MAURY USCG vessel records Sign in
← All vessels

DANGERS PEARL

DANGERS PEARL is a 1988 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2005, most recently in April 2026, along with 46 deficiencies.

Records from 2005 to 2026. Most recent: inspection, 23 April 2026.

Built
1988
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM9726
727426
Flag
UNITED STATES
367739000
Maury page id
psix-727426

Inspections, by type

Years with a record 19 calendar years (2005–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 16.4 ft × 8.2 ft
Registered tonnagegross 28 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTREWORGY YACHTS INC · PALM COAST, FL, UNITED STATES · built 1988
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Faired Keel)
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Net Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9726MMSI 367739000 · active · compulsorily equipped · granted 10 May 2022, expires 10 May 2032 · licensed under a name not among this hull’s recorded names (not shown)
WDC9372MMSI 367739000 · cancelled · compulsorily equipped · granted 30 January 2016, cancelled 6 May 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

23 April 2026 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8350534
10 July 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8182543
7 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8130137
17 July 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7960221
26 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7796483
28 June 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7723563
5 December 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7604500
3 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7438381
17 November 2021 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7328529
28 April 2021 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7160459
10 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955227
27 December 2019 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6881030
4 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6802943
17 September 2019 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813866
24 April 2019 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6643003
7 May 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6407824
7 November 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6324010
14 June 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6175640
3 May 2017 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6142898
3 May 2016 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5867041
2 November 2015 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5762291
7 May 2014 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4879623
7 May 2012 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4304092
12 December 2011 Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4206508
7 December 2009 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3645894
7 May 2009 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3469399
13 May 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3205657
5 December 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3109867
17 May 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2933859
5 October 2005 Plan Review "T" Boat · Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2508330

Deficiency record · 46

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2026 Resolved
Provide and mark 2 additional Type I adult life jackets so there are a total of 40 on board. Vessel restricted to carrying 36 passengers.
Action required: 705 - Other - as specified
Resolved 23 April 2026
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022 Resolved
Provide the a valid Certificate of Documentation for change of ownership prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 May 2022 Resolved
Conduct a man overboard, emergency egress, and fire fighting drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022 Resolved
Provide Florida State Registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2020 Resolved
Install metal supports not more than 24 inches aparton electrical cable and wiring in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 7 August 2020
Resolution: Received e-mail from [name withheld] with photographs showing metal supports were installed on the electrical cable and wiring in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2020 Resolved
Clearly mark the stowage container and number of lifejackets stowed in the main cabin. Letters and numbers must be at least 2 inches high.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2020
Resolution: Received e-mail from [name withheld] with photographs showing their life jacket stowage location in the main cabin is clearly marked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 September 2019 Resolved
Waste receptacles must be constructed of non-combustible materials. Trash cans in heads are made of plastic. Provide non combustible waste receptacles any time they are used below the main deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019 Resolved
When a deck scuttle serves as a means of escape, it must be fitted with a hold back device to hold the scuttle in position. None of the emergency escapes have hold back devices. Provide hold back devices for the emergency escapes. Rectify deficiencies prior to the carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019 Resolved
Each ladder used as a means of escape must be mounted at least 7 inches from the nearest permanent object in back of the ladder. Rungs must be 16 inches in width and not more than 12 inches apart but no less than 4.5 inches apart. Vessel does not have adequate ladders for the emergency escapes for the forward berthing or the aft/crew berthing. Provide means of escape that are in compliance with regulations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019 Resolved
Means of escape must be adequately marked both inside and out. Escape hatches are not adequately marked. Ensure that hatches are marked with two inch lettering "Emergency Escape Keep Clear"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2019
Resolved 4 November 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 September 2019 Resolved
Each vessel shall have a suitable number of watchmen to ensure that patrols are conducted during night time, whether or not the vessel is underway, to guard against, and give alarm in case of , a fire, man overboard, or other dangerous situation. For these watchmen, provide a list of areas/ procedures to use while on watch. Additionally, provide an entry in the log for watch relief.
Action required: 705 - Other - as specified
Due 3 November 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 17 September 2019 Resolved
Each berth shall be constructed of wood, fiber reinforced plastic, or metal. One berth in the amidship berthing area is of a cot/hammock design. Provide plans for a berth that meets the above mentioned characteristics.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 4 November 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 September 2019 Resolved
On a vessel of more than 24 hours duration, pasengers shall don lifejackets and and go to the appropriate embarkation station. Ensure that emergency escape drills are conducted each time overnigh passengers are embarked to ensure their understanding of emergency escape routes. These drills should be logged in the ship's log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2019
Resolved 18 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019 Resolved
Provide a flammable storage locker with a 40B:C portable fire extinguisher mounted in the aft deck area for the storage of the diesel fuel can. Prior to use of compressor.
Action required: 705 - Other - as specified
Resolved 9 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 April 2019 Resolved
Install guard for the impeller pump pully on the engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 April 2019 Resolved
Install guard and warning sign on exhaust on compressor.
Action required: 705 - Other - as specified
Resolved 9 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 April 2019 Resolved
Install deck rails at 4 inch intervals due to operating as an excursion vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 April 2019 Resolved
Submit plans to for removal of sight glass or install of tanks connections that automatically close in the event of a rupture of the gauge or lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019 Resolved
Compressor must be secured to the deck to prevent movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2019 Resolved
Compressor battery must be in a battery box to prevent electrolyte spillage or objects from falling on terminal posts.
Action required: 705 - Other - as specified
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2019 Resolved
Replace SOLAS tape on both life floats, repair separated seam with appropriate material, re-attach float free link in a float free manner.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 April 2019 Resolved
First Aid kit is missing 100 aspirin tablets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 April 2019 Resolved
Vessel must have up to date publication on board. Light list was outdated and missing Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 April 2019 Resolved
Post life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 7 May 2018 Resolved
Hydro fixed fire extinguishing system cylinder or replace.
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 21 May 2018
Resolution: Cylinder hydrostatically tested.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018 Resolved
Provide complete first aid kit IAW 46CFR160.041 (ammonia inhalants).
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 21 May 2018
Resolution: Ammonia inhalants added to kit.
Engineering › Bilge Water Management System › Pump
Issued 3 May 2017 Resolved
Replace submersible electric bilge pump with pump that is UL listed or provide documentation that installed pumps are UL listed.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 May 2017
Resolution: New UL approved pumps installed.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 May 2017 Resolved
Provide documentation that smoke detectors are 217 UL listed or replace with UL listed detectors.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 3 May 2017
Resolution: Documentation provided to attest to UL approval.
Engineering › Bilge Water Management System › Piping
Issued 3 May 2017 Resolved
Replace bilge hoses with suitable/substantial construction, (Machinery space, shaft alley).
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 May 2017
Resolution: Bilge piping replaced with suitable piping.
Sail Rigging › Chainplates › Materials
Issued 2 November 2015 Resolved
Prepair STBD side main mast chain plates for visual inspection (bare metal).
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 3 November 2015
Resolution: Paint removed from chain plates and Inspector visually examined chain plate. All sat.
Construction/Loadline › Structures › Superstructure
Issued 12 December 2011 Resolved
KW01 Repair fractured weld on Foremast cap
Due 30 December 2011
Resolved 15 December 2011
Construction/Loadline › Structures › Superstructure
Issued 12 December 2011 Resolved
KW02 Repair fractured weld on main mast tang
Due 30 December 2011
Resolved 15 December 2011
Construction/Loadline › Structures › Superstructure
Issued 12 December 2011 Resolved
KW03 Repair staysail boom fractured weld on tang.
Due 30 December 2011
Resolved 19 December 2011
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2009 Resolved
must replace 03 worn zincs.
Due 21 December 2009
Resolved 15 December 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2009 Resolved
04 wires on vessel rigging above norseman fittings are cracked. Must replace all wire rigging to the satisfaction of attending marine inspector.
Due 21 December 2009
Resolved 15 December 2009
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 December 2009 Resolved
Replace worn cutless bearing.
Due 21 December 2009
Resolved 15 December 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 October 2005 Resolved
Properly post COI, Stability Letter and Emergency Instructions.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 October 2005 Resolved
Install horizontal rail courses IAW 46 CFR 177.900(g)(1)(ii).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2006
Documentation › Markings/Placards › Warning Signs
Issued 5 October 2005 Resolved
Mark emergency exits in way of aft berthing area and fwd V-berth on clearly visible part of interior.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2006
Communications › Visual Communication › Red Warning Signal
Issued 5 October 2005 Resolved
Install indicator light at operating station showing whether fwd watertight door is in open or closed position.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006
Lifesaving › Lifefloat › Serviceable
Issued 5 October 2005 Resolved
Provide spacers between lifefloats IAW 46 CFR 180.137(f).
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 24 May 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 October 2005 Resolved
Provide B-II fire extinguisher on deck.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 October 2005 Resolved
Station engine room vent covers permanently near engine room vents.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006
Stability › Watertight Integrity › General
Issued 5 October 2005 Resolved
Provide captive chain in way of anchor locker watertight hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2006
Resolved 24 May 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 October 2005 Resolved
Provide flashlight at operating station and at entrance to engine space IAW 46 CFR 183.430.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006
Communications › Audible Communications › SPD (Other)
Issued 5 October 2005 Resolved
Provide battery powered bullhorn on vessel.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 May 2006

Ownership record