LADY LIBERTY

LADY LIBERTY is a 2004 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2005, most recently in March 2026, along with 35 deficiencies and 1 operational control.

Records from 2005 to 2026. Most recent: inspection, 25 March 2026.

Built
2004
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5384
727304
Flag
UNITED STATES
367040240 (licence lapsed)
Maury page id
psix-727304

Inspections, by type

Years with a record 17 calendar years (2005–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.0 ft × 5.0 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderANDERSEN BOAT WORKS INC · SAUGATUCK, MI, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portRIDGEDALE, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Net Ton
36 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5384MMSI 367040240 · expired · compulsorily equipped · granted 7 May 2005, cancelled 11 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 28

25 March 2026 Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8340773
26 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8097183
25 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7884564
17 January 2024 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7846618
14 March 2023 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7639476
29 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7401913
9 July 2021 Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7253357
31 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7135215
28 August 2020 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7131807
22 June 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6986970
21 October 2019 Hull Examination · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6838669
11 February 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6623997
30 April 2018 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6403868
30 January 2017 Construction Oversight · Deficiency Check · Internal Structural Exam · Plan Review "T" Boat · Administrative Inspection · Drydock Exam · Examination of Repairs · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6089873
31 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5892584
21 March 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5852537
13 July 2012 Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4383147
21 July 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4089411
11 August 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3298080
27 February 2008 Drydock Extension · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3154736
10 September 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3061791
6 April 2007 Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2914464
19 January 2007 Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2861115
17 January 2007 Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857267
17 August 2006 Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2751045
10 May 2006 Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2645906
23 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2607935
11 April 2005 MARPOL Annex V Examination · Initial Certification · Plan Review "T" Boat · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2331557

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020 Resolved
Ensure all firefighting equipment is serviced. Annual inspection / service not completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2020
Resolution: Satisfactory proof of testing was provided. Inspectors witnessed servicing and testing of installed engine room firefighting system (fireboy).
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 June 2020 Resolved
Prove receipt of required destress signals. Flares are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2020
Resolution: New distress signals were procured and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019 Resolved
The vessels fire pump suffered a fracture in the pump housing caused by freezing temperatures. Replace fire pump housing as original and prove proper operation of the fire pump to the attending USCG Marine Inspector. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019 Resolved
Vessels fire main piping ruptured in the steering compartment caused by freezing temperatures. Provide repair proposal to the satisfaction of the USCG Marine Inspector. Make repairs to the fire main piping as originally designed using same materials. Prove the fire main is leak free and repairs have been completed to the satisfaction of the attending USCG Marine Inspector. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019 Resolved
Vessels bilge piping ruptured in the #3 space (stores) caused by freezing temperatures. Provide repair proposal to the satisfaction of the USCG Marine Inspector. Make repairs to the bilge piping as originally designed using same materials. Prove proper repairs & operation of all bilge suctions to the satisfaction of the attending USCG Marine Inspector. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2019 Resolved
Prove proper operation of both propulsion engines and generators prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 February 2019 Resolved
Prove proper operation of lazarette bilge level alarm indicator light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2019
Resolved 26 March 2019
Resolution: Received video evidence that alarm indicator light is functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2019 Resolved
Secure loose fuel pipe between transfer pump and generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2019
Resolved 15 March 2019
Resolution: Received photographic evidence of repairs via email.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 May 2018 Resolved
Vessel's fixed FireBoy system protecting the engine room was past due on service date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2018
Resolution: Vessel owner/operator dispatched for fire servicing company to service system the following morning (5/24). This was verified SAT on the morning of 5/24.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2018 Resolved
During the inspection, it was discovered that the audible bilge alarm for the storage tank space was inoperable (visual was operable).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 30 May 2018
Resolution: Received video proof that storage tank space audible (and visual) bilge alarm were functional.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 May 2018 Resolved
PFD storage box marking were not accurate to the size and number of PFDs actually in the box. All required PFDs were onboard, however markings on boxes were not accurate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 24 May 2018
Resolution: Vessel owner/operator created new signage for all boxes/lockers in which PFDs were stowed. These new markings accurately indicated size and number of PFDs.
Engineering › Thrusters › Tunnel
Issued 20 June 2017 Resolved
Submit amended plans to the Marine Safety Center that include the "as built" arrangement of the thruster installation & any additional measures necessary to return the lost strength to the thruster tunnel area. Once plans are approved, affect any repairs and structural reinforcement required by approved amended plans to the satisfaction of attending Coast Guard marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2017
Resolution: Amended plans have been submitted to the Marine Safety Center as required. Marine inspector attended vessel to verify installation and repairs IAW plans.
Stability › Incline Test › General
Issued 20 June 2017 Resolved
Submit amended stability calculations to the Marine Safety Center to account for any additional weight added by the amended installation plans or additional structural reinforcement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2017
Resolution: Amended stability calculations were sumbitted to the Marine Safety Center to account for additional weight added by installation plans and structural reinforcement. MSC found the aggregate weight fell below 2% lightship displacement.
Engineering › Thrusters › Tunnel
Issued 14 June 2017 Resolved
Submit "as built" plans and structural analysis for stern thruster installation to MSC or Sector UMR for approval.
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 20 June 2017
Resolution: 835 invalidated by issuance of no sail 835
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 May 2017 Resolved
Make repairs to incomplete/fractured welds/frames in the lazerette IWO the newly installed stern thruster.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 20 June 2017
Resolution: Repairs were not affected. There are concerns with thruster installation and structural integrity IWO of new installation. Original CG-835 retracted and a new CG-835 issued for revised plans, repairs and installation.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 May 2017 Resolved
Provide current proof that the vessel is registered with NVDC.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2017
Resolved 11 May 2017
Resolution: Received confirmation that COD application was submitted.
Documentation › Certificates/Documents › Stability Letter
Issued 17 May 2016 Resolved
Vessel's Stability Letter does not accurately reflect the number of fixed ballast ingots located in forward half of vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 31 May 2016
Resolution: Received phone call from Naval Architect requesting info on stability letter issue in order to provide letter to MSC requesting amendment.
Communications › Audible Communications › SPD (Other)
Issued 17 May 2016 Resolved
Vessel is not equipped with fixed two way comms from steering space to operating station for auxiliary steering operations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 2 June 2016
Resolution: Received email verification and photos identifying that two-comms have been installed in the lazarrette compartment.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 September 2007 Resolved
Install metallic valve for through hull overboard discharge located in tank space prior to completion of credit drydock 31Mar08.
Due 31 March 2008
Resolved 11 March 2008
Resolution: Received photos via e-mail that metallic valve for through hull overboard discharge was installed. Deficiency cleared.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007 Resolved
Install a metallic valve for through hull overboard discharge located in tank space starboard side.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 10 September 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007 Resolved
Install a metallic valve for through hull overboard discharge in galley.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 10 September 2007
Stability › Intact Righting Energy › General
Issued 6 April 2007 Resolved
Secure lead ballast to fixed position located in galley bilge and tank space bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2006 Resolved
Install battery in waterlight for ring buoy.
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 11 October 2006
Resolution: Battery installed in waterlight.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 August 2006 Resolved
Perform annual servicing on all portable fire extinguishers and fixed extinguishing system installed in engine room, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2006
Resolved 18 August 2006
Resolution: Received fax receipt of annual servicing of portable fire extinguishers and fixed CO2 extinguishing system in the engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2006 Resolved
Place wire splice for air conditioning equipment located in fuel tank space in an enclosure.
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 11 October 2006
Resolution: Wire splice located in enclosure.
Stability › Severe Wind/Roll › General
Issued 17 August 2006 Resolved
Vessel has a temporary canopy installed on the upper deck. This canopy was not included in the calculations for the simplified stability test conducted on 19 APRIL 2005. Canopy on upper deck must be removed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2006
Resolution: Received statement dated 13 OCT 06 confirming canopy has been removed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 April 2005 Resolved
Provide method for passenger count.
Due 20 May 2005
Resolved 26 May 2005
Resolution: Vessel O/O will leave the passenger count with the Worlds Fair Marina Dock Master.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 April 2005 Resolved
Install light on magnetic compass.
Due 20 May 2005
Resolved 15 May 2005
Resolution: Light installed in compass.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 11 April 2005 Resolved
Provide method for Passenger Safety Orientation.
Due 20 May 2005
Resolved 26 May 2005
Resolution: Vessel O/O has submitted copy of passenger safety orientation which he will state over the internal sound system.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 April 2005 Resolved
Provide additional lifejackets for crew.
Due 20 May 2005
Resolved 15 May 2005
Resolution: Additional lifejackets were provided.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 April 2005 Resolved
Provide lifejacket donning placard.
Due 20 May 2005
Resolved 15 May 2005
Resolution: Lifejacket donning placards posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2005 Resolved
Provide waterlight meeting 46 CFR 161.010
Due 20 May 2005
Resolved 26 May 2005
Resolution: Proper waterlight purchased and installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 April 2005 Resolved
Provide sea rails for cooking surface.
Due 20 May 2005
Resolved 26 May 2005
Resolution: Sea rails were designed and installed around heating surface.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 April 2005 Resolved
Provide documentation of supervisory training.
Due 20 May 2005
Resolved 26 May 2005
Resolution: Recieved fax documenting proof of completion of supervisory training.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 April 2005 Resolved
Provide FCC Marine Operators Permit for Master.
Due 20 May 2005
Resolved 15 July 2005
Resolution: VEIFIED OPERATOR PERMIT VIA PHONE CONVERSATION WITH O/O

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.