← All vessels
LILA HONG KONG
LILA HONG KONG is a 2003 tank ship. The Coast Guard has recorded 25 inspections since 2004, most recently in April 2023, along with 10 deficiencies and 3 operational controls, 1 with no removal date recorded.
Records from 2004 to 2023. Most recent: inspection, 6 April 2023.
- Built
- 2003
- Last inspected
- 6 April 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9259721 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5TV4
727347
Flag
LIBERIA
—
Maury page id
psix-727347
Inspections, by type
…with no type recorded11
Years with a record
9 calendar years (2004–2023)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it52153 - Convention (Subpart B), Net Ton
159149 - Dead Weight, Metric Ton
185978 - Displacement, Metric Ton
84855 - Convention (Subpart B), Gross Ton
159149 - Dead Weight, Metric Ton
185978 - Displacement, Metric Ton
84855 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
6 April 2023
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7662547
1 April 2023
COC-TVE Renew · PSC B · COE-Administrative
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7658983
11 June 2019
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706762
12 July 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6475350
11 July 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6477654
19 September 2017
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6270437
13 April 2017
COC-TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6113822
7 June 2012
ISPS II Exam · COC-TVE Renew · Ballast Water Examination · COE-Offshore
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4328966
29 December 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3385916
29 September 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3335204
26 April 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3192603
26 April 2008
MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3194147
13 April 2008
ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3183204
4 December 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3109378
15 July 2007
COC-TVE Annual · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2985949
14 July 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2998470
7 May 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2648920
1 May 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2637515
18 April 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2642200
28 March 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2612241
13 March 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2601605
23 February 2006
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2590257
9 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2238978
2 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2233386
29 October 2004
COC-TVE Renew · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2230304
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2019
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. fOR THIS PRURPOSE, THE FOLLOWING FUCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. ALL THREE OF THE SHIP'S CARGO PUMPS WERE DISCOVERED TO BE LEAKING FLAMMABLE LIQUIDS. 74SOLAS (14) II-2/4.1.1 60AC
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 11 June 2019
Resolved
THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. REMOTE OPERATION OF THE SHIP'S STEERING GEAR IN NON-FOLLOW UP MODE WAS DELAYED AND NOT OPERATING AS ORGINALLY INTENTED. 74SOLAS (14) 1/11a
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 June 2019
Resolved
OIL FUEL PIPES, WHICH, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE, SETTLING OR DAILY SERVICE TANK HAVING A CAPACITY OF 500L AND ABOVE SITUATED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE CONCERNED IN THE EVENT OF A FIRE OCCURRING IN THE SPACE WHICH SUCH TANKS ARE SITUATED. THE QUICK-CLOSING VALVE INTENTED TO BE OPERATED FROM OUTSIDE THE EMERGENCY GENERATOR ROOM WAS INOPERATIVE. 74 SOLAS (14) II-2/4.2.2.3.4 10C
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 June 2019
Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSC Examiner observed several openings being used to run cables through the purifier room, which could render the CO2 system ineffective.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2019
Resolved
On a tankship, each cargo tank must be equipped with an overfll device (including an independent audible or visible indicator for that tank) that meets the requirements for tank overfill alarms under 46CFR39.20-7(b)(2) and (3), and (d)(1) through (d)(4). The ship's audible and visible alarm intended to alert the crew of overfill of the ship's cargo tanks, were inoperative.
Construction/Loadline › Structures › Door
Issued 13 April 2008
Resolved
Access to the Emergency Fire Pump current configuration met security requirement, however means of access from outside was blocked. Access must be from both sides. SOLAS 74/78 Ch II-2 Reg 2.2.3.2.2 To the satisfaction of Class.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 15 July 2007
Resolved
The #1 inert gas blower fan transformer experienced an electrical fire during tests of the inert gas system alarms and shutdowns. the #1 IG blower is inoperative. The blower/transformer must be repaired to the satisfaction of class and the USCG prior to departure and prior to endorsement of the Certificate of Compliance.
Engineering › Steam System (auxiliary) › Valve
Issued 23 February 2006
Resolved
Vessel had a steam valve that was leaking steam. Valve is on the fuel oil heating system located in the engine room. Vessel was given to 3/23/2006 to fix or replace valve and provide report to local [name withheld] 74/78/2004/II-1 33.1
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 23 February 2006
Resolved
Vessel had malfunction on lowering cable on STBD side life boat. Cable broke during life boat drill and ships force could not correct problem on site. Vessel was given prior to departure and NLT 2/27/2006 to have repairs made and provide report to local [name withheld] 74/78/2004 III/16.2
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 29 October 2004
Resolved
Ship did not have 1" stud on all VCS flanges at manifolds. Prior to using ship's vapor collection system in the navigable waters of the United States, ship must meet the requirement in 46 CFR 39.20-1 (e). Provide report from certificating issuing authority to local OCMI once ship is in compliance with 46 CFR 39.20-1(e).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.