Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
23 April 2026
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8350534
10 July 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8182543
7 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8130137
17 July 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7960221
26 September 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7796483
28 June 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7723563
5 December 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7604500
3 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7438381
17 November 2021
Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7328529
28 April 2021
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7160459
10 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955227
27 December 2019
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6881030
4 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6802943
17 September 2019
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813866
24 April 2019
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6643003
7 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6407824
7 November 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6324010
14 June 2017
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6175640
3 May 2017
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6142898
3 May 2016
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5867041
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2026
Resolved
Provide and mark 2 additional Type I adult life jackets so there are a total of 40 on board. Vessel restricted to carrying 36 passengers.
Action required: 705 - Other - as specified
Resolved 23 April 2026
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022
Resolved
Provide the a valid Certificate of Documentation for change of ownership prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 May 2022
Resolved
Conduct a man overboard, emergency egress, and fire fighting drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022
Resolved
Provide Florida State Registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2020
Resolved
Install metal supports not more than 24 inches aparton electrical cable and wiring in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 7 August 2020
Resolution: Received e-mail from [name withheld] with photographs showing metal supports were installed on the electrical cable and wiring in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2020
Resolved
Clearly mark the stowage container and number of lifejackets stowed in the main cabin. Letters and numbers must be at least 2 inches high.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2020
Resolution: Received e-mail from [name withheld] with photographs showing their life jacket stowage location in the main cabin is clearly marked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 September 2019
Resolved
Waste receptacles must be constructed of non-combustible materials. Trash cans in heads are made of plastic. Provide non combustible waste receptacles any time they are used below the main deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019
Resolved
When a deck scuttle serves as a means of escape, it must be fitted with a hold back device to hold the scuttle in position. None of the emergency escapes have hold back devices. Provide hold back devices for the emergency escapes. Rectify deficiencies prior to the carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019
Resolved
Each ladder used as a means of escape must be mounted at least 7 inches from the nearest permanent object in back of the ladder. Rungs must be 16 inches in width and not more than 12 inches apart but no less than 4.5 inches apart. Vessel does not have adequate ladders for the emergency escapes for the forward berthing or the aft/crew berthing. Provide means of escape that are in compliance with regulations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019
Resolved
Means of escape must be adequately marked both inside and out. Escape hatches are not adequately marked. Ensure that hatches are marked with two inch lettering "Emergency Escape Keep Clear"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2019
Resolved 4 November 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 September 2019
Resolved
Each vessel shall have a suitable number of watchmen to ensure that patrols are conducted during night time, whether or not the vessel is underway, to guard against, and give alarm in case of , a fire, man overboard, or other dangerous situation. For these watchmen, provide a list of areas/ procedures to use while on watch. Additionally, provide an entry in the log for watch relief.
Action required: 705 - Other - as specified
Due 3 November 2019
Resolved 4 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 17 September 2019
Resolved
Each berth shall be constructed of wood, fiber reinforced plastic, or metal. One berth in the amidship berthing area is of a cot/hammock design. Provide plans for a berth that meets the above mentioned characteristics.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 4 November 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 September 2019
Resolved
On a vessel of more than 24 hours duration, pasengers shall don lifejackets and and go to the appropriate embarkation station. Ensure that emergency escape drills are conducted each time overnigh passengers are embarked to ensure their understanding of emergency escape routes. These drills should be logged in the ship's log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2019
Resolved 18 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019
Resolved
Provide a flammable storage locker with a 40B:C portable fire extinguisher mounted in the aft deck area for the storage of the diesel fuel can. Prior to use of compressor.
Action required: 705 - Other - as specified
Resolved 9 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 April 2019
Resolved
Install guard for the impeller pump pully on the engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 April 2019
Resolved
Install guard and warning sign on exhaust on compressor.
Action required: 705 - Other - as specified
Resolved 9 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 April 2019
Resolved
Install deck rails at 4 inch intervals due to operating as an excursion vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 April 2019
Resolved
Submit plans to for removal of sight glass or install of tanks connections that automatically close in the event of a rupture of the gauge or lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019
Resolved
Compressor must be secured to the deck to prevent movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2019
Resolved
Compressor battery must be in a battery box to prevent electrolyte spillage or objects from falling on terminal posts.
Action required: 705 - Other - as specified
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2019
Resolved
Replace SOLAS tape on both life floats, repair separated seam with appropriate material, re-attach float free link in a float free manner.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 April 2019
Resolved
First Aid kit is missing 100 aspirin tablets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 April 2019
Resolved
Vessel must have up to date publication on board. Light list was outdated and missing Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 April 2019
Resolved
Post life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2019
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 7 May 2018
Resolved
Hydro fixed fire extinguishing system cylinder or replace.
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 21 May 2018
Resolution: Cylinder hydrostatically tested.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018
Resolved
Provide complete first aid kit IAW 46CFR160.041 (ammonia inhalants).
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 21 May 2018
Resolution: Ammonia inhalants added to kit.
Engineering › Bilge Water Management System › Pump
Issued 3 May 2017
Resolved
Replace submersible electric bilge pump with pump that is UL listed or provide documentation that installed pumps are UL listed.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 May 2017
Resolution: New UL approved pumps installed.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 May 2017
Resolved
Provide documentation that smoke detectors are 217 UL listed or replace with UL listed detectors.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 3 May 2017
Resolution: Documentation provided to attest to UL approval.
Engineering › Bilge Water Management System › Piping
Issued 3 May 2017
Resolved
Replace bilge hoses with suitable/substantial construction, (Machinery space, shaft alley).
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 May 2017