Records from 2004 to 2006. Most recent: inspection, 16 March 2006.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
16 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2603742
31 January 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2581603
29 January 2006
Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2575902
18 January 2005
Construction Oversight
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2276641
8 October 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2216782
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 January 2006
Resolved
Provide copy of Navigation Rules.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date.
[name withheld]
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 January 2006
Resolved
Provide operating instructions for the emergency generator fixed fire extinguishing system per 46 CFR 76.15-1.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2006
Communications › Audible Communications › Bell
Issued 29 January 2006
Resolved
Label all General alarms and strobes in the engineroom and egen space.
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date.
[name withheld]
Fire Fighting › Structural - Horizontal Zones › General
Issued 29 January 2006
Resolved
Clear all Debris and loose gear from egress routes 46 CFR 72.10
Action required: 705 - Other - as specified
Resolved 30 January 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2006
Resolved
Plug or install vent damper in EOS head 46 CFR 76.15-35, or as an option re-submit CO2 calc's for Engineroom to include the EOS.
Condition: Placed in Improper Service
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this Date.
[name withheld]
Fire Fighting › Fire Hydrants › Condition
Issued 29 January 2006
Resolved
Replace broken door handle for cabinet of Fire station NO. 11.
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date.
[name withheld]
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2006
Resolved
Install Globe on the light fixture in the Beer Cooler.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date.
[name withheld]
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2006
Resolved
Provide main lighting fixture approvals for the casino deck chandelier in accordance with Sub J.
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date, viewed UL approval.
[name withheld]
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 29 January 2006
Resolved
Correct all stray current problems on main switchboard, and e-bus.
Condition: Placed in Improper Service
Due 1 March 2006
Resolved 16 March 2006
Resolution: Sighted this date.
[name withheld]