MAURY USCG vessel records Sign in
← All vessels

ANGELA

ANGELA is a 2004 freight ship. The Coast Guard has recorded 21 inspections since 2004, most recently in March 2019, along with 8 deficiencies and 4 operational controls.

Records from 2004 to 2019. Most recent: operational control imposed, 3 March 2019.

Built
2004
Last inspected
3 March 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9274915 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
727106
Flag
PANAMA
—
Maury page id
psix-727106

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2004–2019)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17927 - Convention (Subpart B), Net Ton
52571 - Dead Weight, Ton
60772 - Displacement, Ton
30064 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

3 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6635507
2 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6448322
19 March 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5836392
15 August 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4948025
17 August 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4116438
15 August 2011 ISPS I Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4116500
7 February 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3936453
28 October 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3352472
13 October 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3343208
13 August 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3297684
12 August 2008 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3290801
26 June 2008 Random ISPS/MTSA-No PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3249052
12 April 2008 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3182608
8 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3144390
20 July 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2995376
10 April 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2905016
24 August 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2758744
8 June 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2674046
23 May 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2656975
4 November 2004 ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2228997
26 October 2004 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2229603

Deficiency record · 8

Navigation › Piloting/Steering › Gyro Compass
Issued 15 August 2014 Resolved
1540 - Gyro compass - Vessel reported inoperable gyro compass. Provide technician's report attesting to the proper operation of the gyrocompass.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2014
Resolved 21 August 2014
Resolution: Received tech report from Mackey attesting to the proper operation of the equipment.
Electrical › Electric Generation Source (service) › Switch
Issued 13 October 2008 Resolved
Fire damage was discovered in the ships laundry room during the PSC examination. Vessel must make repairs to the electrical wiring and installations to the satisfaction of Class prior to departure form LA. Provide copy of Class Survey to the USCG. 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2008
Resolution: Class report was received attesting to the insulation and electrical wiring being renewed to the satisfaction of class.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 13 October 2008 Resolved
Provide class report attesting to the suitability for the service of the temporary repairs in the main engine fresh water cooling system. The cooling system has three soft patches, several recent repairs, and signs of new leaks beginning. Provide report prior to departure. 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2008
Resolution: Class report was received attesting to the replacing of the soft pipes with correct replacement of the failed piping.
Engineering › Diesel Engine (auxiliary) › Blower, Centrifugal
Issued 13 October 2008 Resolved
Auxiliary blower exhaust pipe has a leak above the boiler as indicated by severe soot coating. Provide class report attesting to the repairs prior to next US port after sailing foriegn. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2008
Resolution: satisfactory class report received
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 August 2008 Resolved
During PCS exam, crew did not demonstrate competency in operation of OWS and oil content meter. Prove proper operation of OWS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Received class report.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 12 April 2008 Resolved
Cylinder cooling jacket o-rings on cylinders #5 & #6 worn/wasted. Vessel to prove proper operation of main engine in all modes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 14 April 2008
Resolution: Received satisfactory report of survey by Class.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 23 May 2006 Resolved
The embarkation ladder side ropes are deteriorated at the ships attachment point.
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 8 June 2006
Resolution: Received a class report stating the embarkation ladder was repaired.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 4 November 2004 Resolved
Provide Current Navigation Rules, U. S. Inland.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2004
Resolution: Received faxed receipt.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.