Records from 1992 to 2016. Most recent: inspection, 28 January 2016.
Inspection history · 23
28 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5805191
24 July 2009
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544652
31 January 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2864659
17 November 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2826146
8 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2784825
10 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2742900
7 August 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2739344
12 January 2005
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2268802
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961044
18 July 2002
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1648743
31 July 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 292428
3 July 2001
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1069366
4 March 1996
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 388879
3 April 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 40404
30 January 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 374771
26 October 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 489517
28 January 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 669179
29 December 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 26428
15 December 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 669176
2 November 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 840662
15 October 1993
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1149804
15 September 1992
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 31157
2 May 1992
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 164899
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 August 2006
Resolved
Magnetic Compass not illuminated as required under 33 CFR 164.72
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Magntic Compass now illuminated
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 August 2006
Resolved
White stern light not working as required under 33usc2023(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Stern light now working
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 August 2006
Resolved
Hailing Port not displayed on stern as required under 46 CFR 67.123
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Hailing port now displayed
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 August 2006
Resolved
Replace support bracket on #2 fuel oil shut off assembly, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Bracket replaced and secure
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 August 2006
Resolved
Remote Fuel Oil Shut Off Valves must be marked with operation indicators as required under 46 CFR 27.207
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Remote fuel oil shut off valves properly marked
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 7 August 2006
Resolved
Install Flame screen on #1 Port fuel tank vent
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Flame screen installed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 7 August 2006
Resolved
Provide proof that portable B-V fire extinguisher meets USCG specifications as required under 46 CFR 27.211
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: B-V fire extinguisher meets USCG specifications
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2006
Resolved
Repair Guard on forward generator as required under 33 CFR 150.113
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Guard now repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2006
Resolved
Place cover on electrical box on stern generator, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 8 September 2006
Resolution: Cover now on electrical box
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2006
Resolved
Install Guard over light in laundry room, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 August 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 August 2006
Resolved
Remove excess oil and fuel from bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2006
Resolved 8 August 2006
Resolution: All fuel, oil and Water was removed from the bilges.
Unknown
Issued 15 October 1993
Resolved
PROVIDE OIL TRANSFER PROCEDURES (33 CFR 155.720) AS REQUIRED BY 33 CFR 155.740.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993