Records from 2005 to 2008. Most recent: inspection, 17 November 2008.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
17 November 2008
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3364910
5 July 2007
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2983928
19 September 2006
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2793412
21 February 2006
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2589373
26 July 2005
Hull Examination · Initial Certification
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2435483
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2007
Resolved
Prove proper operation of the port bilge high level alarms prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2007
Resolved 19 July 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 July 2007
Resolved
Replace anchor light. Vessel is restricted to daylight operations only.
Due 5 July 2007
Resolved 19 July 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 July 2007
Resolved
Prove proper operation of the vessel's steering system.
Due 5 July 2007
Resolved 19 July 2007
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 5 July 2007
No resolution recorded
Provide servicing certificate for LP cooking system prior to next use.
Due 5 July 2007 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 26 July 2005
Resolved
Provide sound producing device.
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 26 July 2005
Engineering › Bilge Water Management System › Not Installed
Issued 26 July 2005
Resolved
Provide hand portable bilge pump.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 26 July 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 26 July 2005
Resolved
Post Emergency Broadcast Placard.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 26 July 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 26 July 2005
Resolved
Provide oil discharge placard.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 26 July 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 July 2005
Resolved
Provide lifejacket donning placards as required.
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 15 February 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 July 2005
Resolved
Provide "lockout" in way of MSD overboard discharge valves, port and starboard.
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 15 February 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 July 2005
Resolved
Provide flashlights at operating station and entrance to propulsion machinery space.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 26 July 2005