← All vessels
LADY LIBERTY
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named LADY LIBERTY
LADY LIBERTY is a 2004 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2005, most recently in March 2026, along with 35 deficiencies and 1 operational control.
Records from 2005 to 2026. Most recent: inspection, 25 March 2026.
- Built
- 2004
- Last inspected
- 25 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1164317
WDC5384
727304
Flag
UNITED STATES
367040240 (licence lapsed)
Maury page id
psix-727304
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 18.0 ft × 5.0 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderANDERSEN BOAT WORKS INC · SAUGATUCK, MI, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portRIDGEDALE, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Net Ton
36 - Simplified, Gross Ton
36 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC5384MMSI 367040240 · expired · compulsorily equipped · granted 7 May 2005, cancelled 11 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
25 March 2026
Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8340773
26 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8097183
25 March 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7884564
17 January 2024
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7846618
14 March 2023
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7639476
29 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7401913
9 July 2021
Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7253357
31 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7135215
28 August 2020
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7131807
22 June 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6986970
21 October 2019
Hull Examination · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6838669
11 February 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6623997
30 April 2018
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6403868
30 January 2017
Construction Oversight · Deficiency Check · Internal Structural Exam · Plan Review "T" Boat · Administrative Inspection · Drydock Exam · Examination of Repairs · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6089873
31 May 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5892584
21 March 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5852537
13 July 2012
Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4383147
21 July 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4089411
11 August 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3298080
27 February 2008
Drydock Extension · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3154736
10 September 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3061791
6 April 2007
Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2914464
19 January 2007
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2861115
17 January 2007
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857267
17 August 2006
Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2751045
10 May 2006
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2645906
23 March 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2607935
11 April 2005
MARPOL Annex V Examination · Initial Certification · Plan Review "T" Boat · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2331557
Deficiency record · 35
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
Ensure all firefighting equipment is serviced. Annual inspection / service not completed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 June 2020
Resolved
Prove receipt of required destress signals. Flares are expired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019
Resolved
The vessels fire pump suffered a fracture in the pump housing caused by freezing temperatures. Replace fire pump housing as original and prove proper operation of the fire pump to the attending USCG Marine Inspector. Prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019
Resolved
Vessels fire main piping ruptured in the steering compartment caused by freezing temperatures. Provide repair proposal to the satisfaction of the USCG Marine Inspector. Make repairs to the fire main piping as originally designed using same materials. Prove the fire main is leak free and repairs have been completed to the satisfaction of the attending USCG Marine Inspector. Prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019
Resolved
Vessels bilge piping ruptured in the #3 space (stores) caused by freezing temperatures. Provide repair proposal to the satisfaction of the USCG Marine Inspector. Make repairs to the bilge piping as originally designed using same materials. Prove proper repairs & operation of all bilge suctions to the satisfaction of the attending USCG Marine Inspector. Prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2019
Resolved
Prove proper operation of both propulsion engines and
generators prior to carrying passengers.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 February 2019
Resolved
Prove proper operation of lazarette bilge level alarm indicator light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2019
Resolved
Secure loose fuel pipe between transfer pump and generator.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 May 2018
Resolved
Vessel's fixed FireBoy system protecting the engine room was past due on service date.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2018
Resolved
During the inspection, it was discovered that the audible bilge alarm for the storage tank space was inoperable (visual was operable).
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 May 2018
Resolved
PFD storage box marking were not accurate to the size and number of PFDs actually in the box. All required PFDs were onboard, however markings on boxes were not accurate.
Engineering › Thrusters › Tunnel
Issued 20 June 2017
Resolved
Submit amended plans to the Marine Safety Center that include the "as built" arrangement of the thruster installation & any additional measures necessary to return the lost strength to the thruster tunnel area. Once plans are approved, affect any repairs and structural reinforcement required by approved amended plans to the satisfaction of attending Coast Guard marine inspector.
Stability › Incline Test › General
Issued 20 June 2017
Resolved
Submit amended stability calculations to the Marine Safety Center to account for any additional weight added by the amended installation plans or additional structural reinforcement.
Engineering › Thrusters › Tunnel
Issued 14 June 2017
Resolved
Submit "as built" plans and structural analysis for stern thruster installation to MSC or Sector UMR for approval.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 May 2017
Resolved
Make repairs to incomplete/fractured welds/frames in the lazerette IWO the newly installed stern thruster.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 May 2017
Resolved
Provide current proof that the vessel is registered with NVDC.
Documentation › Certificates/Documents › Stability Letter
Issued 17 May 2016
Resolved
Vessel's Stability Letter does not accurately reflect the number of fixed ballast ingots located in forward half of vessel.
Communications › Audible Communications › SPD (Other)
Issued 17 May 2016
Resolved
Vessel is not equipped with fixed two way comms from steering space to operating station for auxiliary steering operations.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 September 2007
Resolved
Install metallic valve for through hull overboard discharge located in tank space prior to completion of credit drydock 31Mar08.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007
Resolved
Install a metallic valve for through hull overboard discharge located in tank space starboard side.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 April 2007
Resolved
Install a metallic valve for through hull overboard discharge in galley.
Stability › Intact Righting Energy › General
Issued 6 April 2007
Resolved
Secure lead ballast to fixed position located in galley bilge and tank space bilge.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2006
Resolved
Install battery in waterlight for ring buoy.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 August 2006
Resolved
Perform annual servicing on all portable fire extinguishers and fixed extinguishing system installed in engine room, prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2006
Resolved
Place wire splice for air conditioning equipment located in fuel tank space in an enclosure.
Stability › Severe Wind/Roll › General
Issued 17 August 2006
Resolved
Vessel has a temporary canopy installed on the upper deck. This canopy was not included in the calculations for the simplified stability test conducted on 19 APRIL 2005. Canopy on upper deck must be removed prior to carrying passengers.
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 April 2005
Resolved
Provide method for passenger count.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 April 2005
Resolved
Install light on magnetic compass.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 11 April 2005
Resolved
Provide method for Passenger Safety Orientation.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 April 2005
Resolved
Provide additional lifejackets for crew.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 April 2005
Resolved
Provide lifejacket donning placard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2005
Resolved
Provide waterlight meeting 46 CFR 161.010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 April 2005
Resolved
Provide sea rails for cooking surface.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 April 2005
Resolved
Provide documentation of supervisory training.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 April 2005
Resolved
Provide FCC Marine Operators Permit for Master.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National