Records from 2005 to 2025. Most recent: inspection, 5 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
5 November 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8264555
12 August 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8161486
12 November 2024
Deficiency Check · Plan Review "T" Boat · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027926
30 January 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7858134
28 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7830727
30 January 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629631
3 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443436
9 November 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7348338
14 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7175040
5 March 2020
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6921512
16 September 2019
Damage Survey · Administrative Inspection · Deficiency Check · Deadweight Survey · Drydock Exam · In-Service Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6813441
25 January 2007
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2861509
11 January 2006
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2564706
4 November 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2528528
10 February 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2289707
3 February 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2286048
17 January 2005
COI Inspection · Construction Oversight
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2276018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 December 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of vessel accessible to passengers. Vessel needs railing or suitable alternative installed out port/stbd side of bow were passengers are allowed. Vessel has 30 days to rectify (26Jan25). To allow passengers on the forward deck, the vessel must include missing railing in passenger safety brief, have crew member on the forward deck anytime a passenger is on the forward deck, and have a suitable rope guard in place. 46CFR177.900(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2025
Resolved 15 January 2025
Resolution: Vessel installed railings on forward bow in way of areas with passenger access to satisfaction of attending MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 November 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of vessel accessible to passengers. Vessel needs railing or suitable alternative installed out port/stbd side of bow were passengers are allowed. Install prior to allowing passengers on forward deck while vessel is underway. 46CFR177.900(a)
Action required: 705 - Other - as specified
Resolved 26 December 2024
Resolution: Reissued def with new requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 November 2024
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. 47CFR80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2024
Resolution: Vessel provided copy of valid Birdge-to-bridge certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 January 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. MI found 02 orange hand flares were missing. Owner had spare orange hand flares in the office and put them on-board prior to MI's departure.
Action required: 10 - Deficiency Rectified
Due 30 January 2024
Resolved 30 January 2024
Resolution: Owner had spare orange hand flares in the office and put them on-board prior to MI's departure.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 January 2024
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI pulled on attached line and it broke. Owner had spare life float in the office and replaced the broken one on-board prior to MI's departure.
Action required: 10 - Deficiency Rectified
Due 30 January 2024
Resolved 30 January 2024
Resolution: Owner had spare life float in the office and replaced the broken one on-board prior to MI's departure.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI found on of the bilge high level alarm was not sounding at the operating station. Crewmember removed the wire from the bus bar, cleaned it and reinstalled. Performed an operational test, test SAT.
Action required: 10 - Deficiency Rectified
Due 30 January 2024
Resolved 30 January 2024
Resolution: Crewmember removed the wire from the bus bar, cleaned it and reinstalled. Performed an operational test, test SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 May 2022
Resolved
Vessel operators found to be missing FCC Marine Operators Permit. Provide proof of license.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 24 May 2022
Resolution: POC provided proof of FCC certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2022
Resolved
All vessels holding a Certificate of Inspection must undergo an annual inspection with the three (03) months before and after each anniversary date. Vessel's required annual exam window lapsed on 15 APR 2022. Vessel operator was informed by the USCG Marine Inspector on required inspection window for vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 May 2022
Resolved 6 May 2022
Resolution: Completed annual exam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021
Resolved
Ring Buoy waterlight was not operational during inspection. Repair or replace in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 26 April 2021
Resolution: Received documentation of def corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Install and terminate cable splice within electrical junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 26 April 2021
Resolution: Received documentation of def corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2021
Resolved
Port Bilge pump seal found leaking during inspection.
Repair or replace seal in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 1 May 2021
Resolution: Received documentation of def corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 April 2021
Resolved
Port & STBD Propulsion engine belt guards were not in place during inspection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 26 April 2021
Resolution: Received documentation of def corrected.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 January 2006
Resolved
Provide proof of pre-employment testing and random testing enrollment for the crew involved in safety sensitive positions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 January 2006
Resolved
Service and inspect all portable fire extinguisher with an expiration date of over a year on an approved servicing facility.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Lifesaving › Lifefloat › Serviceable
Issued 17 January 2005
Resolved
Provide manufacturers instructions for onboard maintenance iaw 46 CFR 185.702.
Condition: Unknown
Due 18 February 2005
Resolved 20 January 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 January 2005
Resolved
Post emergency instructions, emergency broadcast placard, lifejacket donning placard, marpol placard, and fire protection equipment instructions
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2005
Documentation › Logs/Records › Logbook (official)
Issued 17 January 2005
Resolved
Provide navigation pubs iaw 46 CFR 184.420.
Condition: Unknown
Due 18 February 2005
Resolved 21 February 2005
Documentation › Certificates/Documents › FCC SSL
Issued 17 January 2005
Resolved
Provide FCC station license.
Condition: Unknown
Due 18 February 2005
Resolved 6 May 2005
Construction/Loadline › Structures › Trunk
Issued 17 January 2005
Resolved
Make engine room hatches watertight.
Condition: Improper Installation
Due 18 February 2005
Resolved 21 February 2005
Fire Fighting › Nozzles › Number
Issued 17 January 2005
Resolved
Provide fire nozzle
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2005
Engineering › Bilge Water Management System › Piping
Issued 17 January 2005
Resolved
Provide a means to drain any watertight compartment iaw 46 CFR 182.500 (a) or submit for MSC's approval stability calculations for special consideration due to high degree of subdivision and small buoyancy compartments. (As per converstaion with [name withheld], Plans submited to MSC for review, extended one month from 03/18/2005 to 04/18/05. JEM)
Condition: Improper Installation
Due 18 March 2005
Resolved 4 November 2005