.1.1.2 40a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 October 2017
Resolution: PSC NOLA recieved a class report from Lloyd's register satisfying the requirement
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 29 August 2017Resolved
1499-Other (Prop and Machinery)- The condition of the ship and its equipment shall be maintained after survey to ensure ship is fit to proceed to sea. PSCO observed DO drain valve gagged open and serving as feed valve to pump. 74 SOLAS (14 CONS) I-11 40(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 23 October 2017
Resolution: PSC NOLA received a class report from Lloyd's Register of Shipping satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.