MAURY USCG vessel records Sign in
← All vessels

SEAWAYS ARIADMAR

SEAWAYS ARIADMAR is a 2004 tank ship. The Coast Guard has recorded 34 inspections since 2004, most recently in April 2019, along with 7 deficiencies and 4 operational controls.

Records from 2004 to 2019. Most recent: inspection, 4 April 2019.

Built
2004
Last inspected
4 April 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9273624 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
726949
Flag
MARSHALL ISLANDS
—
Maury page id
psix-726949

Inspections, by type

…with no type recorded11
Years with a record 13 calendar years (2004–2019)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11781 - Convention (Subpart B), Net Ton
55157 - Displacement, Ton
44999 - Dead Weight, Ton
30018 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENERGY 6502 Tank Barge · MISLE 52128 · 22 January 2005 · activity 2501774

Inspection history · 34

4 April 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6652012
3 April 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6655414
17 November 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6582470
13 June 2018 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6442955
13 June 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6446034
4 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6380155
23 March 2018 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam · COE-Dockside
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6374232
10 March 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6101269
27 July 2016 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5953062
16 June 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4890695
16 June 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4890702
26 March 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4823176
23 December 2011 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4213386
10 August 2011 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4111425
21 December 2010 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3914504
10 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3888756
26 October 2010 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3879097
8 October 2010 COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3861232
9 March 2010 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3691721
23 December 2009 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3656281
8 December 2008 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3376134
6 November 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3093754
4 October 2007 Loadline Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3072953
26 June 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2693225
16 June 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2681442
14 January 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2566963
25 October 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2568457
17 October 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2516123
18 August 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2464766
1 July 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2410230
26 March 2005 COC-CHEM Renew
Type not classified · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2318741
22 January 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2501774
25 October 2004 COC-TVE Renew
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2227498
25 October 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2227691

Deficiency record · 7

Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 23 March 2018 Resolved
9800 - Other(Clearly hazardous) - Means shall be provided to control leaks of flammable liquids. Number 2 and 3 generators had fuel leaks on the high pressure fuel line assembly before the injector. 74SOLAS(04CONS)CHII-2/REG4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 April 2018
Resolution: Received Lloyds Register report attesting to the rectification of leaking injectors.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 June 2014 Resolved
On 12 June 2014, OVERSEAS ARIADMAR transited through the Western Alaska COTP Zone without a valid Geographic Specific Appendix for Western Alaska in its Vessel Response Plan.
Due 16 June 2015
Resolved 6 February 2015
Resolution: Mailed company an NOV
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 26 March 2014 Resolved
0720; Foreign Flag product carrier required to have fixed foam systems and carry polar solvents shall have alcohol foams. Vessel is authorized to carry polar solvents in accordance with Certificate of Fitness but the vessel is not equipped with alcohol foam. 46CFR34.20-5 (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2014
Resolution: Received confirmation that the foam on board is alcohol resistant.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 26 March 2014 Resolved
1705; Every ship of 150 G/T an above certified to carry NLS in bulk shall carry onboard a Shipboard Marine Pollution Emergency Plan. Such plan shall include the list of authorities or persons to be contacted in the event of NLS pollution incident. The vessel did not have the correct contact information for local authorities in the plan or on the emergency contact list provided by the company.(10c)
Action required: 705 - Other - as specified
Due 26 March 2014
Resolved 26 March 2014
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Third Mate.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 March 2014 Resolved
0155; The shipboard Vessel Response Plan must include a list of local port contact. VRP does not have correct contact information for local authorities including local COTP. Company did not provide correct contact information. (10c)
Action required: 705 - Other - as specified
Resolved 26 March 2014
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Third Mate.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 26 March 2014 Resolved
2510; Any vessel equipped with ballast water tanks that operates in waters of the United States must maintain a Ballast Water Plan that has been developed specifically for the vessel and that will allow those responsible for implementation to understand. The PSCO found incomplete and poorly organized plan that the crew did not understand, 33 CFR 151.2050(g). (10c)
Action required: 705 - Other - as specified
Resolved 26 March 2014
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Third Mate.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 November 2007 Resolved
Vessel requested an LOD for secondary radar. Vessel is required to provide a tech report proving radar has been repaired prior to departure from St. Croix.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2007
Resolution: Received tech report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.