MAURY USCG vessel records Sign in
← All vessels

MEGANISI

MEGANISI is a 2004 tank ship. The Coast Guard has recorded 33 inspections since 2004, most recently in February 2019, along with 7 deficiencies and 8 operational controls.

Records from 2004 to 2019. Most recent: operational control imposed, 20 February 2019.

Built
2004
Last inspected
20 February 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9286023 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
727318
Flag
UNITED STATES
—
Maury page id
psix-727318

Inspections, by type

…with no type recorded14
Years with a record 12 calendar years (2004–2019)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it20970 - Convention (Subpart B), Net Ton
86152 - Displacement, Metric Ton
72515 - Dead Weight, Metric Ton
41526 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CREOLE CRUSADER Towing Vessel · MISLE 2317 · 20 February 2019 · activity 6633223GONSOULIN 540 Tank Barge · MISLE 1265084 · 20 February 2019 · activity 6633223

Inspection history · 33

20 February 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628904
20 February 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6633223
21 November 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6582729
18 October 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6563626
29 September 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6551421
22 December 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324888
31 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6256163
31 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6256466
17 July 2017 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6205643
13 November 2016 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6035575
10 November 2015 COE-Dockside · COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5726657
28 October 2014 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5006211
25 March 2014 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4820599
24 March 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4821609
22 November 2010 ISPS III Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896168
14 February 2010 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679858
6 February 2010 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676414
21 November 2008 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3360764
2 November 2007 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3083987
21 September 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3063122
13 February 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2871553
29 July 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2729122
10 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2646349
13 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2601553
2 December 2005 MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2543795
8 August 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2456129
6 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2460776
19 January 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2277568
4 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2253243
2 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2251732
2 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2233384
31 October 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2234006
28 October 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2230067

Deficiency record · 7

Engineering › Fuel Oil Service System › Flange
Issued 13 November 2016 Resolved
0750-Fire Fighting- To prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leak on the fuel injectors of all 6 cylinders on the MDE. SOLAS 74 (14) II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Received documentation from [name withheld] attesting to the satisfactory repairs to main engine.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 13 November 2016 Resolved
0750-Fire Fighting- To prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leak on the fuel oil transfer system pump with appx 15gal of fuel oil found in installed containment. SOLAS 74 (14) II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Received documentation from [name withheld] attesting to the satisfactory repairs to fuel oil transfer system.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 13 November 2016 Resolved
1799-MARPOL other- The condition of ship and its equipment shall be maintained to conform w/the provisions of the present convention to ensure the ship in all respects will remain fit to proceed to sea without unreasonable threat to the marine environment. PSCO observed that ship's cargo pump master emergency shutdown did not function from cargo control rm. MARPOL 6.4.1. Prior to discharge a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Received documentation from [name withheld] attesting to the satisfactory operation of the cargo pump master emergency shutdown.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 28 October 2014 Resolved
1870-Tanker(Special Requirements)- Provisions shall be made to guard against liquid rising in the vent system. This shall be accomplished by high-level alarms or other means, together with independent gauging devices and cargo filliong procedures. Overfill visual and audible alarms were not operational on deck for all cargo tanks. 74 SOLAS(09) II-2/11.6.3
Due 28 October 2014
Resolved 28 October 2014
Resolution: 10c- Vessel elcectrician discovered blown fuse for deck indicators, replaced fuse system now operating as designed.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 28 October 2014 Resolved
0750-Fire Prevention-In order to achieve the fire safety objectives set out in para.1, the following requirements are embodied in the regulations of this chapter, restricted use of combustible materials. PSCO observed 170 gal. of paint stored on the upper deck of the cargo pump room, a location not designated as a storage location of flammable liquids on the fire control plan. SOLAS (09) II-2/2.2
Action required: 705 - Other - as specified
Due 11 November 2014
Resolved 31 October 2014
Resolution: Received, reviewed and accepted masters statement. Vessel disposed of excess paint and provided receipt.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 2 December 2005 Resolved
Noted a missing cap on electrical connection to a fluorescent light at the last ladder at the bottom of the pump room. Without this cap, wires were visible through the short length of conduit piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2005
Resolution: Cap provided.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 28 October 2004 Resolved
Vessel does not have suitable span gas or testing equipment for portable LEL meters. Provide proof of receipt of suitable gas and equipment IAW SOLAS II/2 59.5.
Due 5 November 2004
Resolved 4 November 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.